Laserfiche WebLink
Jee,n. PUBLIC WORKS <br /> MEMORANDUM <br /> TO: Paul McKee <br /> FROM: Richard Hefti <br /> 044-- <br /> DATE: July 26, 2018 <br /> RE: PW1805-050, 3632 Rucker Ave <br /> CC: Arnie Roshak <br /> A. General Plan Comments <br /> 1. North arrow is incorrect on all sheets. <br /> 2. C4 notes reference Mukilteo Water District, not City of Everett standards. <br /> 3. CB labeling in Detail 1/C4.1 incorrectly notes #3 while CB label on drainage plans note <br /> #1. <br /> 4. Storm Tank Details, Sheet C4.3 <br /> a. See annotated C4.3 attached. <br /> b. Obviously these details are from manufacturer and very generic. It would be <br /> helpful to revise so they are more representative of what is proposed to be built. <br /> B. Drainage Report Comments <br /> No exceptions taken. <br /> C. Recommendations <br /> 1. Perhaps add backflow valve on sewer service line. Don't think anybody wants sewage <br /> backing up into the StormTank. <br /> 2. Having not seen the building plans, I don't know if the garage floor will be constructed <br /> to allow for construction joints to line up with the StormTank footprint. If they do, it <br /> would be much easier to remove if the StormTank ever needs repair or replacement. <br /> S:\Document Location <br />