OWARNING I <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON LINE AND LOAD <br />SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />LABEL LOCATION: <br />INVERTER(S), AC DISCONNECT(S), AC <br />COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): NEC 2020: NEC 706.15 <br />(C)(4) & NEC 690.13(B) <br />LABEL LOCATION: <br />UTILITY SERVICE ENTRANCE/METER, INVERTER/DC <br />DISCONNECT IF REQUIRED BY LOCAL AHJ, OR <br />OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. <br />PER CODE(S): NEC 2020: 690.56(C)(2) <br />0 WARNING <br />POWER SOURCE OUTPUT CONNECTION <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />LABEL LOCATION: <br />ADJACENT TO PV BREAKER AND ESS OCPD (IF <br />APPLICABLE). <br />PER CODE(S): NEC 2020: NEC 705.12 (13)(3)(2) <br />WARNING DUAL POWER SOURCE <br />SECOND SOURCE IS PHOTOVOLTAIC SYSTEM <br />LABEL LOCATION: <br />POINT OF INTERCONNECTION <br />PRODUCTION METER <br />NEC 705.12(B)(3)(3) <br />LABEL LOCATION: <br />AC DISCONNECT/BREAKER/ <br />POINT OF CONNECTION <br />(PER CODE: NEC 690.13(B) <br />NOTES AND SPECIFICATIONS: <br />AWARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />DC VOLTAGE IS ALWAYS PRESENT <br />WHEN SOLAR MODULES ARE <br />EXPOSED TO SUNLIGHT <br />LABEL LOCATION: <br />DC DISCONNECT, POINT OF INTERCONNECTION <br />(PER CODE: NEC 690.13(B)) <br />� AWARNING I <br />THIS EQUIPMENT FED BY <br />MULTIPLE SOURCES: <br />JTAL RATING OF ALL OVERCURREN <br />DEVICES EXCLUDING MAIN POWER <br />SUPPLY SHALL NOT EXCEED <br />AMPACITY OF BUSBAR <br />LABEL LOCATION: <br />POINTS OF CONNECTION/BREAKER <br />CODE: NEC 705.12(B)(3)(3) <br />Erg 19■r•T•1•14rral04 <br />SERVICE PANEL IF SUM OF BREAKERS EXCEEDS PANEL <br />RATING <br />NEC 705.12 (13)(3)(2) <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF <br />INTERCONNECTION. <br />• SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE 2020 ARTICLE <br />110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR <br />IF REQUESTED BY THE LOCAL AHJ. <br />• SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE <br />WORDS, COLORS AND SYMBOLS. <br />• LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING <br />METHOD AND SHALL NOT BE HAND WRITTEN. <br />• LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT <br />INVOLVED. <br />• SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY <br />SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. <br />• DO NOT COVER EXISTING MANUFACTURER LABELS. <br />A CAUTION <br />PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED <br />LABEL LOCATION: <br />MSP (PER CODE: NEC 705.12(D) <br />& NEC 690.59 <br />LABEL LOCATION: <br />MAIN SERVICE DISCONNECT / UTILITY METER <br />(PER CODE: NEC 690.13(B)) <br />LABEL LOCATION: <br />EMT / CONDUIT RACEWAYS <br />(PER CODE: NEC690.31(D)(2) <br />4" <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN <br />PV SYSTEM AND REDUCE <br />SHOCK HAZARD IN THE <br />ARRAY. <br />LABEL LOCATION: <br />ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING <br />MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. <br />PER CODE(S): NEC 2020: IFC 690.56(C) <br />CAUTION: <br />MULTIPLE SOURCES OF POWER <br />POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE <br />FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN <br />AT: ® MAIN SERVICE PANEL & UTILITY METER <br />AC DISCONNECT, COMBINER BOX <br />COLEY AVENUE <br />PV ARRAY <br />(N) COMBINER BOX <br />(N) UNFUSED AC DISCONNECT <br />(E) MAIN SERVICE PANEL In I I <br />(E) UTILITY METER W <br />1207 COLBY AVE, EVERETT, WA 98201, USA <br />SWITCH <br />ELECTRIC HchME C-NERGY <br />CONTRACTOR <br />NAME: SWITCH ELECTRIC HOME ENERGY <br />ADDRESS: 7226 139TH AVE NE LAKE <br />STEVENS, WA 98258 <br />PHONE: 4253125526 <br />CONTRACTOR LICENSE #: SWITCEL8340M <br />ELECTRICAL LICENSE #: SWITCEL91OPK <br />EMAIL: solar@myswitchelectric.com <br />■ REVISIONS . <br />DESCRIPTION I DATE I REV <br />SIGNATURE 8r SEAL <br />HOMEOWNER INFO <br />�2 <br />V J <br />0 <br />Q <br />LL U) <br />D <br />Z <br />L L] 0 <br />>00 <br />Q 0) <br />ma <br />J <br />0 <br />ti LJJ <br />0 ry <br />N LLJ <br />> <br />Lu <br />