My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3322 52ND PL SW 2023-05-31
>
Address Records
>
52ND PL SW
>
3322
>
3322 52ND PL SW 2023-05-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/31/2023 1:25:02 PM
Creation date
5/31/2023 1:24:42 PM
Metadata
Fields
Template:
Address Document
Street Name
52ND PL SW
Street Number
3322
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E O ET SEC <br /> SECONDRESPONS INTAKETOCITY BUILDING FVERET <br /> REVIEW PERMIT RESPONSERVI ES <br /> 1 <br /> Permit*: B2106-014 1 <br /> Project: Coon's Basement + ADU SEP z <br /> ECE112V021Et.' <br /> 3322 52nd Place Southwest I Everett, WA 98203 CITY OF EVERET <br /> Permit Services <br /> Owners: Leroy and Su- <br /> Hong Coons <br /> Applicants: Nancy Goodin 1206.304.2120 <br /> Doug Ward 1206.790.8039 <br /> Raeward Construction LLC <br /> Email: raewardconstructionllc@gmail.com <br /> Reviewer: Drew Martin, P.E., S.E. 1425.257.8813 <br /> City of Everett Permit Services <br /> 3200 Cedar Street, 2nd Floor I Everett, WA 98201 <br /> Date: September 20, 2021 <br /> Hello Drew, <br /> Thank you for reviewing our project and also taking the time to discuss this project with me last <br /> week. The drawings have been revised per your comments and below are our written <br /> responses: <br /> 1. COMMENT: The Building Code information on Sheet A-1.0 lists the IBC as the governing <br /> code. It is presumed that the IRC is intended; comments have been provided <br /> accordingly. If the IBC is intended, additional requirements may apply, such as installing <br /> a sprinkler system. <br /> RESPONSE: Your presumption is correct and the drawings have been updated to show <br /> the current residential codes on Sheet Al to include the 2018 IRC, WSEC and EMC. <br /> 2. COMMENT: Continuing with the previous comment, the building data on Sheet A-1.0 <br /> should be updated to be consistent with the IBC. For example, the Construction Type <br /> does not apply to IRC construction. <br /> RESPONSE: The building data has been updated on Sheet Al. <br /> 3. COMMENT: The project involves adding an ADU in the basement of the existing two- <br /> story house. This will require the entire house to comply with the requirements of IRC <br /> Section R314 and R315 for smoke and CO alarms. Plans for all levels of the house are <br /> required. The levels not included in the current project need only show the overall <br /> layouts of each level, window and door locations, alarm locations, and use of each <br /> room. Egress components such as hallways and stairs should also be shown. <br /> 0.0f 4 I <br />
The URL can be used to link to this page
Your browser does not support the video tag.