My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1010 SE EVERETT MALL WAY AMERICAN RED CROSS 2023-05-10
>
Address Records
>
SE EVERETT MALL WAY
>
1010
>
AMERICAN RED CROSS
>
1010 SE EVERETT MALL WAY AMERICAN RED CROSS 2023-05-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/10/2023 11:31:39 AM
Creation date
5/10/2023 11:24:47 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1010
Tenant Name
AMERICAN RED CROSS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ALIVE design group <br /> ROBISON <br /> ENGINEERING,INC <br /> 00000°o <br /> ,ti s <br /> CALCULATIONS SCHEDULES <br /> C7o/0NAI_ 2p22 <br /> WATER SOURCE HEAT PUMP - SCHEDULE <br /> EQUIP HEATING COOLING ELECTRICAL MOTOR BASIS OF DESIGN <br /> NO. SERVICE TYPE VOLTAGE HP (1)(2)(3) <br /> CAPACITY AIRFLOW EAT DEC H2O EWT DEC MAX H2O CAPACITY AIRFLOW EAT H2O EWT MAX <br /> MBH CFM F FLOW F PD (FT) MBH CFM DECIF FLOW DEC F H2O PD <br /> WSHP-1 OFFICE FCU 50.3 1400 60 6.4 180 5.0 41.2 1400 76 6.4 45 10 460V/3P 0.5 TRANE GEHE0424 <br /> WSHP-2 OFFICE FCU 41.4 1200 60 5.4 180 5.0 33.3 1200 76 5.4 45 10 460V/3P 0.5 TRANE GEHE0354 <br /> WSHP-3 OFFICE FCU 57.7 1600 60 7.3 180 �533 <br /> 1600 76 7.3 45 10 460V 3P 0.5 TRANE GEHE0484 <br /> WSHP-4 OFFICE FCU 41.4 1200 60 5.4 180 1200 76 5.4 45 10 460V/3P 0.5 TRANE GEHE0354 }; <br /> (2) EXTERIOR GRILLE IN GUESTROOMS SHALL BE THE ARCHITECTURAL GRILLE. COORDINATE STYLE AND COLOR WITH ARCHITECT. i O <br /> (3) ALTERNATE BID: CLIMATE MASTER. <br /> N <br /> (4) PROVIDE MERV 6 AIR FILTERS PER WSMC 605.4 I ` <br /> W <br /> U) '0 <br /> >CID.N <br /> VENTILATION CALCULATIONS I N rn N <br /> CFM CFM CFM CFM DIFFUSER SCHEDULE C <br /> ROOM AREA, OCCUPANTS, CFM/SQ CFM/ O Q <br /> SF PEOPLE FT PEOPLE (AREA) (OCC) REQUIRED PROVIDED AIRFLOW FACE SIZE, L N <br /> CALLOUT DESCRIPTION RANGE, CFM IN BASIS OF DESIGN (1)(2) I 00 <br /> LOBBY 325 3 .06 5 20 15 35 35 �../ <br /> CD-1 CEILING DIFFUSER 0-600 24.24 PRICE SPD 041 <br /> OFFICE 2400 24 .06 5 144 120 264 265 CD-2 CEILING DIFFUSER 0-200 12X12 PRICE SPD <br /> �DATA ROOM 80 1 .12 7.5 10 8 17 20 RG-1 RETURN GRILLE 0-2177 24X24 PRICE RAS (3) LU w <br /> BREAK ROOM 300 3 .12 7.5 36 23 58 60 NOTES: (1) ALL DIFFUSERS, REGISTERS, AND GRILLES SHALL BE FACTORY PRIMED U-11 <br /> FOR CUSTOM PAINTING BY OTHERS. W <br /> STORAGE 460 - .06 - 28 - 28 30 <br /> (2)PROVIDE OBD FOR BALANCINGO <br /> I �/� <br /> TOTAL OUTSIDE AIR PROVIDED 410 (3)PROVIDE PRICE RAC RETURN AIR CANOPY. V <br /> _ O <br /> �L <br /> E <br /> Q <br /> WASHINGTON STATE ENERGY CODE I <br /> 1. HVAC THERMOSTATS SHALL BE SET TO MAINTAIN A MINIMUM DEADBAND OF 5'F IN AREAS SERVED AS REQUIRED <br /> PER WSEC C403.2.4.2. <br /> 2. PER WSEC, ALL DUCTS SHALL BE INSULATED AS FOLLOWS: <br /> DUCT INSULATION SCHEDULE <br /> R-VALUE <br /> CODE DUCT SYSTEM DUCT LOCATION AND USE (1)(2)(3) MATERIAL (MIN. <br /> INSTALLED) <br /> Z 2800 CFM INSIDE CONDITION SPACE AND UPSTREAM OF MINERAL-WOOL 16.0 <br /> AUTOMATIC SHUTOFF DAMPER BLANKET <br /> WSEC TABLE OUTSIDE AIR >- 2800 CFM INSIDE CONDITION SPACE AND DOWNSTREAM OF MINERAL-WOOL <br /> C403.10.1.1 (4) AUTOMATIC SHUTOFF DAMPER TO HVAC UNIT UNIT OR ROOM BLANKET 8'0 07/28/2022 <br /> < 2800 CFM INSIDE CONDITION SPACE MINERAL-WOOL <br /> BLANKET 7.0 I CONSTRUCTION <br /> OUTSIDE THE BUILDING (OUTDOOR AND EXPOSED TO WEATHER) WHICH MINERAL-WOOL DOCUMENTS I <br /> INCLUDE ATTICS ABOVE INSULATION CEILINGS, PARKING GARAGE AND BLANKET 8.0 J <br /> CRAWL SPACE <br /> UNCONDITIONED SPACE (ENCLOSED BUT NOT IN THE BUILDING MINERAL-WOOL 6.0 <br /> SUPPLY AIR & CONDITIONED ENVELOPE) BLANKET <br /> RETURN AIR (4)UNCONDITIONED SPACE WHERE THE DUCT CONVEYS AIR THAT IS Revisions <br /> WITHIN 157 OF THE AIR TEMPERATURE OF THE SURROUNDING MINERAL-WOOL 3.3 <br /> UNCONDITIONED SPACE (5) BLANKET <br /> No. Description Date <br /> WHERE LOCATED IN THE BUILDING ENVELOPE ASSEMBLY MINERAL-WOOL 16.0 0 100/SUBMITTAL 7/28/22 <br /> BLANKET 2 REVISIONS 11/17/22 <br /> WSEC TABLE WITHIN CONDITIONED SPACE WHERE SUPPLY DUCT CONVEYS AIR <55°FMINERAL-WOOL <br /> C403.10.1.2 OR >1057' BLANKET 3.3 <br /> SUPPLY AIR (4)WITHIN CONDITIONED SPACE THAT THE DUCT DIRECTLY SERVES WHERE MINERAL-WOOL 0.0 <br /> SUPPLY DUCT CONVEYS AIR <557 OR >1057 BLANKET <br /> WITHIN CONDITIONED SPACE WHERE SUPPLY DUCT CONVEYS AIR >55°FMINERAL-WOOL 0.0 <br /> OR <1057' BLANKET <br /> RETURN OR WITHIN CONDITION SPACE, DOWNSTREAM OF AN ENERGY RECOVERY MINERAL-WOOL 8 0 <br /> EXHAUST AIR MEDIA, UPSTREAM OF AUTOMATIC SHUTOFF DAMPER BLANKET <br /> RELIEF OR CONDITION SPACE AND DOWNSTREAM OF AN AUTOMATIC SHUTOFF MINERAL-WOOL 16 <br /> EXHAUST AIR DAMPER BLANKET <br /> NOTES <br /> (1) DUCT INSULATION SHALL COMPLY WITH WSEC <br /> (2) INSULATION SHALL HAVE A MAXIMUM FLAME SPREAD INDEX OF 25 AND MAXIMUM SMOKE <br /> DEVELOPED INDEX OF 50 PER WSEC 604.3 <br /> (3) EXTERAL DUCT INSULATION IS IDENTIFIABLE PER WSEC 604.7 <br /> (4) VAPOR RETARDER IS INSTALLED ON SUPPLY AND OUTSIDE AIR DUCT PER WSEC 604.11 <br /> (5) CONDENSATION CONTROL FOR DUCTWORK <br /> American Red <br /> 3. MOTORIZED DAMPERS: PER WSEC C403.7.8.1 PROVIDE MOTORIZED DAMPERS ON ALL OUTSIDE AIR INTAKES, EXHAUST Cross: Everett,WA <br /> OUTLETS AND RELIEF OUTLETS SERVING CONDITIONED SPACES WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS <br /> OFF. RETURN AIR DAMPERS SHALL BE EQUIPPED WITH MOTORIZED DAMPERS. SEE WSEC C402.4.5.2 FOR EXCEPTIONS <br /> AND ADDITIONAL REQUIREMENTS. <br /> Owner <br /> 1010 SE Everett Mall Way <br /> Suite 202 <br /> Everett,WA 98028 <br /> Project Number <br /> 22001 D <br /> Dale <br /> 11/17/2022 <br /> SCHEDULES <br /> M0. 1 <br /> This drawing is the property of LIVE design group pc,and is not to be reproduced,copied,or altered in whole or in part or used for any purpose without the approval of LIVE design group pc,and is to be returned upon request. 331 p205.870.30901 f205.870.30931 www.LIVEdesigngroup.com 7/26/20224:30:20 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.