My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3800 RIVERFRONT BLVD Geotech Report 2023-05-04
>
Address Records
>
RIVERFRONT BLVD
>
3800
>
Geotech Report
>
3800 RIVERFRONT BLVD Geotech Report 2023-05-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/4/2023 8:10:16 AM
Creation date
5/4/2023 7:16:17 AM
Metadata
Fields
Template:
Address Document
Street Name
RIVERFRONT BLVD
Street Number
3800
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
365
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> March 26, 2019 <br /> H WA Project No. 2015-061-21 Task 600-7 <br /> compaction should only be attempted during the dry summer months. Other types of gas'barrier <br /> should be installed in areas requiring construction outside of the dry summer months. <br /> If the above-mentioned approved LPSB stockpile is not sufficient quantity to meet the project <br /> LPSB needs, laboratory testing will be required to verify that either imported or in-place LPSB <br /> meets the intent of the material. For imported LBSB, we recommend that the proposed source <br /> location be tested and approved prior to importation of LPSB material. The testing protocol and <br /> frequencies for proposed imported LPSB are provided in Table 4. If the in-place soils are to be <br /> used as LPSB, testing along the roadway will be required to verify that the soils meet the intent <br /> of LPSB and are compacted to a sufficient level to achieve a permeabilityof l x 10-5 cm/sec or <br /> p <br /> less. The testing protocol and frequencies for in-place soils to be used as LPSB are provided in <br /> Table 4. <br /> Table 4 <br /> LPSB Testing Requirements <br /> Required Material Testing Frequencies <br /> Imported In Place <br /> Test Designation Low Permeability Soil Barrier Low Permeability Soil Barrier <br /> (LPSB) (LPSB) <br /> Density Test(ASTM Not Applicable 1 test every 200 feet of roadway <br /> * <br /> D 6938) <br /> Gradation 3 initial tests for evaluation by 1 test every 200 feet of roadway* <br /> (ASTM D 422) the Engineer prior to placement <br /> Moisture/Density 3 initial tests for evaluation by 1 test every 200 feet of roadway* <br /> i (ASTM D 1557) the Engineer prior to placement <br /> Hydraulic 1 initial test on a remolded 1 test every 200 feet of roadway on <br /> Conductivity composite sample, at 1 to 3 a remolded composite sample, at 1 <br /> (ASTM D 5084) percent over optimum moisture to 3 percent over optimum <br /> content, and compacted to 93% moisture content, and compacted <br /> of the uncorrected laboratory to the level determined through <br /> maximum drydensity, densitytestingat the subject <br /> J <br /> determined by ASTM D 1557 location* <br /> Moisture Content Daily as processed <br /> (ASTM D 2216) <br /> * Samples and compaction testing of in place soils to be obtained at the approximate midpoint of <br /> the existing layer. <br /> Y <br /> I <br /> Geotechnical Report Revision 3 26 2019.doc 23 HWA GEOSCIENCES INC. <br />