Laserfiche WebLink
SOLAR MODULE SPECIFICATIONS VOLTAGE RISE IN Q CABLE FROM THE MICROINVERTERS TO THE JUNCTION BOX �( <br /> MANUFACTURER/MODEL Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) Lumio <br /> VMP 37.13 V FOR BRANCH CIRCUIT #1 OF 13 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.76% SMART ENERGY TODAY <br /> IMP 10.77 A FOR BRANCH CIRCUIT #2 OF 12 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.65% (SET) <br /> 1550 DIGITAL DR,LEHI,UT <br /> VOC 45.3 V FOR BRANCH CIRCUIT #3 OF 10 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.46% 84043,USA <br /> ISC 11.14 A VOLTAGE RISE FROM THE JUNCTION BOX TO THE IQ COMBINER BOX 4C <br /> TEMP. COEFF. VOC -0.27%/K VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) <br /> PTC RATING 376.55 W = (1.21 AMP X 13) X (0.00129 OHMS/FT) X (45 FT X 2) <br /> MODULE DIMENSION 74"(L)x 41.1"(W) <br /> PANEL WATTAGE 40o w = 15.73 AMPS X 0.00129 OHMS/FT) X 90 FT SYSTEM INFO <br /> = 1.83 VOLTS <br /> INVERTER SPECIFICATIONS (35)O CELLS <br /> %VRISE = 1.83 VOLTS - 240 VOLTS = 0.76% Q.PEAK DUO BLK ML-G10+ <br /> MANUFACTURER/MODEL ENPHASE IQ8PLUS-72-2-US (240V) ° (400w) <br /> THE VOLTAGE RISE FROM THE JUNCTION BOX TO THE IQ COMBINER BOX 4C IS 0.76% (35)ENPHASE <br /> MAX DC SHORT CIRCUIT CURRENT 15 A IQ8PLUS-72-2-US(240V) <br /> CONTINUOUS OUTPUT CURRENT 1.21 A VOLTAGE RISE FROM THE IQ COMBINER BOX 4C TO THE FUSED AC DISCONNECT DC SYSTEM SIZE:14.000kWDC <br /> AC SYSTEM SIZE:10.500 kWAC <br /> AMBIENT TEMPERATURE SPECS VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) <br /> RECORD LOW TEMP -5°C = (1.21 AMP X 35) X (0.00051 OHMS/FT) X (5 FT X 2) <br /> AMBIENT TEMP (HIGH TEMP 2%) 26°C = 42.35 AMPS X 0.00051 OHMS/FT) X 10 FT REVISIONS <br /> CONDUIT HEIGHT 7/8" = 0.22 VOLTS DESCRIPTION DATE REV <br /> ROOF TOP TEMP 90°C %VRISE = 0.22 VOLTS + 240 VOLTS = 0.09% REVISION 12/16/2022 A <br /> CONDUCTOR TEMPERATURE RATE 48°C THE VOLTAGE RISE FROM THE IQ COMBINER BOX 4C TO THE FUSED AC DISCONNECT IS 0.09% <br /> MODULE TEMPERATURE COEFFICIENT OF VOC -0.27%/K VOLTAGE RISE FROM THE FUSED AC DISCONNECT TO THE MSP <br /> PERCENT OF VALUES NUMBER OF CURRENT CARRYING VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) PROJECT NAME&ADDRESS <br /> CONDUCTORS IN EMT <br /> 0.80 4-6 = (1.21 AMP X 35) X (0.00051 OHMS/FT) X (5 FT X 2) <br /> 0.70 7-9 = 42.35 AMPS X 0.00051 OHMS/FT) X 10 FT < <br /> 0.50 10-20 1 = 0.22 VOLTS D <br /> %VRISE = 0.22 VOLTS _ 240 VOLTS = 0.09% o <br /> THE VOLTAGE RISE FROM THE FUSED AC DISCONNECT TO THE MSP IS 0.09% N <br /> m o <br /> TOTAL SYSTEM VOLTAGE RISE FOR ALL WIRE SECTIONS o w s <br /> 0 <br /> 0.76% + 0.76% + 0.09% + 0.09% = 1.70% U o <br /> W � co <br /> m 0 w Lo <br /> Ln <br /> Z w w o <br /> Q J <br /> U) O d <br /> 1-- <br /> Q <br /> _0 <br /> (V <br /> 0 <br /> Lf) <br /> CV <br /> DATE: 12/16/2022 <br /> SHEET NAME <br /> SPECIFICATIONS <br /> & NOTES <br /> SHEET SIZE <br /> ANSI B <br /> 11" X 17" <br /> SHEET NUMBER <br /> --] <br /> PV-8 <br />