My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2911 CALIFORNIA ST 2023-09-12
>
Address Records
>
CALIFORNIA ST
>
2911
>
2911 CALIFORNIA ST 2023-09-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2023 8:28:47 AM
Creation date
5/11/2023 2:25:45 PM
Metadata
Fields
Template:
Address Document
Street Name
CALIFORNIA ST
Street Number
2911
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PANELTEMP <br />I <br />PANELSCHEDULE <br />PROJECT: <br />EPS BUS GARAGE - DC BUS CHARGING <br />277/480V, 3Ph, 4W. <br />400 AMP <br />M.L.O. <br />3-Mar-23 <br />Ckt <br />No. <br />Description/ <br />Location <br />Load <br />(VA) <br />Load <br />Type <br />Amp <br />Pole <br />Phase <br />C.B. <br />Amp <br />C.B. <br />Pole <br />Load <br />(VA) <br />Load <br />Type <br />Description/ <br />Location <br />Ckt. <br />No. <br />1 <br />DC BUS CHARGER <br />#1 <br />10,000 <br />C <br />50 <br />3 <br />A <br />SPACE <br />2 <br />3 <br />- <br />10,000 <br />C <br />B <br />SPACE <br />4 <br />5 <br />- <br />10,000 <br />C <br />C <br />SPACE <br />6 <br />7 <br />DC BUS CHARGER <br />#2 <br />10,000 <br />C <br />50 <br />3 <br />A <br />SPACE <br />6 <br />9 <br />- <br />10,000 <br />C <br />B <br />SPACE <br />10 <br />11 <br />- <br />10,000 <br />C <br />C <br />SPACE <br />12 <br />13 <br />DC BUS CHARGER <br />#3 <br />10,000 <br />C <br />50 <br />1 3 <br />A <br />I <br />I <br />I <br />ISPACE <br />14 <br />15 <br />- <br />10,000 <br />C <br />B <br />I <br />SPACE <br />16 <br />17 <br />- <br />10,000 <br />C <br />C <br />SPACE <br />18 <br />19 <br />SPACE <br />A <br />SPACE <br />20 <br />21 <br />SPACE <br />S <br />SPACE <br />22 <br />23 <br />SPACE <br />C <br />SPACE <br />24 <br />25 <br />SPACE <br />A <br />SPACE <br />26 <br />27 <br />SPACE <br />B <br />SPACE <br />28 <br />29 <br />SPACE <br />C <br />SPACE <br />30 <br />31 <br />SPACE <br />A <br />ISPACE <br />32 <br />33 <br />SPACE <br />B <br />SPACE <br />34 <br />35 <br />SPACE <br />C <br />SPACE <br />36 <br />37 <br />SPACE <br />A <br />SPACE <br />38 <br />39 <br />SPACE <br />B <br />SPACE <br />40 <br />41 <br />SPACE <br />I C <br />I <br />I <br />ISPACE <br />42 <br />otal Connected Load: Ph A <br />Total Connected Load: Ph B <br />Total Connected Load: Ph C <br />Total Connected Load: <br />30,000 VA <br />30,000 VA <br />30,000 VA <br />90.0 KVA <br />108.3 AMPS <br />108 A <br />108 A <br />108 A <br />Total Demand Load: <br />112.5 KVA <br />135.3 AMPS <br />G General (Non -Continuous) <br />L Lighting <br />R Receptacles-to10KVA <br />ver 10 KVA <br />K Kitchen <br />H Heating <br />M Motors <br />LM Largest Motor <br />WH Water Healer <br />C Continuous General Load <br />Connected <br />Leads <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />90,000 <br />90,000 VA <br />Subfed <br />Load.(S) <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 VA <br />Total Demand <br />Loads Factor <br />0 100% <br />0 125% <br />0 100% <br />0 50 % <br />0 100% <br />0 100% <br />0 100% <br />0 125% <br />0 125% <br />90,000 125% <br />90,000 VA <br />Demand <br />Load <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />112,500 <br />112,500 VA <br />Accessories: <br />- 22KAIC <br />-NEMA 3R <br />GENERAL NOTES <br />1. ALL WORKSHOWN OR CALLED FOR SHALL MEET THE REQUIREMENTS OF ALL LATEST ADOPTED STATE, LOCAL, <br />AND N.E.C. CODES AND ALL APPLICABLE NFPA STANDARDS. <br />2. CONTRACTOR SHALL COORIDINATE INSTALLATION WITH SNOHOMISH COUNTY PUD. PROVIDE ADDITIONAL <br />EQUIPMENT AND INSTALLATION REQUIRED BY SNOPUD. <br />UTILITY COSTS SHALL BE PAID DIRECTLY TO UTILITY BY OWNER. <br />CONTACT: ALLY BOWLES, 425.231.7266, AJBOWLES@SNOPUD.COM <br />3. ALL WIRING SHALL BE TYPE THHN OR THWN CONDUCTORS IN CONDUIT. <br />4. CONTRACTOR SHALL SECURE, SCHEDULE, AND PAY FOR ALL ELECTRICAL PERMITS. COORDINATE <br />REQUIREMENTS AND INSPECTIONS WITH THE CITY OF EVERETT. <br />5. ALL WORK SHALL BE SUBJECT TO OWNER'S APPROVAL AND ANY WORK (OR MATERIAL) THAT IS <br />NOT APPROVED SHALL BE REPLACED OR REWORKED UNTIL SUCH APPROVAL IS GIVEN. <br />6. ALL WORKMANSHIP AND MATERIAL SHALL BE GUARANTEED FOR ONE YEAR AFTER WRITTEN ACCEPTANCE. <br />400AMP DISC SW. <br />60OV, SUSE RATED <br />UTILITY METER/CT <br />300AMP FUSES <br />ENCLOSURE <br />22K AIC <br />UTILITY CO. PAD <br />(NEMA3R) <br />(NEMA3R) <br />MOUNTED <br />TRANSFORMER <br />M <br />TO UTILITY AVAIL FAULT CURRENT - <br />G <br />N <br />POLE - SEE <br />18,051 AMPS <br />SITE PLAN L <br />— <br />L <br />L <br />4 #500 KCMIL (AL) <br />(NEW 3-1/2"C) <br />4 #500 KCMIL (AL) <br />(IN EXISTING <br />#1/0 CU GEC TO (2) <br />CONDUIT) <br />EXIST. GROUND <br />RODS <br />PHASE I ONE -LINE DIAGRAM <br />NOT TO SCALE <br />PANELTEMP <br />400AMP, 480/277V <br />3PH, 4W <br />22KAIC <br />(NEMA 3R) <br />4 #500 KCMIL,(AL) <br />1 #3 Cu GND <br />(NEW 3-1/2"C) <br />M <br />N <br />M <br />O <br />M <br />O <br />W <br />N <br />G <br />m <br />W <br />a <br />d <br />JA <br />A <br />Electrical Consultants, Inc. <br />190153 Avenue West, Suite E <br />Lynnwood, Washington 98036 <br />Phone (4251775-1799 FAX (425) 774-9870 <br />EPS BUS GARAGE - <br />DC BUS CHARGING <br />STATIONS <br />PHASE <br />LOCATION- <br />EPS BUS GARAGE <br />2911 CALIFORNIA ST. <br />EVERETT, WA 98201 <br />— scuE: (Art«.,61 <br />_T oEswor: <br />SEAL <br />RISER DIAGRAM, <br />LOAD CALCULATIONS <br />MARCH 03, 2023 <br />SHEET —s <br />E0.00 <br />www.awaelec.com @ AWA, INC. <br />
The URL can be used to link to this page
Your browser does not support the video tag.