Laserfiche WebLink
E <br />• <br />W C I VAL <br />ARCHITECTURE + PLANNING + DESIGN <br />d. Emergency means -of -egress illumination should be provided per IBC Section 1008.3. The <br />construction drawings shall include a reflected ceiling plan indicating egress lighting. The <br />lighting shall specify a minimum 90-minute uninterrupted supply power per IBC Section <br />1008.3.4. <br />e. The exterior landings providing egress should be provided with emergency lighting. The <br />lighting shall specify a minimum 90-minute uninterrupted supply power per IBC Section <br />7008.3.4. See IBC Sections 1008.3.2 Item 5 and 1010. 7.6. <br />Response: Please see responses itemized by line below: <br />a. Noted. Please see updated permit drawings dated 8/26/2022, which include a full <br />architectural floor plan of the proposed A-2 space and an egress plan for the <br />proposed A-2 space. Refer to A2.1 for the updated floor plan and refer to T1.1 for <br />the updated egress plan. <br />b. Noted. Maximum Occupancy sign shall be located adjacent to Door 107A on the <br />plan West wall of the Lunchroom. Please see T1.4 and A2.2 in the updated permit <br />drawings dated 8/26/2022. <br />c. Noted. Please refer to the updated occupancy and egress plan on T1.1 for the <br />locations of tactile exit signs. Please refer to the RCP on A6.1 for locations and <br />specifications of over illuminated exit signs. <br />d. Noted. Existing emergency lighting system will be utilized to provide means -of - <br />egress illumination. Please refer to the RCP on A6.1 <br />e. Noted. Existing exterior site emergency lighting will be utilized at exterior landings. <br />Please refer to the RCP on A6.1. <br />Accessibility: <br />3. Additional accessibility requirements should be specified on Sheet. See IBC Section 7102.7, and <br />reference below to ICC A 117.1-09 unless noted otherwise. The following comments should be <br />addressed. <br />a. Show water closet centerline dimension measured from side wall per Section 604.2 <br />b. Show sink centerline dimension measured from the side wall per IBC Section 107.2.1 <br />c. Provide dimensions for the grab bars per Sections 604.5. 7 and 604.5.2, and Figures 604.5.1 <br />and 604.5.2. Require blocking to support a minimum 250 LB load. <br />d. Provide water closet seat height dimension per Section 604.4. <br />e. Provide a vertical grab bar on the sidewall per Figure 604.5.1 <br />f. Provide sink pipe insulation per Section 606.6 <br />g. Locate the water closet flush control on the open side per Section 604.6 <br />h. Provide signage per IBC section 1111.1. <br />• Response: Noted. Please see T1.4 Typical Accessible Mounting Heights and Code <br />Required Signage, and the updated A2.2 Interior Elevations for all requested dimensions <br />and diagrams. <br />6211 Roosevelt Way Northeast I Seattle, WA 98115 1206 522 3830 1 www.tca-inc.com �I <br />