My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10721 19TH AVE SE 2023-04-07
>
Address Records
>
19TH AVE SE
>
10721
>
10721 19TH AVE SE 2023-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2023 2:36:50 PM
Creation date
4/7/2023 2:34:25 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10721
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
•► <br /> {Mr., Ms.} First Last Name <br /> Company <br /> Plan Check Number: Number, First Review <br /> Month Day, Year <br /> beam should include the cumulative loads from both the second and third story shear wall <br /> holdown forces. The values of the point loads should be clarified. <br /> f) The load combinations do not appear to include the vertical seismic component per ASCE <br /> 7-10 Sections 12.4.2.2 and 12.4.3.2. See the controlling load combinations on page B-13 <br /> as an example. The beam design should be revised. See IBC Section 1613.1. <br /> 13.The second floor framing specifies TJI 210 joists at the hallway adjacent to the stairway. This <br /> framing is specified as"32"on page B-14 of the structural calculations. Calculations <br /> substantiating the joist design shall be submitted for review. See IBC Section 1604.1. <br /> Lateral System: <br /> 14.The wind loads used in the lateral analysis on pages C-18 through C-27 appear to be the <br /> allowable values from page C-7. The values do not appear to be ultimate loads as indicated in <br /> the "Shear Wall Loads and Summary"tables. The values of the loads should be verified and <br /> the calculations revised as needed. See IBC Section 1604.4. <br /> 15.The two-foot long first-story wood shear walls on the south building elevation are supported by <br /> concrete wall piers that are approximately 4-feet tall. The concrete walls are approximately <br /> one-half the story height with a 2:1 aspect ratio. In addition, the walls project above the slab- <br /> on-grade while the typical foundation wall does not project above the slab per Detail 10/S3.0. <br /> The walls are part of the seismic force resisting system and must be designed accordingly. <br /> The following comments should be addressed: <br /> a) Calculations substantiating the design of the concrete piers shall be submitted for review. <br /> See IBC Sections 1604.1 and 1604.4. <br /> b) The structure is assigned to Seismic Design Category (SDC) D. The walls shall be designed <br /> as special reinforced concrete shear walls (SRCSW) with a response modification factor of <br /> R=5 per ASCE 7-10 Table 12.2-1 Item A.1. The forces from the wood-framed walls above <br /> shall be scaled per ASCE 7-10 Section 12.2.3.1 Item 1. See IBC Section 1613.1. <br /> c) The walls shall comply with the reinforcement requirements for SRCSW per ACI 318-14 <br /> Section 18.10. See IBC Section 1901.2. <br /> d) Performance of the lateral system requires rotational resistance of the concrete walls at <br /> their bases by the foundation system. Calculations shall be submitted substantiating that <br /> the foundation system provides adequate strength and stiffness to resist design loads from <br /> the structure above. See IBC Section 1604.1, 1604.4, and 1613.1, and ASCE 7-10 Section <br /> 12.7.3. <br /> e) Continuing with the previous comment, the foundation system shall comply with the <br /> seismic detailing requirements of ACI 318-14 Sections 1813.2.1. The thickened slab edge <br /> shall be designed as a grade beam per Section 18.13.3.1 as needed to provide flexural <br /> restraint for and resist uplift on the wall piers. See IBC Section 1901.2. <br /> f) The thickness of the wall is not specified on Sheet S2.1 or Detail 12/S4.2. The wall <br /> thickness should be specified for clarity. See IBC Section 1603.1. <br /> g) The holdowns are anchored in thin walls with minimal resistance to breakout. It is <br /> recommended that the top of the wall be reinforced per the requirements of ACI 318-14 <br /> Section 10.7.6.1.6. See also comments below regarding the holdown design. See IBC <br /> Section 1901.2. <br /> ZjfiD <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8810 • Fax (425) 257- <br />
The URL can be used to link to this page
Your browser does not support the video tag.