MECHANICAL PIPING LEGEND <br />GENERAL <br />SYMBOL <br />DESCRIPTION <br />—1 j- <br />BREAK IN PIPE <br />I <br />CROSSING LINES, NO CONNECTION <br />DIRECTION OF FLOW <br />SLOPE <br />DIRECTION OF SLOPE, DOWN <br />gig <br />EQUIPMENT MARK NUMBER <br />rEXIST <br />EXISTING WORK <br />EXISTING TO BE REMOVED <br />— — <br />HIDDEN OR BELOW GRADE <br />IN -LINE RECIRCULATING PUMP <br />—� <br />INSULATED PIPE <br />—� <br />INSULATED PIPE WITH ELECTRIC HEAT TRACING <br />NEW WORK <br />*POC <br />POINT OF CONNECTION <br />k?— <br />PUMP <br />FIXTURES <br />SYMBOL <br />DESCRIPTION <br />O <br />CIRCULAR WASHFOUNTAIN <br />DF <br />DRINKING FOUNTAIN <br />EWC <br />ELECTRIC WATER COOLER <br />EWCH <br />ELECTRIC WATER COOLER FOR HANDICAPPED <br />FD <br />FLOOR DRAIN <br />O❑ FS <br />FLOOR SINK <br />Q lAV <br />LAVATORY, ROUND COUNTER MOUNT <br />❑O LAV <br />LAVATORY, RECTANGULAR COUNTER OR WALL MOUNT <br />OO RD (01FD) <br />ROOF DRAIN (OVERFLOW DRAIN - ROOF) <br />EWF <br />SAFETY EYE WASH FOUNTAIN <br />® SSEW <br />SAFETY SHOWER AND EYE WASH <br />Q <br />SEMI -CIRCULAR WASHFOUNTAIN <br />�SS <br />SERVICE SINK, FLOOR MOUNT <br />�SS <br />SERVICE SINK, WALL HUNG <br />® <br />SHOWER STALL AND FIXTURE <br />L! <br />UR <br />URINAL, WALL HUNG <br />C:::)WC <br />WATER CLOSET, FLUSH VALVE, WALL HUNG <br />0 WC <br />WATER CLOSET, FLUSH VALVE, FLOOR MOUNT <br />0 7D <br />TRENCH DRAIN <br />WASTE FITTINGS <br />SYMBOL <br />DESCRIPTION <br />1/4 BEND <br />CO <br />CLEAN OUT, EXPOSED <br />0 <br />CLEAN OUT, FLOOR <br />WCO <br />CLEAN OUT, WALL <br />❑ <br />FFD <br />FUNNEL FLOOR DRAIN <br />2 FUD <br />FUNNEL DRAIN <br />LATERAL <br />® <br />TRENCH DRAIN <br />QO WR <br />WASTE RECEPTOR, ROOF <br />RICO <br />WYE AND 1/8 BEND, SHOWN WITH CLEAN OUT <br />PIPE IDENTIFICATION <br />SYMBOL <br />DESCRIPTION <br />—A— <br />COMPRESSED AIR, PLANT <br />—AR— <br />ARGON GAS <br />—AW— <br />ACID WASTE <br />— C— <br />CONDENSATE RETURN (GRAVITY) <br />—CD— <br />CHEMICAL DRAIN <br />—CF— <br />CHEMICAL FEED <br />—CHWR— <br />CHILLED WATER RETURN <br />—CHWS— <br />CHILLED WATER SUPPLY <br />—CLD— <br />CLEAR WATER DRAIN <br />—CLWR— <br />COOLING WATER RETURN <br />—CLWS— <br />COOLING WATER SUPPLY <br />—CRV— <br />CORROSION RESISTANT VENT <br />—CRW— <br />CORROSION RESISTANT WASTE <br />—CTFR— <br />COOLING TOWER FILTER RETURN <br />—CTFS— <br />COOLING TOWER FILTER SUPPLY <br />—CTWR— <br />COOLING TOWER WATER RETURN <br />—CTWS— <br />COOLING TOWER WATER SUPPLY <br />—CW— <br />DOMESTIC COLD WATER <br />_DI— <br />DEIONIZED WATER <br />—DW— <br />DISTILLED WATER <br />—F— <br />FIRE LINE, AHEAD OF ALARM VALVE <br />—FH— <br />FIRE HOSE CABINET PIPING <br />—FOR— <br />FUEL OIL RETURN <br />— FOS— <br />FUEL OIL SUPPLY <br />— FOV— <br />FUEL OIL VENT <br />— G— <br />NATURAL GAS <br />— GN2— <br />GASEOUS NITROGEN <br />— HGD— <br />REFRIGERANT HOT GAS DISCHARGE <br />— HPC— <br />CONDENSATE, STEAM (HIGH PRESSURE) <br />— HPR— <br />CONDENSATE RETURN (HIGH PRESSURE) <br />— HPS— <br />STEAM SUPPLY (HIGH PRESS, 125-250 PSIG) <br />—HPWS— <br />HEAT PUMP WATER SUPPLY <br />—HPWR— <br />HEAT PUMP WATER RETURN <br />— HW— <br />DOMESTIC HOT WATER SUPPLY <br />— HWC— <br />DOMESTIC HOT WATER CIRCULATING <br />—HWR— <br />HEATING WATER RETURN <br />—HWS— <br />HEATING WATER SUPPLY <br />—IA — <br />INSTRUMENT AIR <br />—ID— <br />INDIRECT DRAIN <br />—IW — <br />INDUSTRIAL WASTE <br />—LN2— <br />LIQUID NITROGEN <br />—LPC— <br />CONDENSATE, STEAM (LOW PRESSURE) <br />—LPG — <br />LIQUID PETROLEUM GAS <br />— LIPS — <br />STEAM SUPPLY (LOW PRESS, 0-15 PSIG) <br />— MPC— <br />CONDENSATE, STEAM (MEDIUM PRESSURE) <br />—MPS— <br />STEAM SUPPLY (MEDIUM PRESS, 15-125 PSIG) <br />—OFD— <br />OVERFLOW DRAIN <br />—PCWS— <br />PROCESS COOLING WATER SOURCE <br />—PCWR— <br />PROCESS COOLING WATER RETURN <br />—PR— <br />CONDENSATE RETURN (PUMPED) <br />—PW— <br />PROCESS WATER <br />—RD— <br />ROOF DRAIN <br />PIPE IDENTIFICATION <br />SYMBOL <br />DESCRIPTION <br />— RDS— <br />REFRIGERANT DISCHARGE <br />—RHG— <br />REFRIGERANT HOT GAS <br />—RL— <br />REFRIGERANT LIQUID <br />—RS— <br />REFRIGERANT SUCTION (GAS) <br />— RWL— <br />RAIN WATER LEADER <br />—S— <br />SPRINKLER LINE <br />—SSW— <br />SAFETY SHOWER WATER <br />—SSWR— <br />SAFETY SHOWER WATER RETURN <br />— SAN— <br />SANITARY WASTE ABOVE GRADE <br />OR FLOOR <br />--SAN-- <br />SANITARY WASTE BELOW GRADE <br />OR FLOOR <br />—SPD— <br />SUMP PUMP DISCHARGE <br />— STM— <br />STEAM SUPPLY <br />— RWL— <br />STORM DRAIN ABOVE GRADE OR <br />FLOOR <br />--STS-- <br />STORM DRAIN BELOW GRADE OR <br />FLOOR <br />--- TP --- <br />TRAP PRIMER <br />--- V-- <br />VENT <br />— VAC— <br />VACUUM <br />— VPD— <br />VACUUM PUMP DISCHARGE <br />PIPE FITTINGS <br />SYMBOL <br />DESCRIPTION <br />BELL & SPIGOT <br />11 <br />BLIND FLANGE <br />BUSHING <br />--JUUL-- <br />EXPANSION JOINT <br />FLANGED FITTING <br />FLEXIBLE PIPE CONNECTION <br />HB <br />HOSE BIBB <br />'FHB <br />HOSE BIBB - NON FREEZE <br />PIPE ANCHOR <br />PIPE CAP SCREWED OR SOLDER JOINT <br />PIPE CAP, WELDED OR GROOVED <br />~ <br />PIPE CROSS <br />SR <br />PIPE ELBOW, 90' SHORT RADIUS <br />PIPE ELBOW, 90' LONG RADIUS <br />PIPE ELBOW, REDUCING <br />�k <br />PIPE ELBOW, 45' <br />�O <br />PIPE ELBOW, TURNED UP OR TOWARD <br />PIPE ELBOW, TURNED DOWN OR AWAY <br />= <br />PIPE GUIDE <br />PIPE HANGER <br />X <br />I Y <br />PIPING MATERIAL CHANGE, X TO Y <br />PIPE PLUG <br />PIPE REDUCER CONCENTRIC <br />PIPE REDUCER ECCENTRIC <br />t <br />PIPE SUPPORT <br />~ <br />PIPE TEE, STRAIGHT <br />F— <br />PIPE TEE, UP OR TOWARD <br />H— <br />PIPE TEE, DOWN OR AWAY <br />SCREWED FITTING OR AS SPECIFIED <br />f <br />SEISMIC HANGER <br />SOLDERED FITTING <br />PIPE FITTINGS <br />SYMBOL <br />DESCRIPTION <br />�f <br />SOLVENT CEMENT <br />LI <br />SPRING HANGER <br />UNION, FLANGED <br />----i F-- <br />UNION, SCREWED <br />0o- <br />WELDED FITTING <br />PIPING SPECIALTIES <br />SYMBOL <br />DESCRIPTION <br />2 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR <br />3 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR <br />0/0 <br />AIR DROP - HOSE, SIMPLEX / DUPLEX <br />e /® <br />AIR OUTLET - HARD PIPE, SIMPLEX / DUPLEX <br />Ca <br />ANGLE GLOBE VALVE, ELEVATION / PLAN <br />AUTOMATIC FLOW CONTROL VALVE <br />NUMBER INDICATES GPM <br />�AAV <br />AUTOMATIC AIR VENT (WITH DRAIN) <br />BFP <br />BACKFLOW PREVENTER <br />BALANCE VALVE WITH METERING PORTS <br />BALANCE VALVE W/O METERING PORTS <br />B0F/B4F <br />BALL VALVE, OPEN / CLOSED <br />BUTTERFLY VALVE <br />COOLING COIL CHILLED WATER <br />FLOAT VALVE <br />FE <br />FLOWMETER, VENTURI TYPE <br />FLOWMETER ORIFICE <br />-0o-/ <br />GATE VALVE, OPEN / CLOSE <br />GATE VALVE, OUTSIDE SCREW AND YOKE <br />GATE VALVE, WITH HOSE CONNECTION <br />/ <br />GLOBE VALVE, OPEN / CLOSED <br />HEATING COIL <br />H✓H/ <br />LIFT CHECK VALVE <br />�MAV <br />MANUAL AIR VENT (WITH DRAIN) <br />MOTOR OPERATED VALVE <br />NEEDLE VALVE <br />© <br />NITROGEN DROP <br />NO <br />NITROGEN OUTLET <br />H— <br />PETCOCK <br />f H <br />PETE'S PLUG, WITH BALL VALVE <br />PLUG VALVE/STOP COCK <br />PRESSURE GAUGE WITH VALVE <br />PRESSURE REGULATING VALVE W/EXT PRESS TAP <br />PRESSURE REGULATING VALVE (SELF CONTAINED) <br />PRESSURE RELIEF VALVE / SAFETY VALVE <br />QUICK OPENING VALVE <br />QUICK CLOSING VALVE, FUSIBLE LINK <br />SOLENOID OPERATED VALVE <br />�T <br />STEAM TRAP <br />SWING CHECK VALVE WITH FLOW <br />VACUUM BREAKER <br />MOISTURE TRAP <br />S <br />SOLENOID OPERATED VALVE <br />PIPING SPECIALTIES <br />SYMBOL <br />DESCRIPTION <br />TEST PLUG <br />THERMOMETER, LINE MOUNT <br />THERMOMETER, SEPARABLE WELL MOUNT <br />T❑ <br />TRAP, FLOAT <br />TRAP SEAL PRIMER VALVE <br />UNCLASSIFIED VALVE <br />Q <br />VACUUM DROP (LAB VAC) <br />OV <br />VACUUM OUTLET (LAB VAC) HARD PIPED <br />VACUUM CLEANING OUTLET <br />VALVE BOX <br />VALVE IN RISER (TYPE SPECIFIED) <br />T <br />WATER HAMMER ARRESTOR <br />~ <br />WYE STRAINER (WITH DRAIN VALVE) <br />FIRE PROTECTION <br />SYMBOL <br />DESCRIPTION <br />t <br />2 WAY EARTHQUAKE BRACING <br />x <br />4 WAY EARTHQUAKE BRACING <br />In ALV_ <br />ALARM VALVE, WET <br />I& ASR <br />AUTOMATIC SPRINKLER RISER <br />01­— <br />DRY PIPE VALVE <br />ELECTRIC BELL <br />EXISTING SPRINKLER HEADS (TO REMAIN) <br />EXISTING SPRINKLER HEADS (REMOVE) <br />FHC <br />FIRE HOSE CABINET <br />FS <br />FIRE DEPARTMENT CONNECTION, WALL TYPE <br />ZTC V <br />FIRE DEPARTMENT CONNECTION, YARD TYPE <br />Li FDC <br />FIRE DEPARTMENT CONNECTION, FLUSH <br />FH <br />FIRE HYDRANT - 2 HOSE OUTLET <br />FH <br />FIRE HYDRANT - 2 HOSE OUTLET <br />AND PUMPER CONNECTION <br />❑FS <br />FLOW SWITCH <br />O <br />HALON SYSTEM AUTOMATIC DISCHARGE STATION <br />HALON SYSTEM, MANUAL DISCHARGE STATION <br />�oc <br />GROOVED COUPLING, GROOVED CAP <br />0 <br />MONITOR SWITCH <br />POST INDICATOR VALVE, YARD <br />SPRINKLER HEAD, DRY PENDENT <br />SPRINKLER HEAD, OVER AND UNDER <br />f <br />SPRINKLER HEAD, PENDENT, IN LINE, NEW <br />•T <br />SPRINKLER HEAD, PENDENT, OFFSET, NEW <br />SPRINKLER HEAD, SIDEWALL, PENDENT, NEW <br />S7 <br />SPRINKLER HEAD, SIDEWALL, UPRIGHT, NEW <br />0— <br />SPRINKLER HEAD, UPRIGHT, NEW <br />THRUST BLOCK <br />}WN <br />b <br />WALL INDICATOR VALVE, PLAN / ELEVATION <br />WMG <br />WATER MOTOR GONG <br />WELDING <br />SYMBOL <br />DESCRIPTION <br />ROOT OPENING CONTOUR SYMBOL GROOVE ANGLE, <br />DEPTH OF FILLING INCLUDED ANGLE <br />FINISH SYMBOL OF COUNTERSINK <br />FOR PLUG AND FOR PLUGWELD <br />SLOT WELDS <br />EFFECTIVE LENGTH OF WELD <br />THROAT F PITCH (CENTER TO <br />SIZE OR CENTER SPACING) <br />A OF WELDS <br />STRENGTH FOR <br />CERTAIN WELDS R FIELD WELD SYMBOL <br />ARRT S <br />{ o -8 L— P REFERENCE LINE <br />(E) <br />N TO ARROW SIDE <br />�-1 OR ARROW SIDE <br />o 0� MEMBER OF JOINT <br />m �N J} <br />(N) <br />WELD ALL AROUND <br />SYMBOL <br />ELEMENTS IN THIS AREA REFERENCE LINE <br />REMAIN AS SHOWN WHEN <br />TAIL AND ARROW ARE NUMBER OF SPOT OR <br />((BASIC <br />REVERSED PROJECTION WELDS <br />WELD SYMBOL OR <br />DETAIL REFERENCE <br />TAIL MAY BE OMMITTED WHEN <br />REFERENCE ENCE IS NOT USED <br />SPECIFICATIONS, PROCESS <br />OR OTHER REFERENCE <br />p <br />BACK WELD <br />FILLET WELD <br />0 <br />PLUG OR SLOT WELD <br />SQUARE WELD <br />O <br />SPOT OR PROJECTION WELD <br />LEGEND <br />GENERAL NOTES <br />REFERENCE DRAWINGS <br />CONSTRUCTION NOTES <br />FOR REFERENCE ONLY <br />FACILITY DESIGN BY FS DATE 06 , 27 , 2022 <br />SYM <br />I REVISION <br />BY <br />APPROVED <br />DATE <br />SYM <br />REVISION <br />BY <br />APPROVED <br />DATE <br />BOE//VO ® <br />ACCEPTABILITY <br />THIS DESIGN AND/OR <br />SPECIFICATION IS APPROVED <br />URAWN <br />DAIL <br />SUBTITLE <br />PIPING LEGEND <br />CURRENT REVISION <br />19059373 <br />SYMBOL <br />D <br />DATE <br />10.14.16 <br />A <br />40-51 AS-BUILTS 964058-01 <br />CANADA <br />07.22.96 <br />CHECKED <br />SHEET <br />M 1 D <br />B <br />UTILITY RELOCATION 10739501 <br />SAZAN/FW <br />12.20.11 <br />ENGINEER <br />TITLE 40-051 HAZARDOUS CONTAINMENT COMPLIANCE <br />BUILDING 40-051 <br />MECHANICAL MASTER EVERETT, WA. <br />APPROVED BY <br />DEPT. <br />DATE <br />C <br />OBSERVATION TOWER HVAC UPGRADES 12727720 <br />SAZAN/RO <br />12.11.13 <br />CHECKED <br />JOB NO. 10739501 <br />COMP NO. <br />D <br />40-051 HAZARDOUS CONTAINMENT COMP.-100%IFC 19059373 <br />SAZAN/KB <br />10.14.16 <br />APPROVED <br />APPROVED <br />DWG NO. 40-051-M 1 <br />D <br />