Laserfiche WebLink
• Building Permit Plans Checklist, pg. 4 ENV-CHK <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Oct 2017 <br /> Project Title: Landing at Port Gardner Date 10/05/2018 <br /> Applicability Code Location in Building <br /> (yes,no,na) Section Component Compliance information required in permit documents Documents Department Notes <br /> ADDITIONAL EFFICIENCY PACKAGE OPTION-REDUCED AIR INFILTRATION <br /> To comply with additional efficiency package option,indicate in project <br /> educed air documents that the air barrier test results shall not exceed 0.25 cfm/ft2 <br /> na C406.9 R <br /> infiltration (0.94 Us`m2)at 0.3 in.wg(75 Pa);indicate air barrier test report shall be <br /> submitted to the jurisdiction and building owner once test is completed <br /> ALTERATIONS <br /> For a roof alteration where existing ceiling cavities are exposed,indicate <br /> na cavities are insulated to full depth at R-3 per inch <br /> C503.1 Roof alteration- <br /> C503.3.1 insulation For a roof covering replacement where insulation is installed entirely <br /> na above the roof deck,indicate insulation complies with requirements for <br /> new construction per Tables C402.1.3 or C402.1.4 <br /> Wall and floor For a wall or floor alteration(floor over outdoor or unconditioned space) <br /> na C503.1 alteration insulation where existing envelope cavities are exposed,indicate cavities are <br /> insulated to full depth at R-3 per inch <br /> Where the addition of new vertical fenestration results in total building <br /> Addition of vertical window-to-wall ratio(WWR)exceeding the maximum allowed per <br /> na C503.3.2 fenestration C402.4.1,demonstrate method of compliance(vertical fenestration <br /> alternate per C503.3.2,or component performance compliance with target <br /> area adjustment for the total building) <br /> Where the addition of new skylights results in total building skylight-to-roof <br /> na C503.3.3 Addition of skylights ratio(SRR)exceeding the maximum allowed per C402.4.1,demonstrate <br /> component performance compliance with target area adjustment for the <br /> total building <br /> PROJECT CLOSE OUT DOCUMENTATION <br /> Project close out Indicate in plans that project close out documentation is required including <br /> na C103.6.3 documentation applicable WSEC envelope compliance forms and calculations,and <br /> requirements fenestration NFRC rating certificates <br /> If"no"is selected for any question, provide explanation: <br /> End of Building Permit Plans Checklist <br />