My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3632 RUCKER AVE THE LANDING AT PORT GARDNER 2023-04-06
>
Address Records
>
RUCKER AVE
>
3632
>
THE LANDING AT PORT GARDNER
>
3632 RUCKER AVE THE LANDING AT PORT GARDNER 2023-04-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2023 3:14:26 PM
Creation date
4/6/2023 3:10:05 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3632
Tenant Name
THE LANDING AT PORT GARDNER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
225
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Envelope Requirements Summary, pq 1 ENV-REQ <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Oct 2017 <br /> Minimum Requirements This table summarizes prescriptive compliance requirements for opaque elements and fenestration.Refer <br /> for Prescriptive Compliance to Tables C402.1.3,C402.1.4 and C402.4 in the 2015 WSEC for important footnotes that apply to <br /> these tables. Refer to Section C402 for all applicable requirements for each envelope element type and <br /> applicable exceptions. Refer to Section C410 for all applicable information for refrigerated spaces. <br /> Table C402.1.3 Notes 1,7 Table C402.1.4 Notes 1,2 <br /> Prescriptive Path Insulation Minimum R-Value Assembly Maximum U-factor <br /> Occupancy Group All Other Group R _ All Other Group R <br /> Opaque Elements <br /> Roofs <br /> Insulation Entirely above Deck 12738 c.i. R-38 c.i. U-0.027 U-0.027 <br /> Metal Building(with thermal spacer block)Note 3 R-25+R-11 Ls R-25+R-11 Ls U-0.031 U-0.031 <br /> Attic and Other R-49 R-49 U-0.021 U-0.021 <br /> Joist or single rafter R-49 R-49 U-0.027 U-0.027 <br /> Walls,Above-grade <br /> Mass R-9.5 c.i.Note 6 R-13.3 c.i. U-0.104 Note 6 U-0.078 <br /> Mass transfer deck slab edge No R-Value for prescriptive compliance U-0.200 U-0.200 <br /> Metal Building R-19 c.i. R-19 c.i. U-0.052 U-0.052 <br /> Steel Framed R-13+R-10c.i. R-19+R-8.5 c.i. U-0.055 U-0.055 <br /> Wood Framed and Other R-21 w/int.frame R-21 w/int.frame U-0.054 U-0.054 <br /> Below Grade Wall Note 4 Same as above grade Same as above grade <br /> Floors <br /> Mass R-30 c.i. R-30 c.i. U-0.031 U-0.031 <br /> Steel Joist R-38+R-10 c.i. R-38+R-10 c.i. U-0.029 U-0.029 <br /> Wood Framed and Other R-30 R-30 U-0.029 _ U-0.029 <br /> Slab-On-Grade Floors <br /> Unheated R-10 for 24 in.(from top of slab) F-0.54 F-0.54 <br /> Heated Note 5 R-10 perimeter&under entire slab F-0.55 F-0.55 <br /> Opaque Doors <br /> Swinging No R-Value for prescriptive compliance U-0.37 U-0.37 <br /> Nonswinging(Roll-up or sliding) R-4.75 R-4.75 U-0.34 _ U-0.34 <br /> Table C402.4-0-30%of wall area,or <br /> 30%-40%per Section C402.4.1.l DLZ Section C402.4.1.3 High Performance <br /> or Section C402.4.1.4 DOHS Fenestration Option-0-40%of wall area <br /> Fenestration Assembly Maximum U-factor Notes 1,2 <br /> Vertical Fenestration <br /> Nonmetal framing U-0.30 U-0.30 U-0.28 U-0.28 <br /> Metal framing(fixed) U-0.38 U-0.38 U-0.34 U-0.34 <br /> Metal framing(operable) U-0.40 U-0.40 U-0.36 U-0.36 <br /> Entrance doors U-0.60 U-0.60 U-0.60 U-0.60 <br /> Skylights <br /> Skylights U-(1.50 U-0.50 U-0.50 U-0.50 <br /> Fenestration Assembly Maximum SHGC Factor <br /> Vertical Fenestration PF<0.2:north-SHGC=0.53; PF<0.2:north-SHGC=0.46; <br /> all other SHGC=0.4 all other SHGC=0.35 <br /> 0.2_<PF<0.5:north-SHGC-0.58; 0.2<_PF<0.5:north-SHGC-0.51; <br /> all other-SHGC-0.48 all other-SHGC-0.42 <br /> PF i'0.5:all orientations-SHGC-0.64 PF z 0.5:all orientations-SHGC-0.56 <br /> Skylights SHGC-0.35 SHGC-0.35 <br /> C410.2 Refrigerated Spaces Insulation Insulation Minimum R-Value Assembly Maximum U-factor <br /> Freezers-Walk-in and Warehouse <br /> Roof/Ceiling R-32 U-0.030 <br /> Wall R-32 U-0.030 <br /> Door R-32 U-0.030 <br /> • <br /> Door-transparent reach-in triple-pane,heat-reflective treated or gas <br /> Floor R-28 U-0.035 <br /> Coolers-Walk-in and Warehouse <br /> Roof/Ceiling R-25 U-0.039 <br /> Wall R-25 U-0.039 <br /> Door R-25 U-0.039 <br /> Door-transparent reach-in double-pane,heat-reflective treated& <br /> gas fill,or comply with freezer door req. <br /> Floor No Requirement <br />
The URL can be used to link to this page
Your browser does not support the video tag.