Laserfiche WebLink
I <br /> 1 *** <br /> 2 38' St & Broadway Northbound and Southbound I <br /> 3 37th St & Broadway Northbound and Southbound <br /> 4 33' St & Broadway Northbound and Southbound <br /> 5 Pacific Ave & Broadway Northbound and Southbound I <br /> 6 Wall St & Broadway Northbound and Southbound <br /> 7 <br /> 8 *** <br /> 9 <br /> 10 The permanent thermal detection system shall be installed on the signal mast <br /> 11 arm on a 6' long camera mount bracket at a location directed by the Engineer, I <br /> 12 as close as practical to the end of the mast arm. The video detection cable shall <br /> 13 be installed in the mast arm per manufacturers recommendations. Any coiled <br /> 14 slack cable shall be mounted to the camera mount bracket at the back of the <br /> 15 pole. In the signal control cabinet, a video detection module shall be installed, <br /> 16 along with a surge protector and 4x6 fuse kit assembly. Video detection cable <br /> 17 hall be connectorized and all cables terminated to complete the system. City of <br /> 18 Everett signal technician will direct location of cable terminations, VIP module, I <br /> 19 and other hardware. Through the Engineer, the contractor shall contact Steve <br /> 20 Sawyer (425)328-0643 a minimum 3 days prior to activation to coordinate a <br /> 21 signal technician to be on site. I <br /> 22 <br /> 23 <br /> 24 8-20.3.GR8 <br /> 25 Construction Requirements <br /> 26 <br /> 27 8-20.3(14).GR8 <br /> 28 Signal Systems <br /> 29 <br /> 30 8-20.3(14),INSTI.GR8 <br /> 31 Section 8-20.3(14) is supplemented with the following: <br /> 32 <br /> 33 CNH 8-20.3(14)C INDUCTION LOOPS.DOCX <br /> 34 8-20.3(14)C Induction Loop Vehicle Detectors <br /> 35 <br /> 36 Section 8-20.3(14)C is supplemented with the following: <br /> 37 <br /> 38 (******) <br /> 39 Induction loops shall be constructed as detailed in City of Everett Drawing Nos. I <br /> 40 804, 805, 809, 810, and Section 8-20.3(14)C of the Standard Specifications with <br /> 41 the following modifications: <br /> 42 <br /> 43 1. The loop locations shall be marked on the pavement by the contractor <br /> 44 and approved by the engineer prior to sawcutting. At no point shall any <br /> 45 of the sawcuts pass closer than 2' to any utility cover. <br /> 46 2. Loop detector sealant shall be as shown in City of Everett Standard <br /> 47 Drawing 809, or as approved by the Engineer. <br /> 48 3. Rope is not required. <br /> 1 <br /> 2023 FEDERAL OVERLAY <br /> FEDERAL AID#STBGUL-2715(011) <br /> WO#3788 March 2,2023 SP-104 <br />