Laserfiche WebLink
M EC HAMCAE HVAC LEGEND <br />LEGEND <br />GENERAL <br />SYMBOL <br />DESCRIPTION <br />24 12 <br />RECTANGULAR DUCT, FIRST NUMBER <br />24 12 <br />INDICATES SIZE FOR SIDE SHOWN <br />24/ <br />DUCT SHOWN IN SECTION, ARROW <br />POINTS TO SIDE CALLED OUT FIRST <br />244 <br />ROUND DUCT, NUMBER INDICATES <br />240 <br />DIAMETER <br />24/12 <br />OVAL DUCT, FIRST NUMBER INDICATES <br />24 12 <br />MAJOR DIAMETER, SECOND NUMBER <br />INDICATES MINOR DIAMETER <br />SUPPLY AIR DUCT, SQUARE OR <br />RECTANGULAR ELBOW FACING TOWARDS <br />i <br />SUPPLY AIR DUCT, SQUARE OR <br />RECTANGULAR ELBOW FACING AWAY <br />EXHAUST, RETURN OR SUPPLY AIR DUCT <br />ROUND, ELBOW FACING TOWARDS <br />--- <br />EXHAUST, RETURN OR SUPPLY AIR DUCT <br />ROUND, ELBOW FACING AWAY <br />EXHAUST AIR RETURN AIR DUCT, <br />SQUARE OR RECTANGULAR, <br />TANGULAR, ELBOW <br />FACING TOWARDS <br />EXHAUST AIR OR RETURN AIR DUCT, <br />I <br />SQUARE OR RECTANGULAR, ELBOW <br />FACING AWAY <br />TRANSITION RECTANGULAR TO <br />"—I <br />RECTANGULAR <br />TRANSITION AT TAKE OFF <br />TRANSITION SQUARE OR RECTANGULAR <br />_ _ _ <br />TO ROUND OR OVAL <br />UP <br />JUWN <br />DUCT OFFSET UP OR DOWN <br />OPPOSED BLADE DAMPER <br />i <br />PARALLEL BLADE DAMPER <br />VOLUME DAMPER <br />DUCT DAMPER, MOTOR OPERATED <br />(ELECTRIC OR PNEUMATIC) <br />r�IBACK <br />DRAFT DAMPER (ALLOWS <br />BD <br />FLOW IN DIRECTION OF ARROW) <br />AD OR AP <br />ACCESS DOOR (AD) OR <br />0 <br />ACCESS PANEL (AP) <br />FD <br />rE <br />FIRE DAMPER (1 HOUR) <br />FD2 <br />FIRE DAMPER (2 HOUR) <br />GENERAL <br />SYMBOL <br />DESCRIPTION <br />1 <br />RECTANGULAR DUCT, SQUARE ELBOW <br />WITH TURNING VANES <br />RECTANGULAR DUCT, RADIUS VANED ELBOW <br />EXTRACTION GRID <br />FM------bW <br />FLEXIBLE DUCT <br />FLEXIBLE DUCT CONNECTION <br />SIDEWALL SUPPLY AIR DIFFUSER, <br />100 CFM <br />GRILLE OR REGISTER AND CFM <br />AIR FLOW <br />SIDEWALL RETURN/EXHAUST AIR GRILLE <br />100 FM <br />OR REGISTER AND AIR FLOW <br />�111 0 FM <br />SCREENED OPENING AND CFM AIR FLOW <br />SUPPLY OUTLET, CEILING TYPE, <br />1400 CF <br />DIFFUSER OR GRILLE, SQUARE OR <br />LJ <br />RECTANGULAR AND CFM AIR FLOW (4 TY <br />I I <br />SUPPLY OUTLET, CEILING TYPE, ROUND <br />AND CFM AIR FLOW (SEE NOTE 4) <br />400 CFN <br />LINEAR DIFFUSER AND CFM AIR FLOW <br />100 <br />(SEE NOTE 4) <br />74r <br />RETURN/EXHAUST REGISTER OR GRILLE, <br />�J 100 CF <br />CEILING DUCT TYPE AND CFM AIR FLOW <br />RETURN/RELIEF GRILLE, CEILING TYPE, <br />NON —DUCTED <br />fUNIT <br />HEATER, HORIZONTAL <br />ROB <br />UNIT HEATER, VERTICAL PROJECTION <br />LINED DUCT <br />SOUND ATTENUATOR <br />0 i <br />LINED DUCT WITH ACCESS DOOR <br />AND SMOKE DAMPER <br />LINED DUCT WITH AXIAL FLOW FAN <br />CENTRIFUGAL FAN <br />CENTRIFUGAL FAN, INLET GUIDE VANES <br />F—LD <br />Fo <br />EXHAUST FAN <br />SUPPLY AIR FLOW DIRECTION <br />RETURN, OUTSIDE OR EXHAUST AIR <br />FLOW DIRECTION <br />GENERAL <br />SYMBOL <br />DESCRIPTION <br />® <br />THERMOSTAT, REMOTE, CEILING <br />Q <br />HUMIDISTAT, WALL <br />❑H <br />HUMIDISTAT CEILING <br />4 D <br />DUCT TYPE SMOKE DETECTOR <br />E D <br />DUCT TYPE HEAT DETECTOR <br />STATIC PRESSURE REGULATOR <br />TEMPERATURE SENSOR, HUMIDITY <br />SENSOR, DUCT MOUNTED <br />0 <br />THERMOSTAT, WALL <br />ON <br />NIGHT THERMOSTAT <br />m <br />THERMOSTAT, CEILING <br />Q <br />TEMPERATURE TRANSMITTER <br />VAV TERMINAL LEGEND <br />1ST AND 2ND CHARACTER: <br />UNIT SIZE <br />3RD CHARACTER: <br />WC=HOT WATER COIL <br />AC UNIT SERVED FROM <br />*TERMINALMARK NUMBER <br />SUGGESTED ABBREVIATIONS <br />SUGGESTED ABBREVIATIONS <br />ABBREVIATION DESCRIPTION I I ABBREVIATION DESCRIPTION <br />A <br />ANCHOR <br />AAV <br />AUTOMATIC AIR VENT <br />AD <br />ACCESS DOOR <br />ADD <br />ANGULAR DOWN DISCHARGE <br />AF <br />AIR FOIL WHEEL <br />AFF <br />ABOVE FINISHED FLOOR <br />AP <br />ACCESS PANEL <br />APPROX <br />APPROXIMATELY <br />ARCH <br />ARCHITECTURAL <br />AUD <br />ANGULAR UP DISCHARGE <br />AVG <br />AVERAGE <br />BI <br />BACKWARD INCLINED WHEEL <br />BDD <br />BACK DRAFT DAMPER <br />BFP <br />BACKFLOW PREVENTER <br />BHD <br />BOTTOM HORIZONTAL DISCHARGE <br />BHP <br />BRAKE HORSE POWER <br />BLDG <br />BUILDING <br />BOD <br />BOTTOM OF DUCT <br />BOP <br />BOTTOM OF PIPE <br />BOS <br />BOTTOM OF STEEL <br />BTU <br />BRITISH THERMAL UNIT <br />BTUH <br />BRITISH THERMAL UNIT PER HOUR <br />BW <br />BUTTWELD <br />C <br />COMMON <br />Cv <br />FLOW COEFFICIENT <br />'C <br />TEMPERATURE — DEGREES CELSIUS <br />CAP <br />CAPACITY <br />CC <br />COOLING COIL <br />CCW <br />COUNTER CLOCKWISE ROTATION <br />CFM <br />CUBIC FEET PER MINUTE <br />CI <br />CAST IRON <br />q <br />CENTER LINE <br />CONN <br />CONNECTION <br />CONT <br />CONTINUED/CONTINUATION <br />CPLG <br />COUPLING <br />CW <br />CLOCKWISE ROTATION <br />DA <br />DIRECT ACTING <br />DB <br />DRY BULB TEMPERATURE <br />DBD <br />DOWN BLAST DISCHARGE <br />DIA 0 <br />DIAMETER <br />DIS <br />DEIONIZED WATER SUPPLY <br />DIR <br />DEIONIZED WATER RETURN <br />DN <br />DOWN <br />DS <br />DOWNSPOUT <br />DWG <br />DRAWING <br />dB <br />DECIBELS <br />EA <br />EXHAUST AIR / EACH <br />EAT <br />ENTER AIR TEMPERATURE (F) <br />EFF <br />EFFICIENCY <br />ELL <br />ELBOW <br />ELEC <br />ELECTRICAL <br />ELEV, EL <br />ELEVATION <br />ESP <br />EXTERNAL STATIC PRESSURE <br />EVAP <br />EVAPORATOR <br />EWT <br />ENTERING WATER TEMPERATURE <br />EXH <br />EXHAUST <br />EXIST <br />EXISTING <br />EXT <br />EXTERIOR / EXTERNAL <br />'F <br />TEMPERATURE — DEGREES FAHRENHEIT <br />FC <br />FORWARD CURVE WHEEL <br />FD <br />FIRE DAMPER <br />FLR <br />FLOOR <br />FCO <br />FLOOR CLEAN OUT <br />FOB <br />FLAT ON BOTTOM <br />FOF <br />FACE OF FLANGE <br />FOIC <br />FURNISHED BY OWNER, INSTALLED BY CONTRACTOR <br />FOT <br />FLAT ON TOP <br />FPM <br />FEET PER MINUTE <br />FS <br />FLOW SWITCH <br />FT <br />FEET <br />FV <br />FACE VELOCITY FPM <br />GAL <br />GALLONS <br />GPM <br />GALLONS PER MINUTE <br />GALV <br />GALVANIZED <br />GA <br />GAGE, GAUGE <br />HC <br />HEATING COIL <br />HD <br />HEAD — FEET OF WATER <br />HORIZ <br />HORIZONTAL <br />HP <br />HORSEPOWER <br />HPC <br />HIGH PRESSURE CONDENSATE <br />HR <br />HOUR <br />HVAC <br />HEATING, VENTILATING AND AIR CONDITIONING <br />HPU <br />HEAT PUMP UNIT <br />HTG <br />HEATING <br />HPV <br />HIGH POINT VENT <br />ID <br />INSIDE DIAMETER <br />IE <br />INVERT ELEVATION <br />IGV <br />INLET GUIDE VANE <br />INSUL <br />INSULATION <br />IN <br />INCHES <br />KW <br />KILOWATT <br />KVA <br />KILOVOLT —AMPERE <br />LAT <br />LEAVING AIR TEMPERATURE ('F) <br />LBS, # <br />POUNDS <br />LWT <br />LEAVING WATER TEMPERATURE ('F) <br />MA <br />MIXED AIR <br />MAX <br />MAXIMUM <br />MBH <br />HEAT CAPACITY BTU PER HOUR X 1000 <br />MCC <br />MOTOR CONTROL CENTER <br />MECH <br />MECHANICAL <br />MIN <br />MINIMUM <br />MOV <br />MOTOR OPERATED VALVE <br />MTD, MTG <br />MOUNTED, MOUNTING <br />NC <br />NORMALLY CLOSED <br />GENERAL NOTES <br />NIC <br />NOT IN CONTRACT <br />NO <br />NORMALLY OPEN / NUMBER <br />NTS <br />NOT TO SCALE <br />1. <br />DESIGNATES EQUIPMENT APPEARING ON <br />NPSH <br />NET POSITIVE SUCTION HEAD <br />MECHANICAL EQUIPMENT SCHEDULES. <br />CA <br />OUTSIDE AIR <br />2. <br />SEE DRAWING M1d FOR ADDITIONAL MECHANICAL <br />OBD <br />OPPOSED BLADE DAMPER <br />LEGENDS AND ABBREVIATIONS. <br />OF <br />OVERFLOW <br />OS&Y <br />OUTSIDE SCREW AND YOKE <br />3. <br />SEE CONTROL SCHEMATIC(S) FOR ADDITIONAL <br />OD <br />OUTSIDE DIAMETER <br />ABBREVIATIONS AND SYMBOLS RELATING TO CONTROL <br />OVHD <br />OVERHEAD <br />SYSTEMS. <br />PBD <br />PARALLEL BLADE DAMPER <br />4. <br />DIFFUSER SYMBOLS WITHOUT AIR FLOW DIRECTION <br />PD/oP <br />PRESSURE DROP OR DIFFERENTIAL PRESSURE <br />ARROWS INDICATE AIR FLOW IN ALL DIRECTIONS (TWO <br />PDI <br />PLBG. & DRAINAGE INSTITUTE <br />DIRECTIONS FOR LINEAR DIFFUSERS). AIR FLOW ARROWS <br />POC <br />POINT OF CONNECTION <br />ARE USED TO INDICATE DESIRED AIR FLOW DIRECTIONS <br />POS <br />POSITION <br />IN OTHER CASES. <br />PRESS <br />PRESSURE <br />PRV <br />PRSSURE REGULATING VALVE <br />5. <br />SOME ABBREVIATIONS AND SYMBOLS INCLUDED IN THIS <br />PS <br />PRESSURE SWITCH <br />LEGEND MAY NOT BE FOUND ON ANY DRAWINGS. THEY <br />PSIG <br />PRESSURE — POUNDS PER SQUARE INCH, GAUGE <br />ARE INCLUDED HERE AS PART OF A STANDARD LEGEND <br />PSV <br />PRESSURE RELIEF (SAFETY) VALVE <br />AND MAY BE UTILIZED IN THE FUTURE. <br />RA <br />REVERSE ACTING (CONTROLLER) / RETURN AIR <br />RECT <br />RECTANGULAR <br />REF <br />REFERENCE <br />REFERENCE <br />DRAWINGS <br />REV <br />REVISED <br />RH <br />RELATIVE HUMIDITY <br />RM <br />ROOM <br />ROT <br />ROTATION <br />RPM <br />REVOLUTIONS PER MINUTE <br />ROD <br />REQUIRED <br />RTN <br />RETURN <br />SA SUPPLY AIR <br />SCFM CUBIC FEET OF AIR, AT STANDARD CONDITIONS <br />SHC SENSIBLE HEAT CAPACITY <br />SHF SENSIBLE HEAT FACTOR <br />SHT SHEET <br />SO SCREENED OPENING <br />SOV SOLENOID OPERATED VALVE <br />SP STATIC PRESSURE <br />SQ SQUARE <br />SS STAINLESS STEEL <br />STL STEEL <br />STRUC STRUCTURAL <br />SW SOCKET WELD <br />SUCT SUCTION CONSTRUCTION NOTES <br />SV SAFETY RELIEF VALVE <br />TDH <br />TOTAL DYNAMIC HEAD (FEET OF WATER) <br />TEMP <br />TEMPERATURE <br />TH <br />TOTAL HEAD (FEET OF WATER) <br />THC <br />TOTAL HEAT CAPACITY <br />THD <br />TOP HORIZONTAL DISCHARGE <br />THIRD <br />THREADED <br />TOD <br />TOP OF DUCT <br />TOS <br />TOP OF STEEL <br />TOP <br />TOP OF PIPE <br />TP <br />TOTAL PRESSURE <br />TS <br />TEMPERATURE SWITCH <br />TSP <br />TOTAL STATIC PRESSURE <br />TV <br />TURNING VANE <br />TYP <br />TYPICAL <br />UBD UP BLAST DISCHARGE <br />VAV <br />VARIABLE <br />AIR VOLUME <br />VD <br />VOLUME <br />DAMPER <br />VP <br />VELOCITY <br />PRESSURE <br />VERT <br />VERTICAL <br />VTA <br />VENT TO <br />ATMOSPHERE <br />VTR <br />VENT THROUGH ROOF <br />WB WET BULB TEMPERATURE <br />WG WATER GAUGE (INCHES OF WATER) <br />W/ WITH <br />WCO WALL CLEAN OUT <br />WHA WATER HAMMER ARRESTOR <br />FOR REFERENCE ONLY <br />FACILITY DESIGN BY FS i DATE 06.27.2022 <br />SYM <br />REVISION <br />BY <br />APPROVED <br />DATE <br />SYM <br />REVISION <br />BY <br />APPROVED <br />DATE <br />® <br />BOE//VO <br />THIS C DESIGN BAND/ R <br />SPECIFICATION IS APPROVED <br />URAWN <br />DAIL <br />07 22 96 <br />SUBTITLE <br />HVAC LEGEND <br />CURRENT REVISION <br />12727720 <br />SYMBOL <br />DATE <br />12.11.13 <br />— <br />40-51 AS—BUILTS J 964058-01 <br /># <br />CANADA <br />07.22.96 <br />CCHB.RECKED <br />M.C.S. <br />07.22.96 <br />SHEET <br />M 1 c <br />A <br />OBSERVATION TOWER HVAC UPGRADES 12727720 <br />SAZAN/RO <br />12.11.13 <br />ENGINEER <br />Q.C. <br />07.22.96 <br />TITLE <br />OBSERVATION TOWER HVAC UPGRADES <br />BUILDING 40-51 <br />MECHANICAL MASTER EVERETT, WA <br />APPROVED BY <br />DEPT. <br />DATE <br />CHECKED <br />Q.C. <br />07.22.96 <br />JOB NO. <br />COMPND. <br />APPROVED <br />APPROVED <br />DII No. 40-051—M1c <br />