My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10330 EVERGREEN WAY GLINT CAR WASH 2023-04-10
>
Address Records
>
EVERGREEN WAY
>
10330
>
GLINT CAR WASH
>
10330 EVERGREEN WAY GLINT CAR WASH 2023-04-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2023 11:28:51 AM
Creation date
4/5/2023 3:40:38 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
10330
Tenant Name
GLINT CAR WASH
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a I <br />2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 — Administered by 02021 NEEA, All rights reserved <br />The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State <br />Energy Code, Commercial Provisions. <br />For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />AIR LEAKAGE <br />NA C402.5.1.1 <br />Air barrier <br />Identify location and provide diagram of <br />construction and <br />continuous air barrier in plans and sections <br />sealing <br />YES <br />Provide details for all joints, transitions in A4-1, A7-1, A7-2 <br />materials, penetrations in air barrier and note <br />method of sealing (caulked, gasketed, or other <br />approved method) <br />NA C402.5.3 <br />Rooms containing <br />For room(s) located within the conditioned <br />C402.1.3 <br />fuel burning space <br />space that contain non -direct vent fuel- <br />C402.1.4 <br />conditioning <br />burning appliances that require outdoor air for <br />appliances <br />combustion, indicate method of isolation from <br />the conditioned space; include sealing of <br />walls, floor and ceiling of room, doorway <br />gasketting and sealing around ductwork and <br />piping penetrations <br />NA <br />Indicate walls, floor and ceiling of the room <br />envelope are insulated to the same level <br />required for exterior envelope, and <br />combustion air ductwork that passes thru <br />conditioned space is insulated to at least R-8 <br />NA C402.5.4 <br />Doors and access <br />Indicate locations of all doors and access <br />openings to shafts, <br />openings to shafts, chutes, stairways and <br />chutes, stairways and <br />elevator lobbies <br />elevator lobbies <br />NA <br />Indicate method of sealing of these openings <br />(gasketing, weatherstripping, other sealing <br />method); or exception taken <br />NA C402.5.5 <br />Outdoor air intakes, <br />Indicate locations of all stairway enclosure, <br />C403.7.8 <br />exhausts and relief <br />elevator shaft and building pressurization <br />openings <br />relief openings, outside air intakes and <br />exhaust openings <br />NA <br />Note in envelope plans that all relief, outside <br />air intake and exhaust openings shall be <br />provided with dampers in accordance with <br />Mechanical Section C403.7.8 <br />NA C402.5.8 <br />Recessed lighting in <br />Indicate method of sealing between light <br />building envelope <br />fixture housing and wall or ceiling <br />NA <br />Note in envelope plans that all recessed <br />lighting fixtures shall be IC rated and have an <br />air leakage rating not greater than 2 cfm per <br />ASTM E283 test; include these requirements <br />in lighting fixture schedules <br />NA C402.5.6 <br />Loading dock seals <br />Indicate weather seal at cargo and loading <br />dock doors <br />NA C402.5.7 <br />Vestibules <br />Indicate locations and dimensions of <br />vestibules for building entrances; also indicate <br />vestibule information for exit -only doors in <br />buildings where separate doors for entering <br />and exiting are provided <br />NA <br />Indicate locations of all building entrances and <br />exit -only doors provided with an air curtain in <br />lieu of a vestibule <br />Page 618 <br />
The URL can be used to link to this page
Your browser does not support the video tag.