My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3632 RUCKER AVE THE LANDING AT PORT GARDNER 2023-04-06
>
Address Records
>
RUCKER AVE
>
3632
>
THE LANDING AT PORT GARDNER
>
3632 RUCKER AVE THE LANDING AT PORT GARDNER 2023-04-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2023 3:14:26 PM
Creation date
4/6/2023 3:10:05 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3632
Tenant Name
THE LANDING AT PORT GARDNER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
225
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1. The minimum sone rating of 1.0 should be shown for the whole house fans. IMC Section <br /> 403.8.6.5 <br /> 2. The requirements of WSEC C402.5.1.2 for testing of the air barrier should be shown on <br /> the plans. <br /> Structural <br /> 1. On Sheet S2.1 Grid 1/E and Sheet C4.1 in the Civil Drawing set, there is a "Flow Control <br /> Structure" with a rim elevation of 188.50 feet. The top of slab on this sheet is 181'-9". <br /> Please clarify if a site retaining wall is required at this location and if the opening shown <br /> in this area needs to revised or relocated based on the proposed rim elevation of the"Flow <br /> Control Structure". <br /> 2. It appears that the redundancy factor, p, of 1.0, per ASCE 7-10 12.3.4.2, was included in <br /> the design of the lateral systems in either the concrete or the wood portions of the <br /> structure. Please provide supporting calculations to verify that these lateral systems in <br /> both orthogonal directions meet the requirements of p = 1.0. Otherwise, please provide <br /> design calculations and revise the lateral design as required to satisfy the increase due to <br /> the redundancy factor, p =1.3. <br /> 3. Based on the use of the Equivalent Lateral Force procedure in ASCE 7-10 Sec 12.8. Please <br /> provide drift calculations to verify that the Torsional Amplification factor, Ax, does not <br /> need to be increased more than 1.0 per ASCE 7-10 12.8.4.3. <br /> 4. Please provide checks for structural irregularities for both structures concrete and wood <br /> portions per Tables 12.3-1 and 12.3-2 in ASCE 7-10. <br /> 5. Permit calculations for the concrete column design do not appear to include tie design <br /> check requirements per ACI 318-14 Sec 18.14.3. Please provide calculations and revise <br /> tie designs are required. <br /> 6. It appears that concrete dowel designs between PT slab to concrete shear wall elements <br /> are using a (p =0.75 rather than the (p-factor of 0.6 per ACI 318-14 Sec 21.2.4.2 as this <br /> would correspond to the 0.6 factor used in concrete shear wall designs calculations. <br /> Please revise dowel design as required. <br /> In order for the processing of your application to continue, it will be necessary to provide the <br /> Building Division with two new sets of revised construction documents reflecting the corrections <br /> requested. Please include a response letter which indicates how the corrections were resolved. <br /> All codes cited refer to the 2015 International Building Code (IBC), 2015 International Existing <br /> Building Code (IEBC), the 2015 International Fire Code (IFC), the 2015 International Mechanical <br /> Code (IMC), and/or the 2015 Washington State Energy Code (WSEC), as amended by the State <br /> 3002 Wetmore Ave. © 425.257.8800 O EPD@everettwa.gov <br /> Everett, WA 98201 425.257.8882 fax everettwa.gov <br />