My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1708 25TH ST A B 2023-04-07
>
Address Records
>
25TH ST
>
1708
>
1708 25TH ST A B 2023-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2023 3:07:46 PM
Creation date
4/7/2023 3:06:50 PM
Metadata
Fields
Template:
Address Document
Street Name
25TH ST
Street Number
1708
Unit
A B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> a. Special Reinforced Concrete Shear Walls used for lateral resistance are required to <br /> adhere to the special design and detailing requirements in ACI 318-14 Sec 18.7. <br /> Requirements such as minimum column dimensions, tie spacing, shear capacity of the <br /> column do not appear to meeting these criteria as shown on Details 1A and 2A on <br /> Sheet 3 of the permit drawings. Please provide permit calculations consistent with <br /> the requirements for detailing and lateral loading of the lateral forces. <br /> b. The revised permit calculation package do not contain analyses for the glulam beams <br /> in question for loading condition of gravity loading, the applied overturning force <br /> couple from the wood shear walls, and load delivery as a drag strut to the special <br /> concrete shear walls. Please refer to IBC 1605.1 and ASCE 7-10 Sec 12.3.3.3. <br /> 25.This comment has not been completely addressed. The previous response needs to be <br /> transferred to the contract documents. Please identify these locations on the drawings or <br /> provide a means for the contractor or builder to obtain these loads/capacities in order to <br /> determine where this condition occurs on the project. IBC 107.2.1 and 1603.1.8. <br /> 26.This comment has been addressed. <br /> 27.This comment has not been completely addressed. From the previous response, it <br /> appears to imply that the common/party wall on Sheet 8 is not a wood shear wall. Please <br /> confirm as it appears from Sheet 5 of the construction drawings that the common wall has <br /> a SW-1 designation. Please clarify if sheathing is required to maintain continuity and if <br /> not, please describe the load path to accommodate the shear transfer from the roof <br /> diaphragm to wall. <br /> In order for the processing of your application to continue, it will be necessary to provide the <br /> Building Division with two new sets of revised construction documents reflecting the corrections <br /> requested. Please include a response letter which indicates how the corrections were resolved. <br /> All codes cited refer to the 2015 International Building Code (IBC), 2015 International Existing <br /> Building Code (IEBC), the 2015 International Fire Code (IFC), the 2015 International Mechanical <br /> Code (IMC), and/or the 2015 Washington State Energy Code (WSEC), as amended by the State <br /> of Washington and adopted by the City of Everett. The current IBC referenced standard for <br /> accessible design is the 2009 "Accessible and Usable Buildings and Facilities" (ICC/ANSI <br /> A117.1). Federal ADA regulations and standards may be more restrictive. <br /> O 3002 Wetmore Ave. © 425.257.8800 • everettpw@everettwa.gov <br /> Everett, WA 98201 425.257.8882 fax everettwa.gov <br />
The URL can be used to link to this page
Your browser does not support the video tag.