• • <br /> Mr. Charlie Morgan, Jr. <br /> Charles Morgan &Associates <br /> Plan Check Number: B1805-043, Second Review <br /> October 24, 2018 <br /> concurrently with other loads should be submitted for review. The calculations should <br /> include the evaluation of deflection limits per IBC Section 1607.9.1. The design shall <br /> consider concurrent multi-directional loading as determined by the elevator <br /> manufacturer. See IBC Sections 1604.2 and 1605. <br /> d. The connections between the elevator guide rails and the structural framing are typically <br /> the responsibility of the engineer-of-record for the building system. At a minimum, <br /> connection details between the rail bracket and structural framing are required. <br /> Calculations and details for the elevator connections to the structural framing should be <br /> submitted for review. The design shall consider concurrent multi-directional loading as <br /> determined by the elevator manufacturer. The required locations and maximum spacing <br /> for the connection points should be specified in the structural drawings. See IBC <br /> Section 107.2.1 and 1604.4. <br /> e. The structural calculations shall be performing using the appropriate load combinations <br /> including live and seismic loading per IBC Section 1605.2 or 1605.3. In addition, <br /> documentation shall be submitted verifying the nominal loads have been increased for <br /> impact effects per IBC Section 1607.9.1. The application of the live load factors in the <br /> LRFD load combinations does not satisfy this requirement. <br /> f. The elevator shaft at Grid F.3/7.3 extends through three stories of wood-framed <br /> structure. Calculations substantiating that shrinkage of the structure will not adversely <br /> affect the performance of the elevator are recommended. Elevator rails should be <br /> evaluated for induced axial loads or provided with connections that allow for vertical <br /> differential movement. See IBC Section 2304.3.3. <br /> 12.The Roof Framing Plan on Sheet S2.5 does no show an elevator hoist beam for the elevator <br /> at Grid F.3/7.3. Verify if a beam is required. Provide details as needed for the connection <br /> between the beam and the supporting wood-framed wall. Framing connections are required <br /> to provide a minimum positive connection capacity per ASCE 7-10 Section 1.4.4. Posts or <br /> other framing should be specified to provide a load path to the foundation. Documentation <br /> substantiating the connections and framing should be submitted for review. See IBC <br /> Sections 1603.1, 1604.1, and 1604.4. <br /> © 3200 Cedar Street © 425.257.8800 O everettpw@everettwa.gov <br /> Everett, WA 98201 425.257.8882 fax everettwa.gov <br />