1321 SE EVERETT MALL WAY BASE FILE 2024-02-26
>
Address Records
>
SE EVERETT MALL WAY
>
1321
>
BASE FILE
>
1321 SE EVERETT MALL WAY BASE FILE 2024-02-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2024 9:58:02 AM
Creation date
5/12/2023 7:27:15 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1321
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VIBRATION ISOLATION / SEISMIC SCHEDULE LAST UPDATED: 09 29 22 <br />UNIT <br />TAG <br />SERVES <br />BASIS OF <br />DESIGN1 <br />DEFL <br />INCH <br />BASE <br />TYPE <br />SEISMIC <br />RESTRAINT <br />REMARKS <br />NA <br />ROOFTOP UNITS SMALL MFG CURB <br />- <br />- <br />SCREW TO CURB <br />2 4 10 <br />NA <br />DUCTWORK <br />CABLE RESTRAINT <br />S,8,15 <br />GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC...) WITH APPROVED SUBMITTALS <br />PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION &INSTALL PER MANUFACTURERS REQUIREMENTS <br />NOTE: CIB = COOLING TOWER BASE, CLB = CONCRETE INERTIA BASE <br />1 OR EQUAL ISOLATION (ISAT, MASON, VIBRACOUSTICS OR AS APPROVED), CONFIRM INSTALL METHOD WITH FIELD PRIOR TO ORDER <br />2 SEISMIC RATED CURB / ISOLATOR <br />3 USE HEIGHT SAVING BRACKETS FOR SPRING ISOLATORS <br />4 INTERNAL ISOLATION PROVIDED INTEGRAL WITH UNIT <br />5 PROVIDE FLEXIBLE HOSES FOR PIPING CONNECTIONS AT UNIT <br />6 WHERE DESIGNATED AS REQUIRED BY DESIGN ENGINEER BASED ON UNIT MOUNTING LOCATION IN ACOUSTICALLY/VIBRATIONALLY SENSATIVE AREAS <br />7 LAG BOLT (WOOD) OR WEDGE ANCHOR (CONCRETE) TO CONCRETE PAD WITH NEOPRENE GROMMET IF NON -SEISMIC RATED ISOLATOR USED <br />8 CONFIRM EQUIPMENT RPM, REFER TO "REQUIRED DEFLECTION BASED ON RPM" SPREADSHEET TO DETEREMINE PROPER DEFLECTION <br />9 THREE SPRING HANGERS FROM ROTATING EQUIPMENT CONNECTIONS <br />10 SEISMIC RESTRAINT AS REQUIRED BY CODE AND/OR LOCAL AUTHORITY HAVING JURISDICTION OR PER SMACNA GUIDELINES <br />* SUSPENDED EQUIP WITH IP=1.0 AND >20LBS REQUIRES SEISMIC BRACING - IF THE COMPONENT/EQUIPMENT IS RIGIDLY ATTACHED TO THE DUCT AND THE DUCT IS BRACED, THEN NO ADDITIONAL <br />SEISMIC IS REQ'D. COMPONENTS/EQUIP >75LBS REQUIRE INDEPENDENT VERTICAL SUPPORTS AND SEISMIC BRACING. EQUIP WITH IP=1.5 AND <20LBS AND FLEXIBLY CONNECTED MAY BE OMITTED <br />11 FLOOR STAND PROVIDED BY MECHANICAL CONTRACTOR <br />12 4" MINIMUM (CONFIRM WITH STRUCTURAL ENGINEER BASED ON EQUIPMENT WEIGHT AND EMBED ANCHOR DEPTH REQ'D) CONCRETE HOUSEKEEPING PAD INSTALLED UNDER UNIT BY GC <br />13 FOR UNITS THAT ARE GREATER THAN 2 HP IN SIZE <br />14 PROVIDE 1.5X'S UNIT WEIGHT IN CONCRETE BELOW UNIT AND MAXIMUM OF 1/8" DEFLECTION ACROSS LENGTH OF UNIT BY GC <br />15 DEFLECTION AS REQUIRED PER ASHRAE APPLICATIONS, CHAPTER 48 BASED ON STRUCTURE ITEM WILL BE SUPPORTED FROM (VERIFY PRIOR TO ORDER) <br />16 COMPONENT IMPORTANCE FACTOR (Ip = 1.5) <br />MINIMUM DUCT INSULATION LAST UPDATED 05/03/21 <br />INSULATION <br />DUCT SYSTEM <br />DUCT LOCATION AND USE <br />R-VALUE <br />REMARKS <br />CLIMATE ZONE 4C <br />SUPPLY AIR OR <br />OUTSIDE THE BUIDING (OUTDOORS AND EXPOSED TO WEATHER) <br />R-8 <br />1 <br />RETURN AIR <br />SUPPLY AIR OR <br />UNCONDITIONED SPACE (ENCLOSED BUT NOT IN THE BUILDING CONDITIONED <br />R-6 <br />1 <br />RETURN AIR <br />ENVELOPE <br />SUPPLY AIR OR <br />UNCONDITIONED SPACE (DUCT CONVEYS AIR THAT IS WITHIN 15-F OF THE AIR <br />RETURN AIR <br />TEMPERATURE OF THE SURROUNDING UNCONDITIONED SPACE) <br />R-3.3 <br />2 <br />SUPPLY AIR OR <br />IN A BUILDING ENVELOPE ASSEMBLY <br />R-16 <br />3 <br />RETURN AIR <br />WITHIN CONDITIONED SPACE (SUPPLY DUCT CONVEYS AIR THAT IS LESS THAN 55-F <br />R-3.3 <br />1 <br />SUPPLY AIR <br />OR GREATER THAN 105DF <br />SUPPLY AIR <br />WITHIN CONDITIONED SPACE THAT THE DUCT DIRECTLY SERVES SUPPLY DUCT <br />NONE <br />1 <br />WITHIN CONDITIONED SPACE (SUPPLY DUCT CONVEYS AIR THAT IS 55"F OR <br />SUPPLY AIR <br />GREATER AND 105DF OR LESS <br />NONE <br />- <br />RETURN OR <br />WITHIN CONDITIONED SPACE, DOWNSTREAM OF AN ENERGY RECOVERY MEDIA, <br />R-8 <br />- <br />EXHAUST AIR <br />UPSTREAM OF AN AUTOMATIC SHUT OFF DAMPER <br />RELIEF OR <br />WITHIN CONDITIONED SPACE AND DOWNSTREAM OF AN AUTOMATIC SHUT OFF <br />R-16 <br />- <br />EXHAUST AIR <br />DAMPER <br />OUTSIDE AIR <br />INSIDE CONDITIONED SPACE AND UPSTREAM OF AN AUTOMATIC <br />> 2800 CFM <br />R-16 <br />4 <br />SHUT OFF DAMPER <br />OUTSIDE AIR <br />INSIDE CONDITIONED SPACE AND DOWNSTREAM OF AN AUTOMATIC <br />> 2800 CFM <br />R-8 <br />SHUT OFF DAMPER TO HVAC UNIT OR ROOM <br />- <br />OUTSIDE AIR <br />INSIDE CONDITIONED SPACE <br /><2800 CFM <br />R-7 <br />5 <br />NOTES: <br />1 SEE ENERGY CODE SECTION 0403.10.1.2 FOR DETAILS <br />2 SEE IMC SECTION 603.12 FOR ADDITIONAL REQUIREMENTS FOR CONDENSATION CONTROL AT DUCTWORK <br />3 DUCT OR PLENUM IS SEPARATED FROM BUILDING ENVELOPE ASSEMBLY WITH THE MINIMUM INSULATION VALUE <br />4 SEE ENERGY CODE SECTION C403.10.1.1 FOR ADDITIONAL REQUIREMENTS <br />5 SEE EXCEPTION 1 TO SECTION C403.10.1.1 FOR ADDITIONAL DETAILS <br />STANDARD INSERT METHODS <br />EW AND EXISTING CONDITIO <br />DUCT CONSTRUCTION STANDARDSDUCTWORK HANGER REQUIREMENTS <br />ROUND, OVAL AND RECTANGULAR <br />RECTANGULAR DUCT <br />(w+D w1 ED^I <br />RECTANGULAR DUCT <br />Iw+D 5 1a0" a WIDTH GO') <br />SUPPORTS REQUIRED <br />SUPPORTS REQUIRED <br />. NO3 u : STUD (FLAT) <br />. M03 CABLE, BARREL (PAN) <br />. NO2 CRELE: STUD (FLAT) <br />• NO2 CABLE. BARREL (PAN) <br />BEARER REQUIRED <br />. O(UMUI TRAPEZE BRACKET <br />BEARER REQUIRED <br />. CRIPPLE TRAPEZE BRACKET <br />OVAL DUCT <br />Iww <_]0"Aw 6G"1 <br />OVAL DUCT <br />(W_5100"aw 6G-) <br />SUPPORTS REQUIRED <br />SUPPORTS REQUIRED_ <br />• NO3 CABLE: STUD (rLAT) <br />• MO) GABLE: BARREL .PAN) <br />• 102 CABLE: STUD (FLAT) <br />• NO3 CABLE: BARAEL (PAN) <br />BEARER REQUIRED <br />. MOGE, —UNL 1011' <br />BEARER REQUIRED <br />. P1000: 1-5.8" UNLBTRUT <br />HANGER SPACING GUIDE <br />INSTALL HANGERS SHOWN ON... <br />ROUND @ 1 EVERY 10 FEET <br />OVAL 0-1 EVERY 08 FEET <br />RECT V 1 EVERY 08 FEET <br />RECTANGULAR DUCT <br />(Ww 596•'AWIDTH 579') <br />SUPPORTS REQUIRED_ <br />• JIS GALV THREADED ROD - <br />BEARER REQUIRED <br />. P100E, 14 UNLSTRW <br />�. <br />OVAL DUCT <br />(W.D 5 98" A WIDTH 5 TB-) <br />SUPPORTS REQUIRED <br />• -GALV THREADED ROD <br />BEARER REQUIRED <br />. noaa 1dIB' uNl-B1RIR <br />RECTANGULAR DUCT <br />(w+D • t3G- a w1 X e 96-I <br />SUPPORTS REQUIRED <br />• Jr6 GALV THREADED ROD <br />BEARER REQUIRED <br />. P1001.. 1=EI8 DOUBLE STRUT <br />f i <br />OVAL DUCT <br />(W.D S 13G- a W TX 5 68-) <br />SUPPORTS REQUIRED <br />• JIS GALV THREADED ROD <br />BEARER REQUIRED <br />. P+ow.14Ue AGANLB BTIIUT <br />RECTANGULAR DUCT <br />Iw.D 5192Aw -9.,) <br />SUPPORTS REQUIRED <br />• 112 GALV THREADED ROD <br />BEARER REQUIRED <br />P1081: 1.518-DOUBLE STRUT <br />-------------- it <br />OVAL DUCT <br />IW+D<—L.w -96") <br />SUPPORTS REQUIRED <br />112 GALV THRIADID ROD <br />BEARER REQUIRED <br />. ► -111... DDU-. 511 UT <br />RECTANGULAR DUCT <br />IW.D 5192-AWIDTH 51—) <br />SUPPORTS REQUIRED <br />• 112 GALV THREADED ROD <br />BEARER REQUIRED <br />• J 114 STEEL ANGLE <br />r <br />OVAL UCT <br />IWD5 t92"aw D20") <br />SUPPORTS REQUIRED <br />12 GALV THREADED ROD <br />BEARER REQUIRED <br />. J.3.1r4 STEEL ANGLE <br />RECTANGULAR DUCT <br />I W.. 5 192" a WIDTHa4-I <br />SUPPORTS REQUIRED <br />• IM GALV THREADED ROD <br />BEARER REQUIRED <br />.4.4— STEEL ANGLE <br />OVAL DUCT <br />1W05152"aWIDTH 4a"I <br />SUPPORTS REQUIRED <br />• 112 GALV THREADED ROD <br />BEARER REQUIRED <br />4.4.114 STEEL ANGLE <br />6 6600 <br />ROUND DUCT ROUND DUCT ROUND DUCT ROUND DUCT ROUND DUCT <br />(DIAMETER 5I SO-) IDIAMETER< AB") IDIAMETER53S0") (DIAMETER <BAR-) IDIAMETER 5BAB')A ALL MB <br />SUPPORTS REQUIRED•• SUPPORTS REQUIRED•• SUPPORTS REQUIRED SUPPORTS REQUIRED SUPPORTS REQUIRED <br />• NO2 CARLE, MR (PLAT) ID RFT • H02 CABLE, STUD (PLAT) 15 FT . 31S GALV THREADED ROD 18 GALV THREADED ROD • LS GALV THREADED ROD <br />• NO3 CABLE, BARREL PAN 10 • NO2 CABLE BARREL PAN 15 PT <br />BEARER REQUIRED BEARER REQUIRED BEARER REQUIRED BEARER REQUIRED BEARER REQUIRED <br />• SIMGL! CABLE LOOP • SINGLE CANE LOOP .12 M BAND LOOP OR PEAR .12 GA BOTTOM SADDLE ONLY . 12 OA TOP AND BOTTOM EADDLC <br />11161ZESIN ARNA <br />Hermanson <br />Building Today, Defining Tomorrow <br />Hermanson Company LLP <br />1221 2nd Avenue North <br />Kent, Washington 98032 <br />Tel: (206) 575-9700 <br />Fax:(206) 575-9800 <br />www.hermanson.com <br />Contractor Reg I HERMACLO05BJ <br />RTU <br />REPLACE <br />EVERETT MALL PLAZA, SUITE C <br />1321 SE EVERETT MALL WAY <br />EVERETT, WA 98208 <br />SNgODOk <br />gc`00 F wnsyy�F.y,�2 <br />p� <br />61SIEi�� <br />�/ONAL 6 <br />DECEMBER 3, 2022 <br />ISSUE FOR PERMIT <br />Revisions <br />_ 12/02/22 JMH ISSUE FOR PERMIT <br />No. Date By Description <br />Design Team <br />Design JMH <br />Drawn FVP <br />Checked DTN <br />Pre -Construction Number 14-22-22759 <br />Construction Number <br />Issue Date <br />CONSTRUCTION <br />STANDARDS <br />- HVAC <br />