My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6522 WETMORE AVE 2023-05-31
>
Address Records
>
WETMORE AVE
>
6522
>
6522 WETMORE AVE 2023-05-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/31/2023 1:16:29 PM
Creation date
5/31/2023 1:15:45 PM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
6522
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and <br /> ACCA Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to <br /> determine cooling loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U- <br /> factor of 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each <br /> section,some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy <br /> Extension Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> MAVERICK ADDITION SIALER DESIGN LLC <br /> 6522 WETMORE AVE SE 16008 MOTOR PL <br /> EVERETT,WA 98203 LYNNWOOD,WA 98087 <br /> Heating System Type: All Other Systems 0 Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> Instructions Design Temperature Difference(AT) 49 <br /> Everett Paine AFB AT=Indoor(70deg-ees)-Outdoor DesiyiTemp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 587 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 7.3 4,257 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions <br /> 0.30 101 30.39 <br /> Skylights U-Factor X Area = UA <br /> Instructions 0.50 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions •r R-49 E 0.026 587 15.26 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> Instructions Select R-Value 0 No selection -- <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions 0.056 424 23.76 <br /> R-21 Intermediate <br /> Floors U-Factor X Area UA <br /> Instructions R-30 �� 0.029 587 17.02 <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions No selection <br /> Select R-value <br /> Slab Below Grade(see Figure 1) F-Factor X Len th UA <br /> Instructions No Slab Below Grade in the <br /> Slab on Grade(see Figure 1) F-Factor X Length UA <br /> Instructions No Slab on Grade in this ppii <br /> Location of Ducts <br /> Instructions Duct Leakage Coefficient <br /> Unconditioned S•ace 1.10 <br /> Sum of UA 86.44 <br /> Envelope Heat Load 4,235 Btu/Hour <br /> Figure 1. SurnotUAXAT <br /> Air Leakage Heat Load 2,253 Btu/Hour <br /> Volume 0.6XATX.018 <br /> Above Building Design Heat Load 6,488 Btu/Hour <br /> Air Leakage+Envelope Heat Loss <br /> Building and Duct Heat Load 7,137 Btu/Hour <br /> Grade <br /> Ducts in uicondtioned space:$un cf Bullring Heat Loss X 1.10 <br /> Ducts in coreiticned space:Sun o Budding Heat Loss X 1 <br /> Maximum Heat Equipment Output 9,992 Btu I Hour <br /> &ilding and Duct Heat Loss X 1.40 kr Forced Air Funace <br /> Balding and Duct Heat Lass X 1.25 kr Heat Pimp <br /> (07/01/13) <br />
The URL can be used to link to this page
Your browser does not support the video tag.