My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10330 EVERGREEN WAY GLINT CAR WASH 2023-04-10
>
Address Records
>
EVERGREEN WAY
>
10330
>
GLINT CAR WASH
>
10330 EVERGREEN WAY GLINT CAR WASH 2023-04-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2023 11:28:51 AM
Creation date
4/5/2023 3:40:38 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
10330
Tenant Name
GLINT CAR WASH
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Building Envelope Requirements List, pg 3 of 8 <br />2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by ©2021 NEEA, All rights reserved <br />The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State <br />Energy Code. Commercial Provisions. <br />For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />l I S <br />C402.2.1.2 Rooftop HVAC <br />Indicate rooftop HVAC equipment curb <br />A4-1 <br />equipment curbs <br />insulation R-value on roof section <br />YES <br />C103.2 Above/below grade <br />Indicate R-value(s) of cavity/continuous <br />A7-2 <br />C402.2.3 wall insulation <br />insulation on wall sections <br />C402.2.4 <br />YES <br />C303.2.1 <br />Indicate framing materials on wall sections <br />A7-2 <br />YES <br />Indicate method of framing for wood <br />A7-2 <br />construction per A 103.2 (std, int, adv) <br />NA <br />Indicate material density category, wall weight <br />and heat capacity for qualifying mass walls <br />NA <br />For qualifying ASTM C90 masonry walls, <br />indicate loose -fill core insulation material and <br />percentage of cores filled including grouted <br />cores, bond beams, vertical fills, headers and <br />any other grouted cores <br />NA <br />Indicate method of protection of exposed <br />exterior basement/crawlspace wall insulation <br />YES <br />C103.2 Opaque doors <br />Indicate rated U-factor or R-value (non- <br />2-1 <br />C402.4.4 <br />swinging) on wall sections or in door <br />schedules - applies to doors with less than <br />50% glazed area <br />NA <br />C402.4.4 Garage doors <br />Indicate rated U-factor for sectional and tilt - <br />up garage doors on wall sections or in door <br />schedules - applies to garage doors with less <br />than 14% glazed area; all other garage doors <br />shall comply as opaque doors <br />NA <br />C402.2.5 Floor over outdoor or <br />Indicate R-value(s) of cavity/continuous <br />unconditioned space <br />insulation on floor sections <br />insulation <br />NA <br />Indicate framing material on floor sections <br />Indicate material density category and weight <br />of qualifying mortis floor% <br />YES <br />C402.2.6 Slab -on -grade floor <br />Indicate R-value of continuous insulation on <br />A6-1, A6-2 <br />C303.2.1 insulation <br />wall section or foundation detail <br />YES <br />Indicate insulation extends down vertically <br />A6-1, A6-2 <br />and/or horizontally the required distance from <br />top of slab <br />NA <br />Indicate method of protection of exposed <br />exterior slab edge insulation <br />NA <br />Indicate R-value of continuous insulation on <br />wall section or foundation detail <br />NA <br />Indicate insulation extends down vertically <br />from top of slab and then horizontally under <br />the entire slab <br />NA <br />Indicate method of protection of exposed <br />exterior slab edge insulation <br />Page 318 <br />
The URL can be used to link to this page
Your browser does not support the video tag.