Laserfiche WebLink
MS Ell NM OM E NM EN EN MIN B MN NM NM NS <br /> I <br /> Q — NOTES: <br /> A JUNCTION BOX DIMENSIONS 1. ALL DIMENSIONS ARE MINIMUM.EXACT <br /> C — CONFIGURATIONS VARY AMONG DIFFERENT <br /> BOX TYPE MANUFACTURERS. <br /> MIME— o ITEM TYPE 1 TYPE 2 TYPE 8 <br /> 2. THE NOTED LID THICKNESSES ARE OVERALL <br /> A BOX OUTSIDE LENGTH 22" 33" 42" MINIMUMS.NON-SKID LID SHALL BE HOT DIP <br /> _____ 4 M B BOX OUTSIDE WIDTH 17" 22 1/2" 30" GALVANIZED IN ACCORDANCE W/ASTM A 123.AN <br /> APPROVED SURFACE PLATE IS STEEL"SLIPNOT GRADE <br /> R .: ;� C BOX INSIDE LENGTH 18" 28" 36" 3-COARSE"BY"W.S.MOLNAR CO". <br /> . ... D BOX INSIDE WIDTH <br /> z m o z ; ;% 13 17" 24 3. LID SUPPORT MEMBERS SHALL BE WELDED TO <br /> m ®�I ;.;. E LID LENGTH 17 7/8" 263/8" 377/8" FRAME. <br /> • ��•� F LID WIDTH 12 7/8" 16 7/8" 2S 7/8" <br /> _ 4. 4000 PSI CONCRETE IS ALLOWED IF BOX <br /> G BOX DEPTH 12" 12" 12 REINFORCEMENT CONSISTS OF 6x6-W3xW3 <br /> H LID THICKNESS 5/16" 5/16" 1/2" <br /> J WALL THICKNESS 11/2" 11/2" 3" WELDED WIRE FABRIC WELDED TO THE FRAME. <br /> K BOX OR EXTEN WALL WIRE REINF W-3 W-2.5 W-5 5. WHEN NOTED IN THE CONTRACT TYPE 2 AND TYPE 8 <br /> PLAN L LEGEND 1"xl"LTRS 1"xl"LTRS 1"xl' LTRS BOXES SHALL BE PROVIDED WITH 12"DEEP <br /> EXTENSION BOXES. <br /> _ LID HOOK Ll"xl"x3/16" M HANDLE N/A N/A ONE <br /> —1/16"CLR Q FOUNDATION OUTSIDE LENGTH 24-1/2" 35-1/2" 48" 6. WHEN NOTED IN THE CONTRACT TYPE 2 BOXES <br /> ii... ....,...,—.........,.., <br /> SHALL BE PROVIDED WITH A 10"x27 1/2"10 GAGE <br /> R FOUNDATION OUTSIDE WIDTH 19-1/2" 25" 36" DIVIDER PLATE COMPLETE WITH FASTENERS. <br /> S FOUNDATION INSIDE LENGTH 16-1/2" 27-1/2" 36" <br /> to C I T FOUNDATION INSIDE WIDTH 11-1/2" 17-1/2" 20" 7. NON CONCRETE BOXES MAY BE SUBMITTED FOR <br /> I APPROVAL 1/111111 K U FOUNDATION DEPTH 3" 3" 3" LOAD TEST. <br /> WILL INCLUDE AN H-20 <br /> V FOUNDATION REINF. N/A N/A 2-W-5 <br /> o MI W BOX EXTENSION DEPTH N/A N/A 12" 8. ALL BOXES WILL BE WSDOT APPROVED AND <br /> X FINGER HOLE#/DIA 2 @ 5/16" 2 @ 5/8" 1 @ 5/8" CERTIFIED. <br /> Q or R �� CAPACITY CONDUIT INCH 0'S 6 12 24 <br /> V 9. LEGEND FOR TRAFFIC SIGNAL SYSTEM BOXES WILL BE <br /> SECTION "TS",AND"LT"FOR ILLUMINATION SYSTEMS.LEGEND <br /> LETTERS WILL BE FORMED WITH 1/8"WELD BEAD. <br /> JUNCTION BOX <br /> JUNCTION BOX MATERIALS <br /> 8" <br /> •_❖.•.•.-....�:•..•..;' .•.. ITEM MATERIAL <br /> o ):40.•44+:4+:44e:;:;:;.;:;:;:;:;5*1:::;::; PAVED AREA Z BOX 6000 PSI CONC <br /> ••:• .• )t•:•:O° FRAME FLAT OR DIA-MOND GALV STEEL A786_ <br /> u •H -� •�****��•��� �;%�,�;�, UNPAVED LID SUPPORT 1/8"MIN GALV STEEL C,L OR T,-A36 <br /> i ❖.❖.❖.❖.❖.❖.❖.❖.❖.❖.❖.❖o.•.o•.000❖.•.000❖.❖.•.ov /------ z LID NON-SKID PLATE STEEL(GALV) <br /> PLANALV <br /> - tr3MAJ <br /> ANCHORS X \ �:---\\� <br /> B L,�, REINF ASTM A-82 STEEL <br /> 1/2"0 STEEL HANDLE iC oO HANDLE GALV STEEL <br /> Is' BASE SECTION FOUNDATION 3000 PSI CONC <br /> 2 2"MIN /_REQUIRED <br /> ,, ON ALL J-BOXES <br /> N . CITY OF EVERETT <br /> O <br /> „m HANDLE STOP NUT OR WELDED c - VL PUBLIC WORKS DEPARTMENT <br /> SECTION WASHER — _ <br /> p� '"�AAN SASS IEORE MT I` ZUMILHELM I""-IAK <br /> 01�172tl017 <br /> wo LID HANDLE FOR CONDUIT SIZE JUNCTION BOX INSTALLATION 6"DEEP "` W <br /> SEE PLAN SHEET GRAVEL BASE TRAFFIC JUNCTION BOX <br /> j,.o DETAILS 808 <br /> 1 1 <br />