My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10721 19TH AVE SE 2023-04-07
>
Address Records
>
19TH AVE SE
>
10721
>
10721 19TH AVE SE 2023-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2023 2:36:50 PM
Creation date
4/7/2023 2:34:25 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10721
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Jeff Heilman,Development Technician--Public Works Department <br /> RE: Owner: Wong-- 19'1'Avenue SE <br /> ne 20 2018 <br /> ages <br /> b) The structure is assigned to Seismic Design Category(SDC) D. The walls shall be designed <br /> as special reinforced concrete shear walls(SRCSW)with a response modification factor of <br /> R=5 per ASCE 7-10 Table 12.2-1 Item A.1. The forces from the wood-framed walls above <br /> shall be scaled per ASCE 7-10 Section 12.2.3.1 Item 1. See IBC Section 1613.1. <br /> c) The walls shall comply with the reinforcement requirements for SRCSW per ACI 318-14 <br /> Section 18.10. See IBC Section 1901.2. <br /> d) Performance of the lateral system requires rotational resistance of the concrete walls at their <br /> bases by the foundation system. Calculations shall be submitted substantiating that the <br /> foundation system provides adequate strength and stiffness to resist design loads from the <br /> structure above. See IBC Section 1604.1, 1604.4,and 1613.1, and ASCE 7-10 Section 12.7.3. <br /> e) Continuing with the previous comment,the foundation system shall comply with the seismic <br /> detailing requirements of ACI 318-14 Sections 1813.2.1. The thickened slab edge shall be <br /> designed as a grade beam per Section 18.13.3.1 as needed to provide flexural restraint for and <br /> resist uplift on the wall piers. See IBC Section 1901.2. <br /> f) The thickness of the wall is not specified on Sheet S2.1 or Detail 12/S4.2. The wall thickness <br /> should be specified for clarity. See IBC Section 1603.1. <br /> g) The holdowns are anchored in thin walls with minimal resistance to breakout. It is <br /> recommended that the top of the wall be reinforced per the requirements of ACI 318-14 <br /> Section 10.7.6.1.6. See also comments below regarding the hold own design. See IBC Section <br /> 1901.2. <br /> a) See added sheet C-28 for garage portal design. <br /> b) See response to a) <br /> c) See response to a) <br /> d) See response to a) <br /> e) The holdown anchor bolts are embedded into the footing. The footing is design to resist <br /> uplift from the wall piers. <br /> J) Sheet S2.1 has been updated to specify the wall thickness. <br /> g) The holdown are embedded into the footing. See added sheet C-39 for anchor bolt <br /> calculations. <br /> 16. The structure includes 2-foot long wood shear walls at the first story on the south side per Sheets <br /> S2.1 and A2.1.The following comments should be addressed: <br /> a) Structural calculations page C-25 indicates the wall piers are 2.2-feet long.At least one pier <br /> in each bay is limited to 2 feet. The calculations should be revised considering the actual <br /> length. <br /> b) Continuing with the previous comment,the calculation of the holdown force is based on the <br /> gross wall length. The placement of the holdowns significantly reduces the moment arm and <br /> increased the required tension force,especially for the side with the(4)-stud boundary <br /> element per Detail I2/S4.2. The holdown force should be revised. <br /> a) The shearwall lengths have been updated. <br /> b) The moment arm lengths have been revised. See calculation sheet C-26. <br /> 17. The orthogonal shear walls at the southwest corner of the structural appear to share a holdown per <br /> the foundation plan on Sheet S2.1. The holdown is positioned to provide direct resistance for the <br />
The URL can be used to link to this page
Your browser does not support the video tag.