My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3421 NASSAU ST 2023-05-19
>
Address Records
>
NASSAU ST
>
3421
>
3421 NASSAU ST 2023-05-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2023 1:30:24 PM
Creation date
5/19/2023 1:30:06 PM
Metadata
Fields
Template:
Address Document
Street Name
NASSAU ST
Street Number
3421
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I. <br /> 3414 <br /> SITE - <br /> PLAN FOUNDATION NOTES <br /> -- -;aan• <br /> PARCEL NO. —20,, PARCEL NO. 1. VERIFY ALL DIMENSIONS ON SITE. •oS,-•'•"La.•• <br /> 00437582701100 j \ 00437582701100 2. FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM WALL <br /> f 37'-0"• <br /> PER R&R LEVEL SURVEY. <br /> LEGAL DESCRIPTION 3. REFER TO THE FOLLOWING DETAILS FOR ADDITIONAL INFORMATION: ' <br /> T c HELICAL PILES 1/SD-1.1 •'X� "'-� , �- <br /> EVERETT DIV H PLAT OF y -0.. <br /> BLK 827 D-00-LOTS 11 & aoa• eon• 4. REFER TO STRUCTURAL CALCULATIONS PACKAGE DATED SEPTEMBER 1,2022, <br /> 12 cc FOR ADDITIONAL INFORMATION,SPECIFICATIONS,AND REQUIREMENTS. <br /> 4 i 5. LEVEL SURVEY PER R&R REPAIR PLAN DATED MAY 25,2022 REFER TO <br /> OWNER NAME& STRUCTURAL CALCULATIONS PACKAGE FOR MODIFICATIONS AND ADDITIONAL <br /> DECK ADDRESSINNER6.R MINIMUM L FORIREPAIRERPLAN. <br /> 9 SKINNER JACOB 6. MINIMUM PILE DIAMETER SHALL BE 2-7/8'.HELIX CONFIGURATIONS PER R&R TO <br /> 3421 Nassau St,Everett, WA MEET LISTED DESIGN STRENGTH WITH APPLICABLE FACTORS OF SAFETY. <br /> / AREA OF 98201 7. IT IS ACCEPTABLE TO INSTALL PILES AT THE SPACING SHOWN WITH±0'-6" <br /> WORK /-11-0"• / TOLERANCE TO ALLOW FOR UNEXPECTED OBSTRUCTIONS ENCOUNTERED <br /> POWER�� DURING PILE INSTALLATION PROVIDED THAT NO TWO ADJACENT SPANS EXCEED <br /> y\ THE SPACING LIMITATION OF 8'-0"0.C.MAXIMUM. <br /> N <br /> 8. ALL SUPPLEMENTAL CHANNELS TO SPAN FROM PILE TO PILE AND EXTEND MIN W <br /> LOT SIZE 6"PAST SUPPORTING PILE EA END. Q - <br /> \\I. 0.18(7,841SQFT) OVERALL PARCEL PLAN 9. ALL SUPPLEMENTAL CHANNELS TO BE ANCHORED TO THE FOUNDATION WITH w <br /> 12)PLES�B-0.O.C.MAX 5/8'DIAM.x 4"SIMPSON TITEN HD SCREW ANCHORS(OR APPROVED EQUIVALENT) D Z O <br /> 2,-0"•c N.T.S. AT A MAXIMUM SPACING 1 B"OC.ANCHORS TO BE CENTERED ON OR INSTALLED W <br /> i 3 x 2 o BUILDING LOT ABOVE THE CENTER LINE OF THE CHANNEL. FS Z <br /> /�T COVERAGE W <br /> \ 10.FIELD VERIFY ALL EXISTING STEM WALLS AT AND BETWEEN PILE ATTACHMENT <br /> P 27%(1,952 SQFT) LOCATIONS ARE 8"THICK MINIMUM WITH 2'-8"HEIGHT(MEASURED FROM B/FTG TO z W Z <br /> ( <br /> LOCATE ILE 3•-0-O.C. T/GONG)MINIMUM.FIELD VERIFY EXISTING CONCRETE SLAB-ON-GRADE AT PILE O '. <br /> MAX FROvt CORNER IMPERVIOUS ATTACHMENT IS 4"THICK MINIMUM. 0 <br /> �1y1 COVERAGE SITE PLAN LEGEND J <br /> LOCATE MAxROM CORNER` T o 11.PARCEL DIMENSIONS PROVIDED BY CITY OF SEATTLE.NOT TO SCALE. <br /> -35/O(2,714 SOFT) PROPERTY LINE AND RESIDENCE LOCATING DIMENSIONS(WITH ASTERISK,•) <br /> LiEXISTING RESIDENCE STRUCTURE APPROXIMATED PER SNOHOMISH COUNTY!MAP AND SEATTLE DEPARTMENT OF <br /> o CONSTRUCTION AND INSPECTIONS GIS MAPPING TOOLS.NOT TO BE USED FOR <br /> N LEGAL PURPOSES. <br /> EXISTING ADJACENT STRUCTURE 12.SITE FEATURES AND EXISTING STRUCTURES ON ADJACENT PARCELS NOT )41 <br /> •(E)RESIDENCE ----.---__....- — -- L---- — <br /> 3421 Nassau St, -----------' -- _--__ SHOWN FOR CLARITY. <br /> Everett,WA 982011 N ' AREA OF PROPOSED WORK 14.PILES SHALL BE INSTALLED TO A MINIMUM EMBEDMENT OF 5'-0"OR UNTIL <br /> (El 6'CONCRETE STEM REFUSAL,WHICHEVER IS SHALLOWER. <br /> WALL TALL MIN TYP AT <br /> PERIMETER * PROPERTY LINE <br /> NOTIFY LIED PRIOR TO HELICAL PILE REFUSAL CRITERIA: <br /> WORN IF CONCRETE WALL <br /> AT PILE LOCATORS IS TORQUING OF THE PILE SHALL CONTINUE UNTIL A HYDRAULIC PRESSURE IS <br /> LESS THAN r.o•rAu APPROXIMATE DIMENSION ACHIEVED TO PROVIDE THE SPECIFIED MINIMUM VERTICAL CAPACITY WITH A <br /> SAFETY FACTOR OF NO LESS THAN TWO.ADVANCEMENT SHALL BE HALTED <br /> IMMEDIATELY IF THE STRUCTURE BEGINS TO EXPERIENCE UPLIFT FLEXURE. <br /> J _ ¢# HELICAL PILE - <br /> \ ® EXISTING POST <br /> A <br /> LU o <br /> Sc GASH Z o <br /> FRONT M ty 3421 Nassau St, <br /> PORCH E i- ELEVATION MAP Everett,WA 98201 <br /> w <br /> /-4'-0"•—" 16'-0"' - / 20'-0"• <br /> S220712-3XR <br /> — NJ <br /> Decking <br /> MRT <br /> Power (2)PI ILES O.6'-0"O.C.MAX <br /> DRIVEWAY TO 3 I I 9/1/22 <br /> LOCATE PILE 3'-0"O.C. <br /> ACCESS 3Access_? MAX FROM CORNER <br /> ---'-- - ---._. —._s.- '1.�a .1 .a'. <br /> -14) -Ire -12 OCATE PIL.3'-0"OC. >I <br /> 1/4"= 11-0" <br /> FROM CORNER 77 <br /> 2 1 <br /> ___.-._- ---_.. - _.._-11%4 x =3"Helical Pile <br /> PC=Remove and Replace Post <br /> PILE SPACING&LOAD REQUIRMENTS TABLE * , <br /> .,re <br /> MAX O.C.SPACING,ft MIN VERTICAL CAPACITY,kips PROOF TESTING LOAD,kips ° <br /> PILE# PILE TYPE BTWN END 200%MIN VERTICAL CAPACITY(MIN LOCATION y <br /> PILES OFFSET ALLOWABLE LOADING ULTIMATE CAPACITY) '� -148 <br /> 1 HELICAL 6'-0"UNO 3-0'UNO 9 0 kip 19 0 kip TYP <br /> Xir <br /> #2-3 HELICAL 6'-0"UNO 3'-0"UNO 11 0 kip 22 0 kip TYP <br /> NOTES: <br /> a. MINIMUM AND MAXIMUM INSTALLATION TORQUE FOR HELICAL ASSEMBLIES SHALL BE SPECIFIED BY THE PILE MANUFACTURER.THE MINIMUM INSTALLATION <br /> TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING CAPACITY LOADING.INCLUDING A SAFETY FACTOR NO LESS THAN 2.THE MAXIMUM <br /> INSTALLATION TORQUE SHALL NOT EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF THE PILE ASSEMBLY.MAXIMUM R&R p <br /> INSTALLATION TORQUE RATING OF 8,300FT <br /> LB• S FOR 2-718 INCH DIAMETER HELICAL PILE WITH 0.203 INCH SHAFT WALL THICKNESS PER ESR-3750. LEVEL SURVEY <br /> b. HELICAL ASSEMBLIES AS MANUFACTURED BY IDEAL MANUFACTURING,INC.,IN ACCORDANCE WITH ESR-3750. <br /> C.PILE OR ANCHOR LOADS NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART OF THE ASSEMBLY. SEE STRUCTURAL CALCULATION PACKAGE FOR ADDITIONAL REQUIREMENTS <br /> d. MAXIMUM ON-CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN. <br /> NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. FOUNDATION PLAN a <br /> w <br /> I- <br /> 3�4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.