My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10330 EVERGREEN WAY GLINT CAR WASH 2023-04-10
>
Address Records
>
EVERGREEN WAY
>
10330
>
GLINT CAR WASH
>
10330 EVERGREEN WAY GLINT CAR WASH 2023-04-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2023 11:28:51 AM
Creation date
4/5/2023 3:40:38 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
10330
Tenant Name
GLINT CAR WASH
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by ©2021 NEEA, All rights reserved <br />The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State <br />Energy Code. Commercial Provisions. <br />For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />NA C402.2.8 <br />Radiant heating <br />Indicate insulation R-value behind radiant <br />system insulation <br />panels, U-bend/headers and bottom surface of <br />radiantly heated floors (other than heated slab - <br />on -grade) <br />YES C402.4.1 <br />Vertical fenestration <br />Provide total grass sf area of all above grade COMPLIANCE <br />C502.2.1 <br />maximum area <br />wall elements and rough opening sf area of all FORMS <br />vertical fenestration elements in the building, <br />for the prescriptive max allowed window -to - <br />wall ratio (WWR) calculation in the WSEC <br />envelope compliance reports; demonstrate <br />compliance for each space conditioning <br />category separately <br />C402.4.1.1 <br />Increased prescriptive <br />Provide calculations showing that not less that <br />C405.2.4.1 <br />maximum vertical <br />50% of the total conditioned floor area is <br />C502.2.1 <br />fenestration area with <br />within a daylight zone; demonstrate <br />daylight zones and <br />compliance for each space conditioning <br />controls <br />category separately <br />NA <br />Indicate in envelope plans that all lighting <br />fixtures located within daylight zones shall he <br />provided with daylight responsive controls per <br />Section C405.2.4.1 <br />NA <br />Indicate that the VT of vertical fenestration is <br />at least 1.1 times the rated SHGC or no less <br />than VT-0.55. whichever is greater <br />NA C402.4.1.3 <br />Increased prescriptiNe <br />Indicate high performance U-factors and <br />C502.2.1 <br />maximum vertical <br />SHGC values in fenestration schedules <br />fenestration area with <br />NA <br />high-performance <br />Indicate if an area -weighted U-factor is used <br />glazing <br />for multiple fenestration elements within the <br />same fenestration category per Table C402.4; <br />provide area -weighted U-factor calculation <br />C402.1.5 <br />Wall/vertical <br />Indicate if component performance with <br />fenestration target <br />target area adjustment will he used to account <br />area adjustment <br />for vertical fenestration area in excess of the <br />prescriptive maximum allowed; include target <br />area adjustment in WSEC envelope <br />compliance reports <br />NA C402.4.1 <br />Skylight maximum <br />Provide total gross sf area of roof. and rough <br />C502.2. 2 <br />area <br />opening sf area of all skylight elements in the <br />building, for the prescriptive max allowed <br />skylight -to -roof ratio (SRR) calculation in the <br />WSEC envelope compliance reports; <br />demonstrate compliance for each space <br />conditioning category separately <br />NA ('402.1.5.2 <br />Roof/skylight target <br />Indicate if component performance with <br />area adjustment <br />target area adjustment will be- used to account <br />for skylight area in excess of the prescriptive <br />maximum allowed; include target area <br />adjustment in WSEC envelope compliance <br />reports <br />YES C402.4 <br />U-factors, SHGC and <br />Indicate U-factors, SHGC and VT values in A2-1 <br />C402.4.3.4 <br />VT for all <br />fenestration schedules <br />C303.1.3 <br />fenestration <br />assemblies <br />Page 418 <br />
The URL can be used to link to this page
Your browser does not support the video tag.