Laserfiche WebLink
' aofa <br /> (E)WOOD FRAMED '. e ,,?:: <br /> FLOOR SYSTEM, ; ki <br /> FIELD VERIFY <br /> w• <br /> G. <br /> (E)CONC STEM WALL <br /> T/STEM WALL= <br /> ° FIELD VERIFY <br /> 8"MIN THICKNESS, T/FIN GRADE_ <br /> CONTRACTOR TO VERIFY ° ' VARIES <br /> =cc 1 (E)FTG TO BE CUT FLUSH <br /> Ei oLL <br /> _ WITH FACE OF STEM WALL <br /> q§jj WITH A 12"MAX WIDTH FOR W <br /> z o INSTALLATION POCKET Q ° z <br /> NOS E. Z,o <br /> _ TICONC FTG= I— W m <br /> = FIELD VERIFY / z <br /> <Jw <br /> zwz <br /> Zz <br /> (E)CONTINUOUS �' <br /> CONC FOOTING IDEAL HELICAL PILE&REPAIR <br /> BRACKET ASSEMBLY PER <br /> NOTES: R&R FOUNDATION SPECIALIST <br /> 1.CONTRACTOR TO VERIFY NOTED MINIMUM EXISTING FOUNDATION TO CONFORM TO ESR-3750 �/ ' <br /> DIMENSIONS PRIOR TO INSTALLATION.ENGINEER-OF-RECORD TO BE 2-7/8"SHAFT W/10"DIAM <br /> NOTIFIED PRIOR TO INSTALLATION IF MINIMUMS NOT MET. DOUBLE HELIX W/3 PITCH ..0� <br /> 2.ALL ASSEMBLY COMPONENTS SHALL BE FULLY SEALED BY A <br /> CORROSION RESISTANT SYSTEM.THIS INCLUDES ALL FINAL CUT <br /> ENDS AND DRILLED HOLES.CORROSION PREVENTION COATING <br /> SYSTEM BY OTHERS.PRIME AND PAINT PER MFR OR GALVANIZATION <br /> PER ASTM 153/A123. <br /> 3.AT CUT INSTALLATION POCKET ALL EXPOSED STEEL <br /> REINFORCEMENT SHALL BE SEALED OR COATED TO PREVENT - --- <br /> CORROSION. - " <br /> 1 HELICAL PILE INSTALLATION DETAIL 2 NOT USED 3 NOT USED <br /> 3421 Nassau St, <br /> Everett,WA 98201 <br /> S220712-3XR <br /> NJ <br /> MRT <br /> - - = 9/1/22 <br /> J_ <br /> h <br /> W <br /> 0 <br /> Z ,--1 <br /> O <br /> ., ri <br /> Q 6 <br /> 0 N <br /> z <br /> 4 NOT USED 5 NOT USED 6 NOT USED o J <br />