HM Pacific Northwest Inc. 5/18/2023
>
Contracts
>
Capital Contract
>
Capital Construction Contracts and Change Orders
>
HM Pacific Northwest Inc. 5/18/2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2023 10:08:21 AM
Creation date
5/19/2023 10:00:26 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
HM Pacific Northwest Inc.
Approval Date
5/18/2023
Council Approval Date
4/26/2023
Department
Public Works
Department Project Manager
Gina Loring
Subject / Project Title
2023 Federal Overlay
Public Works WO Number
PW3788
Tracking Number
0003683
Total Compensation
$1,553,777.40
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
318
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I I <br /> SEE STANDARD DRAWING 808 PAVED SHOULDER TRAVELLED WAY GENERAL NOTES FOR LOOP INSTALLATION: <br /> FOR JUNCTION BOX INSTALLATION <br /> OR SIDEWALK AREA SEE DETAIL A 1. INSTALL JUNCTION BOX AND LEAD-IN CONDUIT. <br /> SEE SPLICE DETAIL THIS SHEET 2. SAW LOOP SLOTS AND LEAD-IN SLOTS. <br /> THIS SHEET <br /> 3. LAY OUT LOOP WIRE BEGINNING ATJUNCTION BOX,ALLOWING 5'MINIMUM SLACK. <br /> _�`!—' 4. INSTALL WIRE IN LOOP SLOT.SEE LOOP WINDING DETAIL.1 <br /> SEE NOTE 11—� <br /> 7'*_ w 5. RETURN TO JUNCTION BOX AND IDENTIFY LEADS WITH PLAN DETECTOR NUMBER AND <br /> r",...: o PAVED SHOLDER s"FOR START AND"F"FOR FINISH. <br /> — —� 6. TWIST EACH PAIR OF LEAD-IN WIRES TWO TURNS SEE PLANS FOR LolizR S PER FOOT FROM LOOP TO JUNCTION <br /> BOX AND INSTALL IN LEAD-IN SLOT AND CONDUIT.REVERSE DIRECTION OF TWIST FOR <br /> CONDUITSIZE� h�i SEE DETAILAEACH SUCCESSIVE PAIR INSTALLED. <br /> ,,,._...„,,,,,,-..,.,- THIS SHEET 7. CONSTRUCT SUPPLEMENTAL SPLICE CONTAINING ANY SERIES OR PARALLEL LOOP <br /> CONNECTIONS REQUIRED IN PLANS.SUPPLEMENTAL SPLICES ARE SUBJECT TO THE <br /> SAME REQUIREMENTS SHOWN FOR THE LOOP LEAD AND SHIELDED CABLE SPLICE.IF <br /> 6"DEEP APPROVED BY ENGINEER SCOTCHLOK 3570 EPDXY KIT SEALING PACKS MAY BE <br /> SUBSTITUTED FOR THE SCOTCHCAST 82-B1 FOR SUPPLEMENTAL SPLICES. <br /> GRAVEL BASE SEE TABLE A <br /> FOR CONDUIT SIZE 8. SPLICE LOOP LEADS OR SUPPLEMENTAL SPLICE LEADS TO SHIELDED CABLE AS NOTED. <br /> 9. COMPLETE INSTALLATION AND TEST LOOP CIRCUITS OR COMBINATION LOOP CIRCUITS. <br /> JUNCTION BOX GURB &GUTTER SEE WSDOT STANDARD SPEC 8-20.3(14)D. <br /> 10. FOR LOOP LOCATION REFER TO STANDARD DRAWING 805 AND PLANS. <br /> TYPICAL CONDUIT PLACEMENT FOR LOOP LEAD-IN WIRES 11. SEAL ENDS OF CONDUIT WITH ELECTRICAL PUTTY OF SILICONE. <br /> 12. DRILL HOLE FOR HOME-RUN CONDUIT 1"LARGER THAN CONDUIT AND FILL VOID WITH <br /> HOT MIX ASPHALT. <br /> LOOP LEAD PAIRS 1-2 3 4-5 6-8 9-12 13. ALL SPLICES SHALL BE ABLE TO BE RAISED A MINIMUM OF 16"ABOVE GROUND LINE. <br /> CONDUIT SIZE(MIN) 2" 2" 2" (2)2" (2)2" 14. BUCHANAN 2006S SPLICE CAPS,CRIMP WITH BUCHANAN C-24 CRIMPER FOLLOWING <br /> TRENCH WIDTH(MIN) 4" 4" 4" 6" 6" MANUFACTURE'S INSTALLATION PROCEDURE.SOLDER CRIMP(NO OPEN FLAME TORCH <br /> NOTE:ALL STOP BAR LOCATIONS SHALL HAVE(2)2"CONDUIT SIZE MINIMUM OR SIMILAR IS ALLOWED)AND TAPE WITH 2 LAYERS OF TAPE. <br /> TABLE A ®INSTALLATION NOTES: <br /> 1. SEALANT-CRAFCO PART NO 34271,OR APPROVED EQUAL. <br /> 2. LOOP WIRE-NUMBER VARIES SEE LOOP WINDING DETAILS STANDARD DRAWING 810. <br /> DETECTOR LEAD-IN CABLE FOIL SHIELD 3. LEAD-IN WIRES:ONE PAIR FOR EACH LOOP SERVED,3 PAIR MAX PER SAWCUT. <br /> (IMSA 50-2-1984)OR 3 <br /> SHIELDED PAIR CABLE 4. EXTEND SAWCUT SUFFICIENT LENGTH TO PROVIDE FULL SAWCUT DEPTH AROUND <br /> < (BELDEN 1037A)AS NOTED 1 1/2 1" SEE NOTE 14 CORNERS. <br /> EDGE OF TRAVELLED WAY <br /> SEAL ENDS WITH OR CURB/GUTTER 5. LOCATE CORNER SAWCUT AT 45°TO SIDE CUTS TO PREVENT KINK IN LOOP WIRE AND <br /> f ELECTRICAL PUTTY A ALSO MINIMIZE VOID.TRIANGULAR VOID WILL BE REMOVED AND FILLED WITH <br /> o' AND TAPE ti 6" SEALANT. <br /> LOOP WIRE#14 <br /> *DRAIN WIRE �A A <br /> (IMSA51-7) <br /> n <br /> W -GROUND DRAIN WIRE AT SCOTCHAST EPDXY <br /> i AMPLIFIER ONLY 82-B1 SPLICE KIT SEE NOTE 12 <br /> °a FILLED WITH EPDXY SAWCUT(TYP) CITY OF EVERETT <br /> F S USE SAME PROCEDURE PAIR LEAD-IN PUBLIC WORKS DEPARTMENT <br /> - CABLE AND MULTIPLELE LOOPLOOP SPLICE <br /> `" SPLICE DETAIL DETAIL �' <br /> B'V vzisASS ICOvaiT I��rxmLHE. Ip—ESH <br /> 04/07/2017 <br /> MM.ONAWINO 16, <br /> TRAFFIC INDUCTION LOOP <br /> y JUNCTION BOX,SPLICE&NOTES 809 <br /> I <br /> - - - - - - - - - - - - - - - - - - - <br />