Laserfiche WebLink
0 , <br /> 3. Thank <br /> ble youto for providingil a scalePlease on thedraw sitethe plansite pl. Howevertomore,the 1'=typical23'scalescale is(for not a scaleexample that <br /> 1" I i <br /> am a easy measure. an a , _ <br /> 20'). <br /> The Site Plan has been scaled to 1"=20'. <br /> 4. The dimensions called out on the site plan do not add up to the 120' lot depth. For example, <br /> 10+36+33(28')+39+7= 125'. Please revise accordingly. <br /> Note:the issue may be the gap between the 34' dimension and the 33' dimension. <br /> You are correct the error is the gap. This distance previously noted as 33' has been correctly <br /> shown as 28' and adjusted. <br /> 5. The site plan indicates the front of the house is flat/straight across and does not show the bump <br /> out/one-story portion on the south side of the front facade(see picture below). Please revise <br /> the site plan accordingly. <br /> The bump out is 2 1/2' in width and 27' in length and has been added/shown on the Residential <br /> Site Plan. <br /> 6. Please provide all exterior building dimensions of the ADU, like you provided for the main <br /> residence. For example,the exterior dimensions on the west side of the structure were not <br /> provided(see attached residential construction checklist for site plan example). <br /> All exterior building dimension of the ADU have been added to the Residential Site Plan. <br /> 7. Thank you for showing the covered deck/awning structure attached to the back of the house on <br /> the site plan. However,dimensions of this covered area were not provided. Please add to the <br /> site plan. <br /> N/A as you noted in subsequent email;the covered area has been removed. <br /> 8. Thank you for revising the pitch of the roof to 6:12 so the structure complies with the 2 <br /> floors/24'height limit. You indicate in your response letter that the site plan has been updated <br /> to include the average alley elevation at the rear lot line that was field verified. However, I do <br /> not see this information on the site plan. The average alley elevation must also be shown on <br /> the elevation drawings. Please provide the overall height of the structure measured from the <br /> average alley elevation. <br /> Note: There is an example on the bottom of page 5 of what height dimensions to show on the <br /> elevation drawings of the structure. <br /> Please see attached Building Plans that had been previously submitted to the Building Dept. and <br /> the height survey. This information has been added to the Residential Site Plan.The building <br /> height from the base elevation as shown on the plan is 23' 10.5". <br /> 9. The proposed height is 23' 10.5". The height limit is 24'. Since the proposed height is within 1- <br /> foot of the 24' height limit,a height survey is required from a professional land surveyor. Please <br /> submit the"base elevation survey"form on page 6 of the attached document. The"height <br />