SYSTEM SUMMARY STC DC/AC <br />(11.745 KW DC / 8.41 KW AC) <br />• 2X STRINGS OF 10 CONNECTED IN PARALLEL <br />• 1X STRING OF 9 CONNECTED IN PARALLEL <br />- (29) REC405AA PURE BLACK MODULES <br />- (29) ENPHASE IQ8PLUS-72-2-US MICROINVERTERS <br />STC DC: (29) 405 = 11.745 KW <br />STC AC: (29) 290 = 8.41 KW <br />AC wire details <br />Nominal <br />Backfeed '1.25 <br />Min <br />Total <br />Conductor <br />ccConductors <br />Expected <br />Adjusted ampacity (ampacity x temp <br />Conductor & <br />EGC size <br />Conductor <br />Max <br />V drop <br />Min EMT <br />Min PVC <br />Min RMC <br />WirelD <br />#Modules <br />Voltage <br />/cond. set <br />OCPD <br />Power <br />sets <br />/conduit <br />max temp <br />derate x conduit fill derate) <br />neutral size <br />(Cu) <br />metal <br />length <br />size <br />size <br />size <br />06 AWG BARE <br />MS-01 <br />10 <br />240 V <br />15.13 A <br />20 A <br />2.9 kW <br />1 <br />2 <br />29 <br />25 x 1.00 x - = 25.00 A <br />12 AWG (Q-Cable) <br />(NOT IN CONDUIT) <br />Cu <br />50 ft <br />0.86 % <br />06 AWG BARE <br />MS-02 <br />9 <br />240 V <br />13.61 A <br />15 A <br />2.6 kW <br />1 <br />2 <br />29 <br />25 x 1.00 x - = 25.00 A <br />12 AWG (Q-Cable) <br />(NOT IN CONDUIT) <br />Cu <br />50 ft <br />0.77 % <br />MCB-01 <br />10 <br />240 V <br />15.13 A <br />20 A <br />2.9 kW <br />1 <br />1 2 <br />1 29 <br />1 35 x 1.00 x 1.00 = 35.00 A <br />10 AWG THWN-2 <br />10 AWG THWN-2 <br />Cu <br />50 ft <br />0.52 % <br />1 0.50 in <br />0.50 in <br />0.50 in <br />MCB-02 <br />9 <br />240 V <br />13.61 A <br />15 A <br />2.6 kW <br />1 <br />2 <br />29 <br />35 x 1.00 x 1.00 = 35.00 A <br />10 AWG THWN-2 <br />10 AWG THWN-2 <br />Cu <br />50 ft <br />0.46 % <br />0.50 in <br />0.50 in <br />0.50 in <br />LC-01 <br />29 <br />240 V <br />43.86 A <br />50 A <br />8.4 kW <br />1 <br />2 <br />29 <br />50 x 1.00 x 1.00 = 50.00 A <br />08 AWG THWN-2 <br />10 AWG THWN-2 <br />Cu <br />10 ft <br />0.19 % <br />0.75 in <br />0.75 in <br />0.75 in <br />LC-02 <br />29 <br />240 V <br />43.86 A <br />60 A <br />8.4 kW <br />1 <br />2 <br />29 <br />65 x 1.00 x 1.00 = 65.00 A <br />06 AWG THWN-2 <br />10 AWG THWN-2 <br />Cu <br />10 ft <br />0.12 % <br />0.75 in <br />0.75 in <br />0.75 in <br />INTERCONNECTION 120% RULE <br />(MAIN PANEL) <br />INTERCONNECTION <br />120% RULE <br />NOT APPLICABLE <br />LINE -SIDE TAP DOES NOT AFFECT <br />MAIN PANEL <br />ELECTRICAL NOTES <br />1) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. <br />2) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. <br />3) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. <br />4) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. <br />5) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. <br />6) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. <br />7) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. <br />8) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. <br />9) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR ILSCO GBL-4DBT LAY -IN LUG. <br />10) PV EQUIPMENT SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NEC 690. <br />11) EXACT LOCATION OF AUXILIARY GROUNDING TO BE DETERMINED AT TIME OF INSTALL. <br />12) EXISTING WIRES MUST BE REPLACED IF SMALLER THAN LISTED MINIMUM SIZES PER NEC 310.15(B)(16). <br />EXTREME CASE MODULE OUTPUT <br />F'UKt is <br />Isc(25°C) = 10.14A, Tisc = 0.040%/°C <br />Isc(T) = Isc(25°C) x [1 + Tisc x (T-25°C)] <br />Isc(-7°C) = 10.01A, Isc(29°C) = 10.16A <br />Voc(25°C) = 48.90V, Tvoc =-0.240%/oC <br />Voc(T) = Voc(25°C) x [1 + Tvoc x (T-25°C)] <br />Voc(-7°C) = 52.66V, Voc(29°C) = 48.43V <br />SWITCH <br />ELECTRIC HchME C-NERGY <br />CONTRACTOR <br />NAME: SWITCH ELECTRIC HOME ENERGY <br />ADDRESS: 7226 139TH AVE NE LAKE <br />STEVENS, WA 98258 <br />PHONE: 4253125526 <br />CONTRACTOR LICENSE #: SWITCEL8340M <br />ELECTRICAL LICENSE #: SWITCEL91OPK <br />EMAIL: solar@myswitchelectric.com <br />REVISIONS - <br />DESCRIPTION I DATE I REV <br />SIGNATURE & SEAL <br />HOMEOWNER INFO <br />Q <br />W U) <br />D <br />Z <br />LL] O <br />>00 <br />Q O) <br />C/) <br />O <br />APN: 00409422901200 <br />EMAIL: - <br />PHONE: - <br />SHEET NAME <br />W <br />ry <br />LLJ <br />LLI <br />WIRING <br />CALCULATION <br />ANSI B <br />11" X 17" <br />SHEET NUMBER <br />PV-5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.