My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3632 RUCKER AVE THE LANDING AT PORT GARDNER 2023-04-06
>
Address Records
>
RUCKER AVE
>
3632
>
THE LANDING AT PORT GARDNER
>
3632 RUCKER AVE THE LANDING AT PORT GARDNER 2023-04-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2023 3:14:26 PM
Creation date
4/6/2023 3:10:05 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3632
Tenant Name
THE LANDING AT PORT GARDNER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
225
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Building Permit Plans Checklist, pg. 2 ENV-CHK <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Oct 2017 <br /> Project Title: Landing at Port Gardner Date 10/05/2018 <br /> Applicability Code Location in Building <br /> (yes,no,na) Section Component Compliance information required in permit documents Documents Department Notes <br /> C103.2 Indicate rated U-factor(swinging)or R-value(non-swinging-roll- <br /> Yes C402.4.4 Opaque doors up/sliding)on wall sections or in door schedules-applies to doors with A0.6 <br /> less than 50%glazed area <br /> Floor over outdoor or Indicate R-value(s)of cavity/continuous insulation on floor sections; <br /> Yes C402.2.5 unconditioned space Indicate framing material on floor sections; A0.6 <br /> insulation Indicate material density category and weight of qualifying mass floors <br /> Indicate R-value of continuous insulation on wall section or foundation <br /> detail; <br /> Yes C402.2.6 Slab-on-grade floor Indicate insulation extends down vertically and/or horizontally the required Detail 4 on sheet <br /> C303.2.1 insulation distance from top of slab; WP1'0 <br /> Indicate method of protection of exposed exterior slab edge insulation <br /> Indicate R-value of continuous insulation on wall section or foundation <br /> Radiantly heated detail; <br /> na C402.2.6 slab-on-grade floor Indicate insulation extends down vertically from top of slab and then <br /> C303.2.1 insulation horizontally under the entire slab; <br /> Indicate method of protection of exposed exterior slab edge insulation <br /> Radiant heating Indicate insulation R-value behind radiant panels,U-bend/headers and <br /> na C402.2.8 system insulation bottom surface of radiantly heated floors(other than radiantly heated slab- <br /> on-grade) <br /> C402.4.1 Vertical fenestration Provide calculation for total vertical fenestration area as a percentage of <br /> Yes C502.2.1 gross above grade wall area(WWR)for new construction,additions and ENV-SUM <br /> C503.3.2 maximum area alterations in ENV-SUM <br /> Provide calculations showing that the percentage of overall conditioned <br /> floor area within daylight zones is equal to or greater than 50%in 1 and 2 <br /> story buildings;OR <br /> Provide calculations showing that the percentage of overall net floor area <br /> Increased within daylight zones is equal to or greater than 25%in buildings 3 stories Refer to E2.0 <br /> C402.4.1.1 prescriptive or more;include the gross floor area and list of spaces omitted for the net series for <br /> Yes C405.2.4.1 maximum vertical floor area; <br /> C502.2.1 fenestration area daylight zones <br /> C503.3.2 with daylight zones Note in envelope plans that all lighting fixtures located within daylight and all required <br /> and controls zones shall be provided with daylight responsive controls per WSEC information <br /> Section C405.2.4.1;indicate method of control in lighting fixture schedules <br /> Indicate that the VT of vertical fenestration is at least 1.1 times the rated <br /> SHGC <br /> increasea Indicate high performance U-factors and SHGC values in fenestration <br /> C402.4.1.3 prescriptive schedules; <br /> na C502.2.1 maximum vertical <br /> fenestration area Indicate if an area-weighted U-factor is used for multiple fenestration <br /> C503.3.2 with high- elements within the same fenestration category per Table C402.3;provide <br /> nerfnrmance nla7ina U-factor calculations <br /> Increased <br /> prescriptive Indicate that for eligibility,all occupied,conditioned spaces will be served <br /> C402.4.1.4 maximum vertical by a dedicated outside air system(DOAS)that delivers ventilation air <br /> na C403.6 fenestration area without requiring operation of the heating/cooling system per Section <br /> with DOAS C403.6 <br /> mechanical systems <br /> Wall/vertical Indicate if component performance with target area adjustment will be <br /> na C402.1.5 fenestration target used to account for vertical fenestration area in excess of the prescriptive <br /> area adjustment maximum allowed <br /> C402.4.1 Skylight maximum Provide calculation for total skylight area as a percentage of gross roof <br /> na C502.2.2 area area(SRR)for new construction,additions and alterations in ENV-SUM <br /> C503.3.3 <br /> Roof/skylight target Indicate if component performance with target area adjustment will be <br /> na C402.1.5.2 area adjustment used to account for skylight area in excess of the prescriptive maximum <br /> allowed <br /> Indicate U-factors,SHGC and VT values in fenestration schedules; <br /> U-factors,SHGC Indicate if an area-weighted U-factor is used for multiple fenestration <br /> yes C402.4.3 and VT for all elements within the same fenestration category per Table C402.3;provide A0.6 <br /> C303.1.3 fenestration U-factor calculations <br /> assemblies Indicate if values are NFRC or default;if default then specify frame type, <br /> glazing layers,gap width,low-e coatings,gas-fill <br /> Permanent shading For windows with overhangs or permanent projection shading devices, <br /> na C402.4.3 provide projection factor calculations(Equation C4-6)and associated <br /> devices minimum SHGC for north and non-north orientations <br />
The URL can be used to link to this page
Your browser does not support the video tag.