My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3632 RUCKER AVE THE LANDING AT PORT GARDNER 2023-04-06
>
Address Records
>
RUCKER AVE
>
3632
>
THE LANDING AT PORT GARDNER
>
3632 RUCKER AVE THE LANDING AT PORT GARDNER 2023-04-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2023 3:14:26 PM
Creation date
4/6/2023 3:10:05 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3632
Tenant Name
THE LANDING AT PORT GARDNER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
225
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSIGHT ENGINEERING CO. <br /> i <br /> November 26, 2018 <br /> Paul McKee, Engineering/Permit Services <br /> 3200 Cedar Street <br /> Everett, WA 98201 <br /> (425)257-8810 <br /> Re: The Landing at Port Gardner—Permit#: PW 1805-050 <br /> IECO No. 17-0891 <br /> Dear Paul, <br /> The project referenced above is revised in response to the review comments dated November 21, <br /> 2018. The review comments are numbered on the letter and have been addressed in italics as <br /> follows: <br /> 1. Please see the list of comments below&revise plans accordingly prior to resubmitting to <br /> the Permit Services Counter. Please note that these comments are compiled from Public <br /> Works reviewers for the Public Works (civil)plans only. The applicant team may receive <br /> separate comment letters from the Building Department and/or the Planning Department <br /> for architectural or other types of drawings. <br /> DRAINAGE REPORT(Stormwater Plans): <br /> 1. Stormwater detention system must be watertight and able to pass leak down test during <br /> inspection. Replacement of detention system with one that meets City standards will be <br /> required if system fails to pass leak testing. <br /> The proposed stormwater detention system has a PVC liner within the system and should <br /> pass a leak test. <br /> 2. Provide Ecology approved pretreatment device upstream of detention system to prevent <br /> sediment buildup—show and call out on plans. <br /> We are proposing an Aquaswirl pretreatment system for the roof drains. The detail of the <br /> system is provided on sheet C4.4 <br /> PO Box 1478 • Everett, WA 98206 • Phone: (425)303-9363 <br /> Fax: (425)303-9362 • Email:info@insightengineering.net <br />