My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3632 RUCKER AVE THE LANDING AT PORT GARDNER 2023-04-06
>
Address Records
>
RUCKER AVE
>
3632
>
THE LANDING AT PORT GARDNER
>
3632 RUCKER AVE THE LANDING AT PORT GARDNER 2023-04-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2023 3:14:26 PM
Creation date
4/6/2023 3:10:05 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3632
Tenant Name
THE LANDING AT PORT GARDNER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
225
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> Mr. Charlie Morgan,Jr. <br /> Charles Morgan &Associates <br /> Plan Check Number: B1805-043, Second Review <br /> October 24, 2018 <br /> c. The relative stiffness of the walls shall be considered per IBC Section 1604.4 and AWC <br /> SDPWS-15 Section 4.2.5.2. Documentation substantiating the wall stiffnesses shall be <br /> included in the calculation package. <br /> d. The seismic analysis shall evaluate the structure for torsional irregulaties per ASCE 7-10 <br /> Table 12.3-1 Items la and lb. <br /> e. The seismic analysis shall include accidental torsion including amplification per ASCE 7- <br /> 10 Sections 12.8.4.2 and 12.8.4.3. <br /> f. The wind analysis shall consider the load combinations of ASCE 7-10 Section 27.4.6 and <br /> Figure 27.4-8. All cases shall be considered unless documentation substantiates that <br /> structure satisfies the requirements of Section D1.2.1 at each level. See IBC Section <br /> 1609.1.1. <br /> 8. The wood structure has a Type 2"Reentrant Corner horizontal structural irregularity per <br /> ASCE 7-10 Table 12.3-1. Furthermore, it appears that the structure may require collectors <br /> to transfer loads to the wood shear walls. The design forces shall be increased by 25% for <br /> collectors and connections of collectors and diaphragms to the shear walls. Calculations <br /> substantiating the design of the elements for the increased loads shall be submitted for <br /> review. Collectors shall be shown on the plans where required and details provided as <br /> needed. See IBC Sections 1603.1, 1604.1, 1604.4, and 1613.1. <br /> 9. Documentation shall be submitted for review substantiating that the elevated slab on Sheet <br /> S2.2 satisfies the requirements of ACI 318-14 Section 18.14.5.1. Calculations for the design <br /> shears in the slab shall be included. The shears determined from moments induced in the <br /> column-slab joint shall be consistent with the column design per Comment 5. Alternatively, <br /> shears based on a conservative fix-joint assumption may be used. See IBC Section 1901.2. <br /> 10.The shear wall holdown design has not been provided in the structural calculations. The <br /> earthquake component of the holdown forces exceeds 20% of the total uplift. The <br /> earthquake component shall be increased per the provisions of ACI 318-14 Section <br /> 17.2.3.4.3. Calculations substantiating the holdown design should be submitted for review. <br /> The holdown design shall be performed using factored loads. See IBC Section 1901.2. <br /> 11.The project includes an elevator in the southwest corner of the building. The"Design <br /> Criteria and Loads"section of the Structural General Notes on Sheet SO.1 does not specify <br /> design criteria for the elevator system. The following comments should be addressed: <br /> a. The elevator design drawings should be included in the list of deferred submittals in the <br /> Structural General Notes. See IBC Section 107.3.4.1. <br /> b. The design loads for the elevator system, including impact loading, should be specified <br /> in the"Elevators"section of the Structural General Notes. At a minimum, estimated <br /> design loads should be specified for the design, and verified when the elevator design <br /> drawings are submitted for review. See IBC Sections 1603.1.8 and 1607.9.1. <br /> c. The building structure (i.e., elevator shaft and supporting floor framing) that supports <br /> components of the elevator system is included in the current submittal drawings. <br /> Calculations substantiating the design of the structure t upport the elevator loads <br /> © <br /> 3200 Cedar Street © 425.257.8800 O everettpw@everettwa.gov <br /> Everett,WA 98201 425.257.8882 fax everettwa.gov <br />
The URL can be used to link to this page
Your browser does not support the video tag.