My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10330 EVERGREEN WAY GLINT CAR WASH 2023-04-10
>
Address Records
>
EVERGREEN WAY
>
10330
>
GLINT CAR WASH
>
10330 EVERGREEN WAY GLINT CAR WASH 2023-04-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2023 11:28:51 AM
Creation date
4/5/2023 3:40:38 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
10330
Tenant Name
GLINT CAR WASH
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State <br />Energy Code, Commercial Provisions. <br />For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />NA Indicate exception and criteria utilized for all <br />building entrances and exit -only doors that do <br />not have a vestibule or air curtain <br />NA Indicate required performance for air curtains <br />installed per Exception 7 <br />NA For unconditioned vestibules, indicate which <br />envelope assembly (interior or exterior) <br />complies with the requirements for a <br />conditioned space <br />YES C103.2 Building enclosure air Indicate in project documents that building AO-1 <br />C402.5.1.2C leakage test enclosure air leakage testing is required for <br />402.5.1.2.1 WSEC compliance <br />R402.4.1.2 <br />NA Provide area calculations that account for all <br />six sides of the air barrier boundaries <br />YES For commercial buildings, indicate that AO-1 <br />building enclosure air leakage testing shall be <br />performed per ASTM C779 (or equivalent <br />method approved by the code official) and the <br />target leakage rate is 0.25 cfm/ft2 (1.5 <br />Us*m2) at 0.3 in. wg (75 Pa) <br />NA If the building is mixed residential / <br />commercial and three stories or less above <br />grade plane, indicate which building enclosure <br />air leakage test procedure will be used for the <br />Group R-2 / R-3 areas (Section 11402.4.1.2 or <br />C402.5.1.2); if per R402.4.1.2, indicate that <br />the target leakage rate is 5 air changes per <br />hour at 0.2 in. wg (50 Pa) <br />YES Include the following requirements in project AO-1 <br />documents: (1) Submit building enclosure air <br />leakage test reports to jurisdiction and owner; <br />(2) If initial test result exceeds 0.25 cfm/ft2 <br />(1.5 Us*m2), indicate that inspection and all <br />practical corrective actions be completed and <br />documented in the air leakage test report; (3) <br />If initial test result exceeds 0.40 cfm/ft2 (2.0 <br />Us*m2), indicate that corrective actions shall <br />also include re -testing; (4) Indicate that <br />corrective measures and retesting must be <br />repeated until the test result is 0.40 cfm/ft2 <br />(2.0 Us*m2) or less; (4) Include air barrier <br />test report in project close out documentation <br />provided to building owner. <br />ADDITIONAL EFFICIENCY CREDITS - REDUCED AIR INFILTRATION <br />NA C406.9 Reduced air To comply with additional efficiency credit, <br />infiltration indicate in project documents that the <br />building enclosure air leakage test results shall <br />not exceed 0.17 cfm/ft2 at 0.3 in. wg (75 Pa); <br />all documentation requirements per C 103.2 <br />and C402.5.1.2 apply <br />ALTERATIONS <br />Page 718 <br />
The URL can be used to link to this page
Your browser does not support the video tag.