Aug. 31. 2004 3:46PM CHARLES MORGAN & ASSOC. No. 0044 P. 6 <br /> . • Grandview Homes, LLC JN 99040 <br /> February 16, 1999 Page 4 <br /> All slabs-on-grade should be underlain by a capillary break or drainage layer consisting of a <br /> minimum 4-inch thickness of coarse, free-draining structural fill with a gradation similar to that <br /> discussed later in Permanent Foundation and Retaining Walls. In areas where the passage of <br /> moisture through the slab is undesirable, a vapor barrier, such as a 6-mil plastic membrane, should <br /> be placed beneath the slab. Additionally, sand should be used in the fine-grading process to <br /> reduce damage to the vapor barrier, to provide uniform support under the slab, and to reduce <br /> shrinkage cracking by improving the concrete curing process. <br /> Isolation joints should be provided where the slabs intersect columns and walls. Control and <br /> expansion joints should also be used to control cracking from expansion and•contraction. Saw cuts <br /> or preformed strip joints used to control shrinkage cracking should extend through the upper one- <br /> fourth of the slab. The spacing of control or expansion joints depends on the slab shape and the <br /> amount of steel placed in it. Reducing•the water-to-cement ratio of the concrete and curing the <br /> concrete, by preventing the evaporation of free water until cement hydration occurs, will also <br /> reduce shrinkage cracking. <br /> Permanent Foundation and Retaining Walls <br /> Retaining walls backfilled on only one side should be designed to resist the lateral earth pressures <br /> imposed by the soil they retain. The following recommended design parameters are for walls that <br /> restrain•level backfill: <br /> a aroeter:: . Design Value <br /> Active Earth Pressure* 35 pcf <br /> Passive Earth Pressure 400 pcf <br /> Coefficient of Friction 0.40 <br /> Soil Unit Weight 140 pcf <br /> _ <br /> Where: (i) pcf Is pounds per cubic foot, and (li) active and <br /> passive earth pressures are computed using the equivalent fluid <br /> pressures. <br /> *For a restrained wall that cannot deflect at least 0.002 times Its <br /> height,a uniform lateral pressure equal to 10 psf times the height <br /> of the wall should be added to the above active equivalent fluid <br /> pressure. <br /> The values given above are to be used to design permanent foundation and retaining wails only. <br /> The passive pressure given is appropriate for the depth of level structural fill placed in front of a <br /> retaining or foundation wall only. We recommend a safety factor of at least 1.5 for overturning and <br /> sliding, when using the above values to design the walls. Restrained wall soil parameters should <br /> be utilized for a distance of 1.5 times the wall height from corners in the wails. <br /> The design values given above do not Include the effects of any hydrostatic pressures behind the <br /> walls and assume that no surcharges, such es those caused by slopes, vehicles, or adjacent <br /> foundations will be exerted on the walls. If these conditions exist, those pressures should be added <br /> to the above lateral soil pressures. Where sloping backfill is desired behind the walls, we will need <br /> to be given the wall dimensions and the slope of the backfill in order to provide the appropriate <br /> design earth pressures: The surcharge due to traffic loads behind _a wall can typically be <br /> SGEOTECH CONSULTANTS.INC. / <br />