Lateral System: <br /> 6.The project includes a two-hour fire wall per the First Floor Plan on Sheet A2.03. The north and <br /> south shear walls are continuous through the fire wall; the walls should be discontinuous. The <br /> shear wall design should be revised. Additional holdowns should be provided at each end of <br /> each wall segment. Calculations substantiating the revised design should be submitted for <br /> review. See IBC Sections 706.2, 1604.1, 1604.4, 1613.1, and 2306.1, and AWC SDPWS-15 <br /> Section 4.3.6.4.2. <br /> RE: PLEASE SEE MODIFIED 2/S-1. PLEASE SEE ATTACHED CALCULATIONS PAGE 1 TO 5 FOR <br /> REVISED SHEARWALL CALCULATIONS FOR WIND AND SEISMIC. <br /> 7. Sheet S-2 indicates that the prefabricated roof trusses will align with the east and west shear <br /> walls below. The trusses appear to provide the horizontal load path between the roof <br /> diaphragm and walls. Design criteria for the trusses should be included in Roof Plan 1/S-2. A <br /> detail should be provided in the drawings showing the required connections between the <br /> trusses, roof diaphragm, and shear wall. Alternatively, the shear wall sheathing should extend <br /> to the roof diaphragm. See IBC Sections 107.2.1, 1603.1.8, and 1604.4. <br /> RE: SEE DETAIL 3/S-2 WHERE THE SHEARWALL SHEATHING HAS BEEN EXTENDED UP AND <br /> CONNECTED TO THE ROOF DIAPHRAGMS <br /> 8.The shear wall holdown design is provided on pages 10 and 11 of the structural calculations. <br /> The earthquake component of the uplift forces exceeds 20% of the total uplift(i.e., the <br /> earthquake force is 100% of uplift force). The earthquake component shall be increased per <br /> the provisions of ACI 318-14 Section 17.2.3.4.3. In addition, the anchorage utilizies post- <br /> installed anchors and shall satisfy the provisions of Section 17.2.3.3. Revised calculations <br /> substantiating the holdown design shall be submitted for review. The design load shall be <br /> determined per ASCE 7-10 Section 12.4.3.2 Equation 7 including the vertical seismic load effect <br /> per Section 12.4.2.2. The seismic holdown forces shall be calculated even when wind controls <br /> the lateral design. See IBC Sections 1604.10, 1613.1, and 1901.2. <br /> RE: SEE ADDITIONAL CALCULATIONS ON PAGE 7 TO 13 FOR EPDXY ANCHOR CALCULATIONS, AND <br /> UPDATED DETAIL 3/S-3 <br /> 9.The project infills two separate buildings, effectively creating one structure. The infill should be <br /> designed to have connective capacity complying with ASCE 7-10 Section 12.1.3. Details for <br /> connections to the new and existing roof sections should be provided in the construction <br /> drawings. The roofs should be provided with subdiaphragms to develop the connection loads <br /> into the roof diaphragms. Calculations substantiated the connections and subdiaphragms <br /> should be submitted for review. See IBC Section 1604.1, 1604.4, and 1613.1. <br /> RE: PLEASE SEE ADDITIONAL CALCULATIONS PAGE 14 AND REVISED DETAIL 3/S-3 <br /> Miscellaneous: <br /> 10. Detail 6/S-2 shows the typical header framing. The detail should be revised to provide <br /> connections between the header and supported framing. The connections should be adequate <br /> to comply with both IBC Section 1607.14 and ASCE 7-10 Section 12.1.4. See IBC Section <br /> 1613.1. <br /> RE: PLEASE SEE UPDATED DETAIL 6/S-2. PLEASE NOTE FOR CONNECTION HAS BEEN ADDED TO <br /> THE DETAIL. <br />
The URL can be used to link to this page
Your browser does not support the video tag.