Laserfiche WebLink
1 r--------------------------- 8 <br /> 1 �\ Shielded I LINE <br /> #2 <br /> 1 \�#24 AWG <br /> CTs(Untwisted Pairs) I M <br /> 2 r______I LOAD <br /> 1 I I <br /> I 1 <br /> I I I <br /> I I 1 <br /> EnphaselQ 1 <br /> Junction 3 Combiner Panel 4 1 4 I <br /> 1 Box ———1 <br /> 1 200A MAIN 7 <br /> I 20A -————————————————————— 200A BUS <br /> 15A --, I <br /> O 2 I I I <br /> I 30A <br /> 1 I I I <br /> 30AOCPD <br /> 3 --—————————— — —J--------------- --- -----� 1 <br /> — — <br /> --- -- ---------- 1 <br /> I <br /> I <br /> 4 L— <br /> 5 <br /> 1 Combined <br /> I Inverter Max <br /> 1 Output with <br /> Safety Factor <br /> 24.2 Amps <br /> IV <br /> 5 <br /> Module Design Temp ARRAY SPECIFICATIONS CONDUIT AND CONDUCTOR SCHEDULE <br /> Ratings <br /> REC405AA Pure Black Hot 29°C Combined Array Specs TAG DESCRIPTION OF CONDUCTOR TYPE COND. NUMBER OF CONDUIT CONDUIT <br /> Imp 9.56 A Nom 24°C GAUGE CONDUCTORS TYPE SIZE <br /> Isc 10.30 A Cold -17°C 40055 W REC Modules <br /> 6kW 1 Cables Listed with Module 12 AWG 2 Black N/A N/A Vmp 42.4 V TcVoc -.24%/°C 2 THHN THWN-2 12 AWG 1 B(L1), 1 R(L2), 1 G#12(EGC) EMT 3/4" <br /> 16 Modules <br /> Voc 48.9 V MaxVoc 53.83 V (1)Circuits of(6)Modules 3 THHN THWN-2 12 AWG 2 B(1-1), 2 R(1-2), 1 G#12(EGC) EMT 3/4"4 THHN THWN-2 8 AWG 1 B(L1), 1 R(L2), 1 W(NEUT), 1 G#10(GND) EMT 3/411 <br /> (1)Circuits of(10)Modules <br /> (1)Micro-inverter per module. 6 GROUNDING ELECTRODE COND 6 AWG Bare 1 CU N/A N/A <br /> Each String AC Circuit <br /> Inverter 10 Nominal Voltage O EQUIPMENT SCHEDULE <br /> Output 240 V Imax <br /> Output A 1.21 A 240 V TAG EQUIPMENT LOCATION DESCRIPTION <br /> String A 12.10 A 19.36 A <br /> 1 SOLAR PV MODULE South, East&West Roofs of House 6.48 kW System: 16 REC Modules;405W Each; REC405AA Pure Black <br /> 2 PV ARRAY South, East&West Roofs of House 16 Modules:See Array Specifications for String Info <br /> Each String 3 MICRO-INVERTERS Underneath Each Module 16 Enphase Micro-inverters: 1 IQ8PLUS-72-2-US per Module; RSD Compliant <br /> 4 JUNCTION BOX Mounted Underneath Arra NEMA 3R <br /> Inverter 6 5 AC COMBINER PANEL Southwest Exterior House Wall 240V Enphase Combiner Panel 4; NEMA 3R; 1 15A Breakers; 1 20A Breaker; 1 30A Breaker <br /> Output 240 V 7 200 AMP MAIN SERVICE PANEL Southwest Interior House Wall 240 VAC, 200AMP MAIN,200AMP MAIN <br /> Output A 1.21 A 8 UTILITY METER Southwest Exterior House Wall Existing Meter#: 1000378232 <br /> String A 7.26 A <br /> _ One-Line Standard Electrical Diagram for SYSTEM SIZE AE JOB NO. DWG NO REVISION <br /> ' • Small-Scale, Single-Phase PV System 6.48kW 22-10359-R E1.1 1 Drawn By: Chiva Chun <br /> 969 S Nebraska St <br /> ARTISAN Seattle, WA 98108 Site Name: Ciera Cox Photovoltaic System <br /> 206-557-4215 Site Address: 4319 Crescent Ave Everett,WA 98203 Scale: NTS Sheet 1 Date: 2/16/2023 Checked By: <br /> System AC Size: 6.48kW Solar Array <br />