Building Permit Plans Checklist, pg. 2 ENV-CHK <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Oct 2017 <br /> Project Title: Landing at Port Gardner Date 10/05/2018 <br /> Applicability Code Location in Building <br /> (yes,no,na) Section Component Compliance information required in permit documents Documents Department Notes <br /> C103.2 Indicate rated U-factor(swinging)or R-value(non-swinging-roll- <br /> Yes C402.4.4 Opaque doors up/sliding)on wall sections or in door schedules-applies to doors with A0.6 <br /> less than 50%glazed area <br /> Floor over outdoor or Indicate R-value(s)of cavity/continuous insulation on floor sections; <br /> Yes C402.2.5 unconditioned space Indicate framing material on floor sections; A0.6 <br /> insulation Indicate material density category and weight of qualifying mass floors <br /> Indicate R-value of continuous insulation on wall section or foundation <br /> detail; <br /> Yes C402.2.6 Slab-on-grade floor Indicate insulation extends down vertically and/or horizontally the required Detail 4 on sheet <br /> C303.2.1 insulation distance from top of slab; WP1'0 <br /> Indicate method of protection of exposed exterior slab edge insulation <br /> Indicate R-value of continuous insulation on wall section or foundation <br /> Radiantly heated detail; <br /> na C402.2.6 slab-on-grade floor Indicate insulation extends down vertically from top of slab and then <br /> C303.2.1 insulation horizontally under the entire slab; <br /> Indicate method of protection of exposed exterior slab edge insulation <br /> Radiant heating Indicate insulation R-value behind radiant panels,U-bend/headers and <br /> na C402.2.8 system insulation bottom surface of radiantly heated floors(other than radiantly heated slab- <br /> on-grade) <br /> C402.4.1 Vertical fenestration Provide calculation for total vertical fenestration area as a percentage of <br /> Yes C502.2.1 gross above grade wall area(WWR)for new construction,additions and ENV-SUM <br /> C503.3.2 maximum area alterations in ENV-SUM <br /> Provide calculations showing that the percentage of overall conditioned <br /> floor area within daylight zones is equal to or greater than 50%in 1 and 2 <br /> story buildings;OR <br /> Provide calculations showing that the percentage of overall net floor area <br /> Increased within daylight zones is equal to or greater than 25%in buildings 3 stories Refer to E2.0 <br /> C402.4.1.1 prescriptive or more;include the gross floor area and list of spaces omitted for the net series for <br /> Yes C405.2.4.1 maximum vertical floor area; <br /> C502.2.1 fenestration area daylight zones <br /> C503.3.2 with daylight zones Note in envelope plans that all lighting fixtures located within daylight and all required <br /> and controls zones shall be provided with daylight responsive controls per WSEC information <br /> Section C405.2.4.1;indicate method of control in lighting fixture schedules <br /> Indicate that the VT of vertical fenestration is at least 1.1 times the rated <br /> SHGC <br /> increasea Indicate high performance U-factors and SHGC values in fenestration <br /> C402.4.1.3 prescriptive schedules; <br /> na C502.2.1 maximum vertical <br /> fenestration area Indicate if an area-weighted U-factor is used for multiple fenestration <br /> C503.3.2 with high- elements within the same fenestration category per Table C402.3;provide <br /> nerfnrmance nla7ina U-factor calculations <br /> Increased <br /> prescriptive Indicate that for eligibility,all occupied,conditioned spaces will be served <br /> C402.4.1.4 maximum vertical by a dedicated outside air system(DOAS)that delivers ventilation air <br /> na C403.6 fenestration area without requiring operation of the heating/cooling system per Section <br /> with DOAS C403.6 <br /> mechanical systems <br /> Wall/vertical Indicate if component performance with target area adjustment will be <br /> na C402.1.5 fenestration target used to account for vertical fenestration area in excess of the prescriptive <br /> area adjustment maximum allowed <br /> C402.4.1 Skylight maximum Provide calculation for total skylight area as a percentage of gross roof <br /> na C502.2.2 area area(SRR)for new construction,additions and alterations in ENV-SUM <br /> C503.3.3 <br /> Roof/skylight target Indicate if component performance with target area adjustment will be <br /> na C402.1.5.2 area adjustment used to account for skylight area in excess of the prescriptive maximum <br /> allowed <br /> Indicate U-factors,SHGC and VT values in fenestration schedules; <br /> U-factors,SHGC Indicate if an area-weighted U-factor is used for multiple fenestration <br /> yes C402.4.3 and VT for all elements within the same fenestration category per Table C402.3;provide A0.6 <br /> C303.1.3 fenestration U-factor calculations <br /> assemblies Indicate if values are NFRC or default;if default then specify frame type, <br /> glazing layers,gap width,low-e coatings,gas-fill <br /> Permanent shading For windows with overhangs or permanent projection shading devices, <br /> na C402.4.3 provide projection factor calculations(Equation C4-6)and associated <br /> devices minimum SHGC for north and non-north orientations <br />