My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3632 RUCKER AVE THE LANDING AT PORT GARDNER 2023-04-06
>
Address Records
>
RUCKER AVE
>
3632
>
THE LANDING AT PORT GARDNER
>
3632 RUCKER AVE THE LANDING AT PORT GARDNER 2023-04-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2023 3:14:26 PM
Creation date
4/6/2023 3:10:05 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3632
Tenant Name
THE LANDING AT PORT GARDNER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
225
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• SHGC Calculation ENV-SHGC <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Oct 2017 <br /> Project Title: Landing at Port Gardner Date 10/05/2018 <br /> Target Insulation Allowance: For Building Department Use <br /> Fully Conditioned Space-Commercial,Group R,Mixed Use <br /> Fenestration Area as%gross above-grade wall area 11.7% Max.Target: 30.0% <br /> Skylight Area as%gross roof area 0.0% Max.Target: 5.0% <br /> Vertical Fenestration Alternates: None Selected on ENV-SUM <br /> Notes:1-Proposed vertical fenestration and skylight areas entered in ENV-SHGC must match proposed <br /> fenestration areas in ENV-UA. <br /> 2-If Target Area Adjustment is required per ENV-UA,then target areas will be automatically <br /> adjusted in ENV-SHGC.Refer to Target Area Adjustments worksheet for this calculation. <br /> 3-Fenestration assembly SHGC shall be the manufacturer's NFRC product rating,or shall be the <br /> default value per Section C303.1.3. <br /> 4-Fenestration that separates conditioned space from a non-conditioned space shall be included in this worksheet. User Note <br /> Enter target SHGC values for this fenestration under proposed SHGC,so it is neutral to the calculation. <br /> Skylights Proposed SHGC Target SHGC <br /> Sch.ID Provide SHGC source and fenestration schedule ID SHGC x Area(A) =SHGC x f SHGC x Area(A)= SHGC x A <br /> 0.35 <br /> SHGC 0.35 <br /> Skylight Totals <br /> All Non-North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF <br /> Sch.ID Provide SHGC source and fenestration schedule ID PF SHGC x Area(A)=SHGC x A Category SHGC x Area(A)= SHGC x A <br /> A Sheet A0.6 0.40 838 335 PF<0.2 0.40 2861 1144.4 <br /> B Sheet A0.6 0.40 1215 486 0.25PF<0.5 0.48 <br /> D Sheet A0.6 0.40 216 86 PF z 0.5 0.64 <br /> E Sheet A0.6 0.40 48 19 ++If projection factor(PF)credits are <br /> G Sheet A0.6 0.40 144 58 applied to the proposed design, Target <br /> H Sheet A0.6 0.40 104 42 SHGC will sum fenestration area by PF <br /> J1 Sheet A0.6 0.40 84 34 category. <br /> J2 Sheet A0.6 0.40 61 24 <br /> J3 Sheet A0.6 0.40 35 14 <br /> J4 Sheet A0.6 0 0.40 54 22 <br /> J5 Sheet A0.6 0 0.40 39 16 <br /> J6 Sheet A0.6 0 0.40 23 9 <br /> +If PF credit is applied,then vertical fenestration Non-North Window Totals 2861.0 1144.4 2861.0 1144.4 <br /> must be entered in the correct table according to _ <br /> orientation. If credit is not applied then all vertical <br /> fenestration can be entered in either table. <br /> North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF <br /> Sch.ID Provide SHGC source and fenestration schedule ID PF SHGC x Area(A)=SHGC x A Category SHGC x Area(A)= SHGC x A <br /> B Sheet A0.6 0.53 68 36 PF<0.2 0.53 304 161.1 <br /> C Sheet A0.6 0.53 44 23 0.25PF<0.5 0.58 <br /> F Sheet A0.6 0.53 192 102 PF z 0.5 0.64 <br /> ++If projection factor(PF)credits are applied <br /> to the proposed design, Target SHGC will <br /> sum fenestration area by PF category. <br /> North Window Totals 304.0 161.1 304.0 161.1 <br /> TO COMPLY-The Proposed Total SHGC x A Area SHGC x A Area SHGC x A <br /> shall not exceed the Target Total SHGC x A. Total(Skylight+Window) 3165.0 1305.5 3165.0 1305.5 <br /> Component Performance Compliance (SHGC) SHGC COMPLIES <br /> (iv -/7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.