Laserfiche WebLink
• Building Permit Plans Checklist, pg. 3 ENV-CHK <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Oct 2017 <br /> Project Title: Landing at Port Gardner Date 10/05/2018 <br /> Applicability Code Location in Building <br /> (yes,no,na) Section Component Compliance information required in permit documents Documents Department Notes <br /> In single story buildings,provide list of enclosed areas that exceed 2,500 <br /> sf;for each space identify the space use,floor area,floor to ceiling height, <br /> whether skylights are installed,and any exception taken; <br /> Provide calculations for percentage of conditioned floor area located within <br /> Spaces in single a daylight zone including skylight and eligible sidelight daylight zones; <br /> na C402.4.2 story buildings <br /> requiring skylights Provide calculations for percentage of skylight area in each space over <br /> 2,500 sf,OR; <br /> Provide calculations for skylight effective aperture(Equation C4-5)for <br /> each space over 2,500 sf; <br /> Indicate haze factor of skylight glazing material or diffuser <br /> ADDITIONAL EFFICIENCY PACKAGE OPTION-ENHANCED ENVELOPE PERFORMANCE <br /> To comply with additional efficiency package option,demonstrate <br /> na C406.8 Enhanced envelope envelope insulation compliance via component performance;provide ENV- <br /> performance UA/ENV-SHGC compliance forms;verify that building total UA is 15% <br /> lower than the Code target UA <br /> AIR LEAKAGE <br /> Identify location and provide diagram of continuous air barrier in plans and <br /> Air barrier sections; <br /> Yes C402.5.1.1 construction and Provide details for all joints,transitions in materials,penetrations in air D1.1 <br /> sealing barrier and note method of sealing(caulked,gasketed,or other approved <br /> method) <br /> Rooms containing Indicate that rooms)containing non-direct vent appliances is isolated from <br /> open combustion conditioned space by the thermal envelope with a sealed air barrier, <br /> na C402.5.3 fuel burning including doorway gasketing and sealing around ductwork and piping <br /> appliances used for <br /> penetrations; <br /> space conditioning Indicate insulation provided in wall,floor and ceiling of the room envelope, <br /> and insulation required on combustion air ductwork <br /> Access openings Indicate locations of all access openings and doors to shafts,chutes, <br /> and doors to shafts, stairways and elevators; <br /> Yes C402.5.4 chutes,stairways A0.6,A3 series <br /> Y Indicate method of gasketing,weatherstripping and sealing of these <br /> and doors openings <br /> Indicate locations of all stairway enclosure,elevator shaft and building <br /> Outdoor air intakes, pressurization relief openings,outside air intakes and exhaust openings; To be provided in <br /> Yes C402.5.5 exhausts and relief <br /> C403.2.4.3 Note in envelope plans that all relief,outside air intake and exhaust the mechanical <br /> openings opens sa beprovided withdampers n acrnc wieaw <br /> Sectionni C403.2h .4.3 <br /> Indicateg methodll of sealing between light fixturec housinge and wall orchanic ceiling;l Referingselectrical <br /> to <br /> Yes C402.5.8 Recessed lighting in drawings and <br /> building envelope Note in envelope plans that all recessed lighting fixtures shall be IC rated electrical energy <br /> and have an air leakage rating not greater than 2 cfm per ASTM E283 test; code <br /> include these requirements in lighting fixture schedules <br /> na C402.5.6 Loading dock seals Indicate weather seal at cargo and loading dock doors <br /> na C402.5.7 Vestibules <br /> Indicate locations andprov dimensions of vestibulesi andda air curtains;M <br /> Indicate exception and criteria utilized da for all building o entrancesth and exits <br /> that do not have a vestibule or air curtain;e <br /> Indicate required performance for air curtains installed per exception 7; <br /> For unconditioned vestibules,indicate which envelope assembly(interior <br /> or exterior)complies with the requirements fora conditioned space _ <br /> Indicate on plans the location of air barrier boundaries and area <br /> calculations on all six sides of the air barrier; <br /> Indicate air barrier test method in accordance with ASTM E779 or <br /> approved equivalent; <br /> Indicate required maximum leakage rate for compliance. <br /> C103.2 Building air leakage <br /> na C402.5.1.2 test Include the following requirements in project documents:(1)Submit air <br /> barrier test report to jurisdiction once test is completed;(2)If test results <br /> exceed 0.40 cfm/ft2(1.5 Us*m2)at 0.3 in.wg(75 Pa),then visually inspect <br /> air barrier and seal noted sources of leakage;(3)Submit a follow-up report <br /> to jurisdiction noting corrective measures taken; (4)Include air barrier test <br /> report in compliance documentation provided to building owner. <br />