My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
222 W CASINO RD 2025-03-27
>
Address Records
>
W CASINO RD
>
222
>
222 W CASINO RD 2025-03-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2025 2:40:46 PM
Creation date
4/3/2023 8:04:28 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
222
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
952
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC DUCT SPECIFICATION <br />INSULATION <br />DUCT MATERIALS <br />FITTINGS <br />FLEX <br />CLEANLINESS DURING <br />(INDOOR, OUTDOOR) <br />SEISMIC <br />SEISMIC <br />DUCT SYSTEM <br />PRESSURE CLASS <br />SPECIFICATION <br />sPECIFCATIONz33113&z351oo <br />CONNECTION/FLEX DUCT SEAL CLASS <br />CONSTRUCTION <br />20181NT'LENERGY CODE C403.11.1 <br />LINING MATERIALS <br />CRITERIA <br />IMPORTANCE <br />NOTES <br />SPECIFICATION 233113 & 235100 <br />'DETERMINED BY CLIMATE ZONE & ASHRAE 90.1 TABLES 6.8.2 <br />FACTOR IP <br />& B-1 <br />HVAC SUPPLY <br />SMAGNA+1/2"OR+1'PRESSURE <br />GALVANIZED DUCT; GAUGE AND REINFORCEMENT SHALL BE <br />ELBOWS: PURCHASED ADJUSTABLE ELBOWS IN <br />12-FOOT MAX. LENGTH WITH NO OFFSETS; USE <br />SMACNA SEAL CLASS A, <br />-FOLLOW BASIC"LEVEL A'SMACNA <br />WITHIN CONDITIONED SPACE; R-33(<55F OR>105F) <br />LINING WHERE INDICATED ON THE PLANS <br />SEISMIC SUPPORT PER APPLICABLE CODE I <br />IP=1.0 <br />1,2,3,4,5 <br />SMACNA OR BETTER <br />ACCORDANCE WITH SMAGNA+I"STANDARDS <br />JPL OR EQUAL <br />PER 2015 SEC C4032.83 <br />LOCAL JURISDICTION, SEE MECHANICAL <br />LOW PRESSURE <br />NO PRESSURE TEST REQUIRED PER IEC G403.2.7 <br />WHEN NOT IN A CONDITIONED SPACE: RS WITH APPROVED VAPOR BARRIER <br />SEISMIC SHEET WHEN APPLICABLE. <br />IP=1.5 <br />RECTANGULAR MAY BE S+DRME <br />CL RADIUS OF 1.0 DIA ON DUCTS LARGER THAN 24" <br />(LAB PRESSURIZATION) <br />TERMINALS TO DIFFUSERS <br />WHEN OUTSIDE: R-8 EXTERIOR INSULATION WITH APPROVED VAPORIWEATHER <br />FAN COIL UNITS TO DIFFUSERS <br />ROUND MAY BE SNAPLOCK. <br />SPIN -IN IATTO BRANCHES OK <br />BARRIER <br />HEAT PUMPS TO DIFFUSERS <br />HVAC CA INTAKE <br />SMACNA 32" <br />GALVANIZED DUCT; GAUGE AND REINFORCEMENT SHALL BE <br />ELBOWS: CENTERLINE RADIUS OF 1.5 DIA OR MITERED <br />FLEX AT EQUIP CONNECTIONS TO COMPLY WITH <br />SMACNA SEAL CLASS LEVEL C <br />FOLLOW BASIC"LEVEL A'SMACNA <br />WITHIN CONDITIONED SPACE: R-7(LESS THAN 2800 CFM) <br />LINING WHERE INDICATED ON THE PLANS <br />SEISMIC SUPPORT PER APPLICABLE CODE <br />IP=1.0 <br />1,2,3,4,5 <br />SMACNA OR BETTER <br />90S WITH VANES OR PURCHASED ADJUSTABLE <br />SMACNA APPLICABLE PRESSURE CLASS <br />R4.4 per inch <br />LOCAL JURISDICTION. SEE MECHANICAL <br />LOUVERCANIPLENUMS <br />NO PRESSURE TEST REQUIRED PER IEC C403.2.7 <br />ELBOWS IN ACCORDANCE WITH SMACNA-1' <br />NOT WITHIN CONDITIONED SPACE: RS WITH APPROVED VAPOR BARRIER <br />SEISMIC SHEET WHEN APPLICABLE. <br />IP=1.5 <br />UPSTREAM OF MOTORIZED DAMPER <br />RECTANGULAR TO HAVE TOE CONNECTIONS <br />(LAB PRESSURIZATION) <br />CL RADIUS OF 1.0 DIA ON DUCTS LARGER THAN 24" DIA <br />OSA DUCT WI GREATER THAN 2800 OEM UPSTREAM OF MOTORIZED DAMPER SHALL <br />ROUND MAY BE SNAPLOCK <br />BE INSULATED TO BUILDING ENVELOPE R-VALUES <br />TAPS: CONICAL OR BOOT -STYLE <br />HVAC RETURN <br />SMACNA -112"OR-1'PRESSURE <br />GALVANIZED DUCT; GAUGE AND REINFORCEMENT SHALL BE <br />ELBOWS: CENTERLINE RADIUS OF 1.5 DIA OR MITERED <br />3-FOOT MAX. LENGTH WITH NO OFFSETS; USE <br />SMACNA SEAL CLASS LEVEL C <br />FOLLOW BASIC "LEVEL A'SMACNA <br />WITHIN CONDITIONED SPACE: R-3.3 <br />1'LINING ONLY WHERE INDICATED ON PLANS <br />SEISMIC SUPPORT PER APPLICABLE CODE/ <br />IP=1.0 <br />1. 2. 3. 4.5 <br />SMACNA OR BETTER <br />90S WITH VANES OR PURCHASED ADJUSTABLE <br />JPL OR EQUAL; <br />R4.4 per inch <br />LOCAL JURISDICTION. SEE MECHANICAL <br />LOW PRESSURE <br />NOTE: MCKINSTRY BUILDS ALL LOW PRESSURE DUCTWORK IN <br />ELBOWS IN ACCORDANCE WITH SMACNA+1' <br />WHEN NOT IN A CONDITIONED SPACE: R-6 WITH APPROVED VAPOR BARRIER <br />SEISMIC SHEET WHEN APPLICABLE. <br />IP=1.5 <br />ACCORDANCE WITH+1"SMACNA GUIDELINES TO MAXIMIZE <br />RECTANGULAR TO HAVE SBD CONNECTIONS, ROUND MAY BE SPRAT <br />FLEXAT EQUIP CONNECTIONS TO COMPLY WITH <br />(LAB PRESSURIZATION) <br />PRODUCTION EFFICIENCY <br />CL RADIUS OF 1.0 DIA ON DUCTS LARGER THAN 24"DIA <br />SMACNA APPLICABLE PRESSURE CLASS <br />WHEN OUTSIDE R-8 EXTERIOR INSULATION WITH APPROVED VAPORANEATHER <br />SNAP LOCK PIPE STANDARD <br />BARRIER <br />NO PRESSURE TEST REQUIRED PER IEC C403.2.7 <br />TAPS: CONICAL OR BOOT -STYLE <br />SPIN4N IATTO BRANCHES OR <br />HVAC EXHAUST <br />SMACNA -1l2"OR-1'PRESSURE <br />GALVANIZED DUCT; SEE SUBMITTAL FOR GAUGE AND <br />ELBOWS: PURCHASED ADJUSTABLE ELBOWS IN <br />12-FOOT MAX. LENGTH WITH <br />SMACNA SEAL CLASS LEVEL C <br />FOLLOW BASIC"LEVEL A'SMACNA <br />NOT REQUIRED <br />1'LINING ONLY WHERE INDICATED ON PLANS <br />SEISMIC SUPPORT PER APPLICABLE CODE <br />IP=1.0 <br />1,2,3, 4,5 <br />REINFORCEMENT. <br />ACCORDANCE WITH SMACNA-1'STANDARDS <br />NO OFFSETS; USE JPL OR EQUAL; <br />R4.4 per inch <br />LOCAL JURISDICTION. SEE MECHANICAL <br />LOW PRESSURE <br />NOTE: MCKINSTRY BUILDS ALL LOW PRESSURE DUCTWORK IN <br />SEISMIC SHEET WHEN APPLICABLE. <br />IP=1.5 <br />ACCORDANCE WITH+1'SMACNA GUIDELINES TO MAXIMIZE <br />RECTANGULAR MAY BE S+D, ROUND MAY BE SNAPLOCK. <br />CL RADIUS OF 1.0 DIA ON DUCTS LARGER THAN 24" <br />FLEX AT EQUIP CONNECTIONS <br />(LAB PRESSURIZATION, CHEMICAL STORAGE, <br />PRODUCTION EFFICIENCY <br />TO COMPLY WITH SMACNA <br />BATTERY, & REFRIGERATION EXHAUST) <br />SPIN -IN IATTO BRANCHES OK <br />APPLICABLE PRESSURE CLASS <br />NO PRESSURE TEST REQUIRED PER IEC C403.2.7 <br />BACKDRAFT DAMPERS <br />NIA <br />N/A <br />N/A <br />WA <br />PER APPLICABLE DUCT SYSTEM <br />PER APPLICABLE DUCT SYSTEM <br />NIA <br />HORIZOMAL MOUNT, VERTICAL AIRFLOW- <br />NIA <br />NIA <br />1,2,3 <br />LOW PRESSURE <br />GREENHECK BR-10 OR APPROVED <br />VERTICAL MOUNT, HORIZONTAL AIRFLOW - <br />GREENHECK BR-30 OR APPROVED <br />VOLUME DAMPERS <br />NIA <br />IN <br />N/A <br />NIA <br />PER APPLICABLE DUCT SYSTEM <br />PER APPLICABLE DUCT SYSTEM <br />NIA <br />SHOPFABRICATED PER SMACNA OR GREENHECK OR APPROVED <br />N/A <br />N/A <br />1,2,3 <br />VOLUME DAMPERS (REMOTE) <br />NIA <br />N/A <br />N/A <br />WA <br />PER APPLICABLE DUCT SYSTEM <br />PER APPLICABLE DUCT SYSTEM <br />NIA <br />SHOP FABRICATED PER SMACNA OR GREENHECK 9V RBDR50 OR <br />NIA <br />NIA <br />1,2,3 <br />APPROVED <br />NOTES. <br />1. ALL DUCTWORK TO BE FABRICATED IN ACCORDANCE WITH MCKINSTRY DUCT CONSTRUCTION STANDARDS / SUBMITTALS WHICH MEET OR EXCEED SMACNA GUIDELINES. <br />2. ALL DIMENSIONS SHOWN ON PLANS ARE INSIDE CLEAR DIMENSIONS. <br />3. THE MECHANICAL ENGINEER RESERVES THE RIGHT TO AUTHORIZE DEVIATIONS TO THESE STANDARDS TO ACCOMMODATE UNIQUE SITUATIONS AS APPLICABLE. <br />4. USE DOUBLE WIDTH VANES UNLESS OTHERWISE NOTED ON THE DRAWINGS. <br />5, USE OF DUCTWORK FOR TEMPORARY HEATING I CONDITIONING DURING CONSTRUCTION NOT ALLOWED WITHOUT SPECIAL APPROVAL BY THE ENGINEER. <br />MECHANICAL PIPE INSULATION SCHEDULE - WASHINGTON <br />ENERGY COOE: 2018 INTERNATIONAL ENERGY CODE WITH WASHINGTON AMENDMENTS TABLE C403.10.3 <br />SPECIFICATION: 230700 HVAC INSULATION <br />PIPING <br />SYSTEM <br />TEMP RANGE <br />(Deg F) <br />THERMAL COND. <br />MEAN RATING <br />TEMPERATURE <br />INSULATION <br />MATERIAL <br />NOTES <br />11" <br />1"TO<1-1/2" <br />1112'T04" <br />4"-8- <br />OVER 8" <br />HEATING WATER <br />141-200 <br />0,25-0.29 <br />125 <br />MPI <br />1.5 <br />1.5 <br />2.0 <br />2.0 <br />2.0 <br />1, 2, 3, 4, 5 <br />MPI: MINERAL WOOL PREFORMED PIPE INSULATION <br />GENERAL NOTES: <br />I.INSTALLATION OF INSULATION SHALL BE PER THE MIDWEST INSULATION CONTRACTOR'S ASSOCIATION (MICA) STANDARDS MANUAL AND MANUFACTURER'S REQUIREMENT. THE INSULATION CONTRACTOR SHALL PROVIDE INSTALLATION DETAILS IF REQUESTED BY THE ENGINEER <br />2. FOR FUTHER INFORMATION ON INSULATING SYSTEMS AND EQUIPMENT EITHER LISTED OR NOT LISTED, SEE SPECIFICATION SECTION 230700 -HVAC INSULATION'. <br />KEYNOTES: <br />1. FOR PIPING CLAMPED TO UNISTRUT SUPPORTS, UTILIZE RIGID INSERTS WITH SHEETMETAL SHIELDS CONTINUOUS THROUGH THE HANGER; UTILIZE CALCIUM SILICATE INSERTS OR STYRENE INSERTS. <br />2. UTILIZE RIGID INSERTS AND SHEETMETAL SHIELDS; INSULATION TO BE CONTINUOUS THROUGH THE HANGER; UTILIZE CALCIUM SILICATE INSERTS OR STYRENE INSERTS. <br />3. JACKETING: ALUMINUM ROLLED JACKETING (ARJ) APPLIED TO EXTERIOR PIPING INSULATION EXPOSED TO WEATHER (I.E. ROOFTOP PIPING). SEE INSULATION SPEC FORALTERNATE JACKETING AND LOCATIONS. <br />4. FOR PIPING SMALLER THAN 1 1121NCH AND LOCATED IN PARTITIONS WITHIN A CONDITIONED SPACE, MAY REDUCE THICKNESSES BY 1 INCH BUT TOTAL THICKNESS TO NOT BELOW r AS ALLOWED BY ENERGY CODE. <br />5. ASTM E 84 AND UL 723 TESTED AND LISTED TO FLAME SPREAD INDEX OF 25 AND SMOKE DEVELOPED INDEX OF NOT EXCEEDING 50. <br />ai0 try <br />fe Of Your Building <br />McKINSTRY Co, LLC <br />SEATTLE: <br />5005 3RD AVENUE S <br />PO BOX 24567 <br />SEATTLE, WA 98124 <br />1-800-669-6223 <br />www.mckinstrv.com <br />PROJECT. <br />MUKILTEO SD <br />PHASE 10 HVAC <br />IMPROVEMENTS <br />- HORIZON ES <br />222 W CASINO RD <br />EVERETT, WA 98204 <br />CONSULTANTS; <br />ISSUE: <br />PERMIT SET <br />05/06/2022 <br />REGISTRATION: <br />�R QIYF WA��'stb <br />s��Q� f�ca�e0 <br />52771 Q <br />Pol �E'OISTFIl <br />`rS10NAL <br />ISSUES <br />SR ENGINEER: <br />L. HESS <br />DRAWN BY: <br />M. SAFONOV N. HOBURG A. PASSAS <br />QC BY: <br />L. HESS <br />JOB NO: <br />205557-004 <br />ISSUED ON: <br />05106/2022 <br />SHEET TITLE: <br />MECHANICAL <br />SPECIFICATIONS <br />SHEET NUMBER: <br />M-003 <br />
The URL can be used to link to this page
Your browser does not support the video tag.