My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3632 RUCKER AVE THE LANDING AT PORT GARDNER 2023-04-06
>
Address Records
>
RUCKER AVE
>
3632
>
THE LANDING AT PORT GARDNER
>
3632 RUCKER AVE THE LANDING AT PORT GARDNER 2023-04-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2023 3:14:26 PM
Creation date
4/6/2023 3:10:05 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3632
Tenant Name
THE LANDING AT PORT GARDNER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
225
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Note 1-If vertical fenestration or skylight area exceeds maximum allowed per C402.4.1,then Target Area Adjustment of all applicable envelope <br /> elements will be calculated automatically by the compliance form. Refer to Target Area Adjustments worksheet for this calculation. <br /> Note 2-Opaque assembly U-factors shall come from Appendix A or be calculated per approved method as specified in C402.1.5.1. <br /> Note 3-Proposed CMU mass wall in non-Group R that meet Table C402.1.4 Footnote D requirements can enter the target U-value of 0.104. <br /> Note 4-Semi-heated spaces-For spaces eligible for this wall insulation exception,the UA calculation excludes all wall assemblies.However, wall area <br /> values are required to run the window-to-wall ratio calculation.Enter into form all wall types in the semi-heated space.Enter the sf area of each <br /> wall type and enter"1"for the U-factor. <br /> Note 5-Mass transfer slab edges must be covered with an assembly having an overall U-factor of 0.2. <br /> Note 6-Demising walls,doors,and vertical fenestration separating spaces with different degrees of space conditioning(unconditioned,semi-heated, <br /> fully conditioned)shall be included only on the ENV-UA form for the space with the greatest degree of space conditioning. <br /> Note 7-List Group R above grade mass walls here.List all other above grade walls, Commercial and Group R,in the Opaque Walls-Above Grade <br /> section. <br /> Note 8 -Slab-on-grade F-Factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br /> Note 9 -Opaque door U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1.A door is defined as <br /> opaque if less than 50%of the door area has glazing. <br /> Note 10-Fenestration assembly U-Factors shall be the manufacturer's NFRC product rating, which includes the glazing and frame,or shall be <br /> the default value per Section C303.1.3. <br /> Note 11-Refrigerated Coolers-Target U-factors for cooler roof,wall and door assemblies are per C410.Enter proposed information <br /> under the most similar assembly type. Target F-factors for slab-on-grade floors are per C402. Target U-factors for floors that separate a cooler <br /> from a non-cooler space(unconditioned and conditioned)are per C402. Target U-factors for vertical fenestration(not within cooler doors)are per <br /> C402.Enter only the opaque portion of refrigerated space doors. Windows within doors and reach-in display case doors shall comply with C410 <br /> prescriptive requirements. <br /> Note 12-Refrigerated Freezers-Target U-factors for freezer roof,wall and door assemblies are per C410.Enter proposed information under the most <br /> similar assembly type. Target U-factor for insulated freezer floors is per C410. Insulation is required under the entire freezer floor.Enter <br /> proposed information in the Freezer Floor section.If the freezer floor assembly rests on top of a standard floor,the vertical edge of the freezer <br /> floor shall be entered as a section of freezer wall.If freezer floor insulation is installed as integral to or applied underneath a slab-on-grade or <br /> exposed floor,this floor area shall be thermally broken from the surrounding floor.Enter proposed thermal break information in the Freezer Floor <br /> section and note it as In-Floor Thermal Break.Enter only the opaque portion of freezer doors. Windows within doors and reach-in display case <br /> doors shall comply with C410 prescriptive requirements. <br /> Note 13-Stand alone projects-Enter total existing-to-remain sf areas for net above grade walls(including opaque doors),net roof,vertical fenestration <br /> and skylights in section provided at top of ENV-UA form.Enter UA information for new envelope assemblies in Building Components section. <br /> Note 14-Addition+Existing,Alteration+Existing,Addition+Alteration+Existing projects-Enter sf areas and estimated U-factors for all existing-to- <br /> remain envelope assemblies in Building Components section.Identify these assemblies as EXISTING in U-factor Source&Table#column. <br /> Enter UA information for new addition and altered envelope assemblies in Building Components section.Existing and new information will <br /> autofill into the Vertical Fenestration and Skylight Area Calculation section of ENV-SUM as all NEW.Does not affect calculation results. <br /> /G3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.