My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
222 W CASINO RD 2025-03-27
>
Address Records
>
W CASINO RD
>
222
>
222 W CASINO RD 2025-03-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2025 2:40:46 PM
Creation date
4/3/2023 8:04:28 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
222
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
952
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ABBREVIATIONS <br />AD <br />ACCESS DOOR <br />AFF <br />ABOVE FINISHED FLOOR <br />AFC <br />ABOVE FINISHED GRADE <br />BHP <br />BRAKE HORSEPOWER <br />BOP <br />BOTTOM OF PIPE <br />BOT <br />BOTTOM <br />C/L <br />CENTER LINE <br />CLG <br />CEILING <br />CFM <br />CUBIC FEET PER MINUTE <br />CO <br />CARBON MONOXIDE <br />CO2 <br />CARBON DIOXIDE <br />CSR <br />CURRENT SENSING RELAY <br />DISCH <br />DISCHARGE <br />DN <br />DOWN <br />DS <br />DISCONNECT SWITCH; DOOR SWITCH <br />(E) <br />EXISTING <br />EA <br />EACH <br />EC <br />ELECTRICAL CONTRACTOR; END CAP <br />EP <br />ELECTRICAL PANEL; END PLUG <br />EPO <br />EMERGENCY POWER OFF <br />ESP <br />EXTERNAL STATIC PRESSURE <br />(F) <br />FUTURE <br />FA <br />FIRE ALARM <br />FDC <br />FIRE DEPARTMENT CONNECTION <br />FEN <br />FOUNDATION <br />FLEX <br />FLEXIBLE <br />FLR <br />FLOOR <br />FP <br />FIRE PROTECTION <br />FTG <br />FOOTING <br />GA <br />GAGE <br />GALV <br />GALVANIZED <br />GC <br />GENERAL CONTRACTOR <br />HP <br />HORSEPOWER; HIGH PRESSURE <br />HTG <br />HEATING <br />HTR <br />HEATER <br />IAW <br />IN ACCORDANCE WITH <br />ID <br />IN SIDE DIAMETERIDIMENSION <br />IN WC <br />INCHES WATER COLUMN <br />MC <br />MECHANICAL CONTRACTOR <br />MFR <br />MANUFACTURER <br />MH <br />MANHOLE <br />MTD <br />MOUNTED <br />N/A <br />NOTAPPLICABLE <br />NC <br />NORMALLY CLOSED <br />NIC <br />NOT IN CONTRACT <br />NO <br />NORMALLY OPEN; NUMBER <br />NOM <br />NOMINAL <br />NTS <br />NOT TO SCALE <br />OC ON CENTER <br />OD OUTSIDE DIAMETER <br />OVHD OVERHEAD <br />PERF <br />PERFORATED <br />POC <br />POINT OF CONNECTION <br />QTY <br />QUANTITY <br />(R) <br />RELOCATED <br />RCP <br />REFLECTED CEILING PLAN <br />READ <br />REQUIRED <br />SECT SECTION <br />SIM SIMILAR <br />SPEC SPECIFICATION <br />STD STANDARD <br />TBD <br />TO BE DETERMINED <br />TI <br />TENANTIMPROVEMENTS <br />TOC <br />TOP OF CONCRETE <br />TOS <br />TOP OF STEEL <br />TSP <br />TOTAL STATIC PRESSURE <br />TYP <br />TYPICAL <br />UG <br />UNDERGROUND <br />UNO <br />UNLESS NOTED OTHERWISE <br />VFD <br />VARIABLE FREQUENCY DRIVE <br />VSD <br />VARIABLE SPEED DRIVE <br />W/ <br />WITH <br />W/o <br />WITHOUT <br />WC <br />WATER COLUMN <br />WG <br />WATER GAUGE <br />PIPING IDENTIFICATION <br />DUCTWORK ACCESSORIES VICINITY MAP <br />PROJECT SPECIFIC <br />HVAC <br />HVAC <br />AC <br />AIR CONDITIONING <br />RETURN PIPING <br />SUPPLY GRILLE <br />AHU <br />AIR HANDLING UNIT <br />SUPPLY PIPING <br />BED <br />BACKDRAFT DAMPER <br />BOD <br />BOTTOM OF DUCT <br />"" <br />RETURN OR EXHAUST GRILLE <br />PIPING FITTINGS <br />CC <br />COOLING COIL <br />CV <br />CONSTANTVOLUME <br />r <br />VOLUME DAMPER <br />TEE UP <br />DIFF <br />DIFFUSER <br />DAMPER <br />- <br />TEE DOWN <br />DOA <br />SUPPLY AIR -DOAS <br />TEE ON WI ELBOW <br />MOTOR OPERATED DAMPER <br />EA <br />EA <br />EXHAUST AIR GENERAL <br />- — <br />TEE UP WI ELBOW <br />EA2 <br />EXHAUST AIR -TYPE 2 <br />0 <br />90°ELBOW UP <br />H <br />EAT <br />ENTERING AIR TEMPERATURE <br />0 <br />90°ELBOW DN <br />ECG <br />EF <br />EGGCRATE GRILLE <br />EXHAUST FAN <br />] <br />CAP <br />AIRFLOW MONITOR <br />li <br />UNION <br />FCU <br />FAN COIL UNIT <br />FLANGE <br />FM <br />FD <br />FIRE DAMPER <br />FLEX HOSE CONNECTION <br />FE <br />AIR - <br />MPER <br />ATEDVOLUMEDAD) <br />FP <br />FIREEXHPROTECTUST <br />FIRE PROTECTION; FAN POWERED <br />ION: <br />LD <br />DOUBLE BELLOWS FLEX CONNECTION <br />(YOUNG REGULALY <br />(YOUNG REGULATOR OR APPROVED) <br />FSD <br />COMBINATION FIRE/SMOKE DAMPER <br />SINGLE BELLOWS FLEX CONNECTION <br />FTU <br />FAN TERMINAL UNIT <br />► <br />FLOW ARROW <br />GD <br />EXHAUST AIR -GREASE <br />REDUCER <br />GRD <br />GRILLE, REGISTER, DIFFUSER <br />1 % <br />SLOPE SYMBOL <br />BACK DRAFT DAMPER <br />- <br />_,I, <br />COORDINATE WITH CEILING APPURTENANCES, <br />HC <br />HEATING COIL <br />BREAK OR CONTINUATION SYMBOL <br />HVAC <br />HEATING, VENTILATION AND AIR CONDITIONING <br />DOWN SPOUT NOZZLE <br />I <br />CLEANOUT <br />FLEX CONNECTION <br />LAT <br />LEAVING AIR TEMPERATURE <br />ILE <br />LINEAR DIFFUSER <br />LPS <br />SUPPLY AIR -LOW PRESSURE <br />VALVES <br />FIRE DAMPER THROUGH WALL <br />MA <br />MIXEDAIR <br />MOTORIZED 2-WAY VALVE <br />MOD <br />MAU <br />MOTOR OPERATED DAMPER; MODULATING <br />MAKE-UP AIR UN IT <br />_ <br />MOTORIZED 3-WAY VALVE <br />FIRE DAMPER THROUGH FLOOR <br />MPS <br />SUPPLY AIR -MEDIUM PRESSURE <br />PRESSURE REDUCING VALVE <br />MUA <br />SUPPLY AIR - MAKE-UP AIR <br />CONTROL VALVE <br />FIRE/SMOKE DAMPER THROUGH WALL <br />OA <br />OUTSIDE AIR <br />S <br />OBD <br />OPPOSED BLADE DAMPER <br />RELIEF VALVE <br />I(S7 <br />BALL VALVE <br />5�, ¶ <br />FIREISMOKE DAMPER THROUGH FLOOR <br />PA <br />SUPPLY AIR - PRESSURIZATION <br />3-WAY GATE VALVE <br />v lu <br />BUTTERFLY VALVE <br />RA <br />RAT <br />RETURN AIR <br />RETURN AIR TEMPERATURE <br />DIAPHRAGM VALVE <br />® qp <br />ACCESSDOORS <br />RTU <br />ROOF TOP UNIT <br />CHECKVALVE <br />_ <br />NEEDLE VALVE <br />AD <br />SAT <br />SMOKE AIR TEMPERATURE <br />SD <br />SMOKE DAMPER; SMOKE DETECTOR <br />SMOKED <br />� <br />GLOBE VALVE <br />12x12 XSL <br />ACOUSTICALLY LINED DUCT (X` THICK <br />BE <br />EXHAUST AIR -SMOKE <br />GLOBE VALVE ANGLE <br />SOUND LINING) <br />SF <br />SUPPLY FAN <br />GLOBE VALVE 3-WAY <br />SL <br />SOUND LINED <br />C'4 <br />GATE VALVE <br />R <br />SLSM <br />SOUND LINED SHEET METAL <br />CHANGE OF ELEVATION RISE(R) DROP(D) <br />SM <br />SHEET METAL <br />PLUG VALVE <br />SO <br />SCREENED OPENING <br />BALANCING VALVE <br />SP <br />STATIC PRESSURE <br />HOSE BIBB <br />TURNING VANES <br />AUTO FLOW VALVE <br />TA <br />TG <br />TRANSFER AIR <br />TRANSFER GRILLE <br />RETURN/ EXHAUST I OUTSIDE AIR <br />TOD <br />VAV <br />TOP OF DUCT <br />VARIABLE AIR VOLUME <br />PIPING ACCESSORIES <br />SUPPLY I TRANSFER AIR <br />VD <br />VOLUME DAMPER <br />DUCTWORK <br />(D <br />PUMP <br />4MV <br />- <br />4AV <br />MANUAL AIR VENT <br />RECTANGULAR DUCT <br />AUTOMATIC AIR VENT <br />SUPPLY AIR DUCT <br />4HAV <br />TURNING UP OR TOWARD <br />PIPING <br />HIGH CAPACITY AIR VENT <br />RECTANGULAR DUCT <br />BD <br />STEAM BLOWDOWN <br />SHOCK ARRESTOR <br />�i <br />SUPPLY AIR DUCT <br />TURNING DOWN OR AWAY <br />BP <br />BACKFLOW PREVENTER <br />FS <br />FLOW SWITCH <br />RECTANGULAR <br />CA <br />COMPRESSED AIR <br />VB <br />RETURN AIR DUCT <br />CHICHILLED <br />WATER RETURN <br />VACUUM BREAKER <br />=T <br />TURNING UP OR TOWARD <br />CHI <br />CHILLED WATER SUPPLY <br />CNDS <br />CONDENSATE <br />PRESSURE GAUGE <br />RECTANGULAR DUCT <br />DRAIN <br />TANK OVERFLOW & DRAINS <br />i <br />RETURN AIR DUCT <br />TEMPERATURE SENSOR <br />TURNING DOWN OR AWAY <br />EWT <br />ENTERING WATER TEMPERATURE <br />4 <br />TEMPERATURE INDICATOR <br />RECTANGULAR DUCT <br />FCD <br />FLUE CONDENSATE DRAIN <br />pM <br />EXHAUSTAIRDUCT <br />FEED <br />BOILER FEED WATER <br />FLOW METER <br />TURNING UP OR TOWARD <br />FOF <br />FUEL OIL FILL <br />FOR <br />FUEL OIL RETURN <br />STRAINER WI BALL VALVE <br />RECTANGULAR DUCT <br />FOSY <br />OILLY <br />EXHAUST AIR DUCT <br />FOV <br />FUEL OIL VENTFUEL <br />— <br />— <br />PIPE SLEEVE <br />i <br />TURNING DOWN OR AWAY <br />G <br />NATURAL GAS <br />®� <br />STEAM TRAP <br />ROUND <br />2 G <br />5#G <br />NATURAL GAS -LOW PRESSURE, 2 PSI <br />NATURAL GAS- LOW PRESSURE, 5 PSI <br />T <br />SUPPLY AIR DUCT <br />FETES PLUG <br />TURNING UP OR TOWARD <br />HWR <br />HEATING WATER RETURN <br />SUCTION DIFFUSER W/ STRAINER <br />ROUND DUCT <br />HWS <br />HEATING WATER SUPPLY <br />REDUCED PRESSURE <br />ICx <br />SUPPLY AIR DUCT <br />LPC <br />LOW PRESSURE CONDENSATE <br />BACKFLOW PREVENTOR <br />Y <br />TURNING DOWN OR <br />LWT <br />LEAVING WATER TEMPERATURE <br />AWAY <br />ROUND DUCT <br />MpC <br />NDENSATE <br />DUCT <br />RETURN AUP <br />MPS <br />MEDIUM PRESSURE SIR <br />TEAM <br />INSTRUMENTATION AND CONTROLS <br />TURNNGOR TOWARD <br />RL <br />REFRIGERATION LIQUID <br />/ <br />ROUND DUCT <br />RS <br />REFRIGERATION SUCTION <br />i <br />RV <br />REFRIGERATION VENT <br />/ THERMOSTAT <br />I <br />RETURN AIR DUCT <br />TURNING DOWN OR <br />SCW <br />SOFTENED COLD WATER <br />o- SENSOR <br />ROUND DUCT <br />AWAY <br />SRV <br />STEAM RELIEF VENT <br />CO CARBON MONOXIDE SENSOR <br />EXHUAST AIR DUCT <br />TOP <br />TOP OF PIPE <br />CO CARBON DIOXIDE SENSOR <br />TURNING UP OR TOWARD <br />ROUND DUCT <br />OCC OCCUPANCY SENSOR <br />,c <br />IKy <br />EXHAUST AIR DUCT <br />SD SMOKE DETECTOR <br />TURNING DOWN OR <br />AWAY <br />GENERAL INFORMATION SYMBOLS <br />FLEXIBLE DUCT <br />NEW MECHANICAL WORK <br />FUTURE TI SCOPE & NEW WORK OTHER THAN MECHANICAL <br />POINT OF CONNECTION <br />POINT OF DEMOLITION <br />TL <br />CENTERLINE <br />KEY NOTE REFERENCE <br />PIPING RISER CALLOUT (CHW; HI <br />% <br />PIPING RISER # <br />PLAN NUMBER <br />% <br />SHEET NUMBER WHERE PLAN SHOWN <br />DETAIL OR DIAGRAM NUMBER <br />% <br />SHEET NUMBER <br />WHERE DETAILIDIAGRAM SHOWN <br />% <br />SECTION LETTER <br />% <br />SHEET NUMBER WHERE SECTION SHOWN <br />REVISION NUMBER -DENOTES NUMBER <br />AND DATE WHEN REVISION OR ISSUE <br />OCCURRED <br />REVISION CLOUD - DENOTES AREA OF <br />CHANGE <br />X <br />X DETAIL REFERENCE OUTLINE <br />WITH NUMBER AND SHEET LOCATION <br />GRILLE/REGISTER/DIFFUSER <br />PROJECT SPECIFIC <br />® <br />CEILING SUPPLY AIR DIFFUSER <br />CEILING RETURN GRILLE <br />OR TRANSFER AIR GRILLE <br />ZCEILING <br />EXHAUST GRILLE <br />0 <br />LOUVER PLAN VIEW <br />LOUVER (ELEVATION VIEW) <br />HVAC <br />— ANNOTATION <br />EQUIPMENT / LOUVER TAG <br />EF EQUIPMENT <br />2-1 DESIGNATION <br />CONSECUTIVE <br />FLOOR OF EQUIP. <br />LOCATION <br />GRILLE, REGISTER, OR DIFFUSER TAG <br />TYPE CODE ('EXIST' IF EXISTING) <br />SWG <br />x CFM <br />L CFM <br />PROJECT SITE <br />VV Casino Rd �� '•i <br />W Casino/,. ^ <br />«1no Rd <br />85th PI SW ; <br />a <br />f <br />222 W ; <br />Casino Rd <br />Horizon Elementary <br />School <br />3AveW <br />S <br />no Rd <br />A� <br />LEGAL DESCRIPTION <br />PARCEL NUMBER: 28041300102100 <br />SEC 13 TWP 28 RGE 04ALL TH PTN NW114 NE114 DAF BEG AT NE COR SD SUB TH S ALG E BDY SD <br />SUB 30FT M/L TO S BDY BEV PARK-MUK HWY (AS IT EXST PRIOR TO 1983) TH W ALG SD S BEY <br />664.2FT TO TPB TH S & PLW E LN SDSUB 1293.44FT TO S LN SO SUB TH W ALG SDS LN TO INT W LN <br />SO SUB TH N ALG W LN SDSUB TO S BEY BEV-PARK MUK HWY & TH E ALGSD S LN TPB LESS N 30FT <br />OF W 175FT TOSNO CO PER AF 509800 & LESS N 10FT OF E E 39FT TO CITY EV PER WD REC AF <br />BW3230200 & LESS PTN CONVYD TO CITY EV PER WD'S AFS 8301100292 & 8301310255 & 8301310256 & <br />8301100295 CDR BY VOL 1802PG 242 AF 8308080302 & LESS E 78FT OF N 243FT OF W 331.66FT THOF <br />MECHANICAL INDEX <br />SHEET NO <br />SHEET NAME <br />0 <br />a <br />0 <br />or <br />a <br />0 <br />M-001 <br />MECHANICAL LEGEND & ABBREVIATIONS <br />X <br />X <br />M-002 <br />MECHANICAL GENERAL NOTES, BOD,& RESPONSIBILITY MATRIX <br />X <br />X <br />M-003 <br />MECHANICAL SPECIFICATIONS <br />X <br />X <br />M-004 <br />MECHANICAL SPECIFICATIONS <br />X <br />X <br />M-020 <br />CONTROLS DIAGRAMS & SEQUENCE OF OPERATIONS <br />X <br />M-030 <br />MECHANICAL DIAGRAMS <br />- <br />X <br />M-M <br />MECHANICAL SCHEDULES <br />X <br />X <br />MD-101 <br />MECHANICAL DEMO PLAN - BUILDINGB <br />X <br />X <br />MD-102 <br />MECHANICAL DEMO PLAN - BUILDINGC <br />X <br />X <br />MD-103 <br />MECHANICAL DEMO PLAN -BUILDING D- LEVEL/ <br />X <br />X <br />MD-104 <br />MECHANICAL DEMO PLAN - BUILDINGS B&D- LEVEL 2 <br />X <br />X <br />M-101 <br />MECHANICAL PLAN-BUILDINGB <br />X <br />% <br />M-102 <br />MECHANICAL PLAN - BUILDINGC <br />% <br />% <br />M-103 <br />MECHANICAL PLAN -BUILDING D- LEVEL/ <br />X <br />X <br />M-104 <br />MECHANICAL PLAN - BUILDINGS B&D- LEVEL 2 <br />X <br />X <br />M-300 <br />MECHANICAL SECTIONS & ENLARGED PLANS <br />X <br />X <br />M500 <br />MECHANICAL DETAILS <br />X <br />CONTROLS ABBREVIATIONS <br />NOTE TO ENGINEER - THE ABBREVIATIONS AND SYMBOLS LIST IS BASED ON THE ANSVISA INDUSTRIAL CONTROLS STANDARD. <br />THESE SYMBOLS AND ABBREVIATIONS SHOULD BE USED WHEN GENERATING THE CONTROLS DIAGRAMS, SEQUENCE OF <br />EID <br />ENABLE I DISABLE <br />OPERATIONS, AND OTHER CONTROLS SCOPE. ALSO INDICATED ARE DEFINITIONS FOR THE ABBREVIATIONS AND SYMBOLS. <br />FCV <br />FLOW CONTROL VALVE <br />THESE DEFINITIONS ARE INTENDED AS A DESIGN AID, NOT TO INCLUDE IN THE DRAWING SET. <br />O/C <br />OPEN I CLOSE <br />0/0 <br />ON I OFF <br />DEFINITIONS <br />S/S <br />START I STOP <br />TCP <br />TEMPERATURE CONTROL PANEL <br />ANALOG- A MODULATING CONTROL SIGNAL. IE: 0-10 VOLTS, 4-20 MILLIAMPS) <br />TCV <br />TEMPERATURE CONTROL VALVE <br />MOD <br />MOTOR OPERATED DAMPER <br />BUILDING AUTOMATION SYSTEM -A CONTROL SYSTEM CONSISTING OF HARDWARE AND SOFTWARE TO CONTROL BUILDING <br />HVAC SYSTEMS <br />SYMBOLS <br />DIGITAL - A BINARY CONTROL SIGNAL <br />axp <br />OTB <br />THERMOSTAT <br />ENABLE/DISABLE- A BINARY SIGNAL TO GIVE PERMISSION FOR A SYSTEM TO OPERATE(IE BOILER ENABLE/DISABLE). <br />Oeoxa <br />T 1� <br />120 VTHERMOSTAT <br />FLOW CONTROL VALVE-AHYDRONIC VALVE THAT MODULATES FLOW BASED ONACONTROL SIGNAL <br />FIT <br />FLOW INDICATING TRANSMITTER <br />OPENICLOSE- ATWO POSITION DEVICE THAT IS EITHER 100% OPEN OR 100% CLOSED (IE TWO POSITION DAMPER) <br />FS <br />FLOW SWITCH <br />ONIOFF- A BINARY SIGNAL THAT ACTIVATES OR DEACTIVATES A DEVICE. <br />FT <br />FLOW TRANSMITTER <br />STARTISTOP - A BINARY SIGNAL THAT STARTS OR STOPS A PIECE OF EQUIPMENT. (IE EXHAUST FAN) <br />IS <br />CURRENT SWITCH <br />TEMPERATURE CONTROL PANEL- A PANEL THAT CONTAINS CONTROLLERS TO CONTROL HVAC SYSTEMS. <br />IT <br />CURRENT TRANSMITTER <br />TEMPERATURE CONTROL VALVE- A HYDRONIC VALVE THAT MODULATES TO CONTROL TO A DESIRED TEMPERATURE <br />SETPOINT <br />CO2 <br />CARBON DIOXIDE SENSOR <br />MOTOR OPERATED DAMPER - AN AIR DAMPER THAT MODULATES BASED ON A CONTROL SIGNAL. <br />PDT <br />PRESSURE DIFFERENTIAL TRANSMITTER <br />THERMOSTAT- A BAS SPACE MOUNTED TEMPERATURE SENSING DEVICE. DEVICE COULD INCLUDE DISPLAY, OCCUPANCY <br />DS <br />DUCT SMOKE DETECTOR <br />OVERRIDE, OR MANUAL TEMPERATURE ADJUSTMENT OPTIONS. <br />EPO <br />EMERGENCY POWER OFF <br />120V THERMOSTAT- A LINE VOLTAGE THERMOSTAT THAT CONTROLS ASSOCIATED HVAC EQUIPMENT, TYPICALLY LINE <br />VOLTAGE THERMOSTAT IS HARDWIRED DIRECTLY TO THE HVAC EQUIPMENT, NOT THROUGH THE BAS. <br />OS <br />OCCUPANCY SENSOR <br />PT <br />PRESSURE TRANSMITTER <br />FLOW TRANSMITTER - A MEASURING DEVICE SUCH AS AN AIRFLOW MEASURING STATION OR HYDRONIC FLOW METER. THE <br />DEVICE TRANSMITS AN ANALOG SIGNAL TO THE BAS. <br />PS <br />PRESSURE SWITCH <br />FLOW INDICATING TRANSMITTER- SAME AS A FLOW TRANSMITTER BUT THERE IS ALSO AN INDICATING DISPLAY AT THE <br />TE <br />TEMERATURE ELEMENT <br />DEVICE. <br />TS <br />TEMPERATURE SWITCH <br />FLOW SWITCH- A DEVICE THAT INDICATES FLOW AS A BINARY SIGNAL. TYPICALLY USED AS A FLOW PROOF. <br />RH <br />RELATIVE HUMIDTY SENSOR <br />CURRENT SWITCH - A DEVICE THAT GENERATES A BINARY SIGNAL WHEN CURRENT IS SENSED. TYPICALLY USED FOR <br />EQUIPMENT STATUS. <br />ZS <br />POSITION SWITCH <br />CARBON DIOXIDE SENSOR -A SENSOR THAT MEASURES CARBON DIOXIDE PARTS PER MILLION LEVELS AND TRANSMITS AN <br />ANALOG SIGNAL TO THE BAS. <br />AI <br />ANALOG INPUT <br />DIFFERENTIAL PRESSURE TRANSMITTER- A DEVICE THAT MEASURES THE DIFFERENCE IN PRESSURE BETWEEN TWO SENSING <br />qQ <br />ANALOG OUTPUT <br />POINTS AND SENDS AN ANALOG SIGNAL TO THE BAS. <br />DI <br />DIGITAL INPUT <br />DUCT SMOKE DETECTOR - A DEVICE WHICH DETECTS SMOKE IN A DUCT. TYPICALLY THE DEVICE IS 120V HARDWIRED SO <br />ACTIVATION OF THE SMOKE DETECTOR WILL AUTOMATICALLY SHUT OFF POWER TO THE ASSOCIATED HVAC SYSTEM. <br />DO <br />DIGITAL OUTPUT <br />EMERGENCY POWER OFF - A DEVICE THAT WILL SHUT OFF POWER TO ASSOCIATED SYSTEM. TYPICALLY 120V HARDWIRED <br />COM <br />COMMUNICATION WIRING <br />AND USED FOR BOILER SYSTEMS <br />'SEE PIPING AND DUCT SYMBOL LEGENDS FOR <br />HIGH PRESSURE SWITCH - A DEVICE THAT INDICATES PRESSURE AS A BINARY SIGNAL. TYPICALLY USED AS A 120V <br />ADDITIONAL <br />SYMBOL TYPES. <br />HARDWIRED SAFETY THAT WILL SHUT OFF POWER TO THE FAN IF THE PRESSURE IN THE SYSTEM IS TOO POSITIVE OR TOO <br />NEGATIVE. <br />RELATIVE HUMIDITY SENSOR - A SENSOR THAT MEASURES RELATIVE HUMIDITY LEVELS AND TRANSMITS AN ANALOG SIGNAL <br />TO THE BAS. <br />TEMPERATURE ELEMENT- A SENSOR THAT MEASURE TEMPERATURE AND TRANSMITS A SIGNAL TO THE BAS. THE USE OF <br />°TEMPERATURE ELEMENT' IS APPROPRIATE BECAUSE THE TRANSMITTED VALUE TO THE CONTROLLER IS DONE VIA A <br />RESISTIVE SIGNAL, NOT A 4-20 MA OR 0-10VDC. <br />TEMPERATURE SWITCH - A DEVICE THAT INDICATES TEMPERATURE AS A BINARY SIGNAL. TYPICALLY USED AS A 120V <br />HARDWIRED SAFETY THAT WILL SHUT OFF POWER TO THE FAN IF THE TEMPERATURE IN THE SYSTEM IS TOO LOW. (IE: <br />FREEZESTAT) <br />POSITION SWITCH -A DEVICE THAT SENSES POSITION AND TRANSMITS A BINARY SIGNAL TO THE BAS. IE: DAMPER END <br />SWITCH. <br />ANALOG INPUT - A MODULATING SIGNAL THAT COMES FROM THE FIELD DEVICE TO THE BAS SYSTEM. IE: THERMOSTAT. <br />ANALOG OUTPUT - A MODULATING SIGNAL SENT OUT FROM THE BAS TO THE FIELD DEVICE. IE: FLOW CONTROL VALVE. <br />DIGITAL INPUT -A BINARY SIGNAL THAT COMES FROM THE FIELD DEVICE TO THE BAS SYSTEM. IE: FLOW SWITCH: <br />DIGITAL OUTPUT - A BINARY SIGNAL SENT OUT FROM THE BAS TO THE FIELD DEVICE. IE: FAN STARTISTOP <br />COMMUNICATION WIRING- WIRING BETWEEN CONTROLLERS IN A RAS SYSTEM. ALLOWS NUMEROUS POINTS OF INFORMATION <br />TO COMMUNICATE THROUGH THE NETWORK CABLE. BAS NETWORK SPEED AND TRAFFIC CAN EFFECT CONTROLLABILITY. <br />BACNET MS/TP IS THE MOST COMMON COMMUNICATION WIRING, REQUIRING 22 GAUGE TWISTED PAIR WIRING BETWEEN THE <br />CONTROLLERS. SIGNET IP IS AN INTERNET BASED COMMUNICATION PROTOCOL THAT PLUGS INTO A NETWORK JACK <br />THROUGH A CAT 5e CABLE. <br />ai0 try <br />fe Of Your Building <br />WKINSTRY Co, LLC <br />SEATTLE: <br />5005 3RD AVENUE S <br />PO BOX 24567 <br />SEATTLE, WA 98124 <br />1-800-669-6223 <br />www.mckinstrv.com <br />PROJECT <br />MUKILTEO SD <br />PHASE 10 HVAC <br />IMPROVEMENTS <br />- HORIZON ES <br />222 W CASINO RD <br />EVERETT, WA 98204 <br />CONSULTANTS: <br />ISSUE: <br />PERMIT SET <br />05/06/2022 <br />REGISTRATION: <br />�R pF WA�Z'stb <br />f�ca�0, <br />52771 Q <br />PO.��,�E'GISTEIL�1�� <br />S10NAL <br />ISSUES <br />SR ENGINEER: L. HESS <br />DRAWN BY: M. SAFONOV N. HOBURG A. PASSAS <br />QC BY: L. HESS <br />JOB NO: 205557-004 <br />ISSUED ON: 05106/2022 <br />SHEET TITLE: <br />MECHANICAL LEGEND <br />& ABBREVIATIONS <br />SHEET NUMBER: <br />M-001 <br />
The URL can be used to link to this page
Your browser does not support the video tag.