My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3632 RUCKER AVE THE LANDING AT PORT GARDNER 2023-04-06
>
Address Records
>
RUCKER AVE
>
3632
>
THE LANDING AT PORT GARDNER
>
3632 RUCKER AVE THE LANDING AT PORT GARDNER 2023-04-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2023 3:14:26 PM
Creation date
4/6/2023 3:10:05 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3632
Tenant Name
THE LANDING AT PORT GARDNER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
225
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> Mr. Charlie Morgan, Jr. <br /> Charles Morgan &Associates <br /> Plan Check Number: B1805-043, Second Review <br /> October 24, 2018 <br /> concurrently with other loads should be submitted for review. The calculations should <br /> include the evaluation of deflection limits per IBC Section 1607.9.1. The design shall <br /> consider concurrent multi-directional loading as determined by the elevator <br /> manufacturer. See IBC Sections 1604.2 and 1605. <br /> d. The connections between the elevator guide rails and the structural framing are typically <br /> the responsibility of the engineer-of-record for the building system. At a minimum, <br /> connection details between the rail bracket and structural framing are required. <br /> Calculations and details for the elevator connections to the structural framing should be <br /> submitted for review. The design shall consider concurrent multi-directional loading as <br /> determined by the elevator manufacturer. The required locations and maximum spacing <br /> for the connection points should be specified in the structural drawings. See IBC <br /> Section 107.2.1 and 1604.4. <br /> e. The structural calculations shall be performing using the appropriate load combinations <br /> including live and seismic loading per IBC Section 1605.2 or 1605.3. In addition, <br /> documentation shall be submitted verifying the nominal loads have been increased for <br /> impact effects per IBC Section 1607.9.1. The application of the live load factors in the <br /> LRFD load combinations does not satisfy this requirement. <br /> f. The elevator shaft at Grid F.3/7.3 extends through three stories of wood-framed <br /> structure. Calculations substantiating that shrinkage of the structure will not adversely <br /> affect the performance of the elevator are recommended. Elevator rails should be <br /> evaluated for induced axial loads or provided with connections that allow for vertical <br /> differential movement. See IBC Section 2304.3.3. <br /> 12.The Roof Framing Plan on Sheet S2.5 does no show an elevator hoist beam for the elevator <br /> at Grid F.3/7.3. Verify if a beam is required. Provide details as needed for the connection <br /> between the beam and the supporting wood-framed wall. Framing connections are required <br /> to provide a minimum positive connection capacity per ASCE 7-10 Section 1.4.4. Posts or <br /> other framing should be specified to provide a load path to the foundation. Documentation <br /> substantiating the connections and framing should be submitted for review. See IBC <br /> Sections 1603.1, 1604.1, and 1604.4. <br /> © 3200 Cedar Street © 425.257.8800 O everettpw@everettwa.gov <br /> Everett, WA 98201 425.257.8882 fax everettwa.gov <br />
The URL can be used to link to this page
Your browser does not support the video tag.