3003 W CASINO RD BLDG 40-51 2023-06-15
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-51
>
3003 W CASINO RD BLDG 40-51 2023-06-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2023 9:04:59 AM
Creation date
6/15/2023 8:34:36 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-51
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXHAUST FAN SCHEDULE continued from 1 <br />Mb <br />EQUIPMENT <br />NUMBER <br />AREA <br />SERVED <br />DWG. <br />NO. <br />LOCATION <br />TOTAL <br />CFM <br />STATIC <br />PRESS. <br />IN. W.G <br />MAX <br />FAN <br />RPM <br />MIN <br />FAN <br />RPM <br />O.V. <br />FPM <br />DRIVE <br />ARR. <br />TIP <br />SPEED <br />FPM <br />MAX <br />BHP <br />MIN <br />BHP <br />H.P. <br />* <br />VAR. FREQ. <br />DRIVE ** <br />MIN. <br />FAN <br />CFM <br />MAX. <br />MOTOR <br />RPM <br />DRIVE <br />TYPE <br />FAN <br />TYPE <br />BASIS OF <br />DESIGN <br />WEIGHT <br />LBS <br />OUTLET <br />dBA <br />REMARKS/ <br />ACCESSORIES <br />EF-46 <br />NORTH BARREL ROOM <br />CONTINUOUS EXHAUST <br />RFM15 <br />COL. 5.5BH EL 115 <br />/ <br />1,360 <br />1.5 <br />1,960 <br />— <br />682 <br />CAW <br />BAU <br />5,388 <br />.2 <br />— <br />3 <br />NO <br />1,345 <br />1,725 <br />BELT <br />SWSI CCW BAU <br />GREENHECK 8—CSW—BI-41-10-0-3 <br />143 <br />68 <br />*,4-9 <br />FAN REMARKS: <br />* <br />ALL MOTORS 1HP AND ABOVE SHALL BE HIGH EFFICIENCY TYPE 460V/3PH/60H. ALL MOTORS <br />3/4 <br />HP AND LESS SHALL BE 120V/lPH/60HZ. <br />** <br />VARIABLE FREQUENCY DRIVE SUPPLIED BY ELECTRICAL CONTRACTOR <br />1. <br />TOTALLY ENCLOSED FAN —COOLED (TEFC) MOTOR, NON—FERROUS OR NON —SPARKING MATERIAL, <br />CLASS I, DIV 1, GROUP A, BEARINGS OUT OF AIR STREAM. <br />2. <br />480V/3PH MOTOR. <br />3. <br />PROVIDE LIFTING LUGS, ACCESS DOOR, DRAIN WITH PLUG, FLANGED INLET AND OUTLET, BASE <br />RAILS, <br />1" DEFLECTION ISOLATION (MASON INDUSTRIES), SHAFT SEAL, SHAFT GROUND RING. <br />4. <br />PROVIDE CLASS I, DIV. 1 CONSTRUCTION, BEARINGS OUT OF AIR STREAM, NEMA PREMIUM EFFICIENT <br />MOTOR, ALL ALUMINUM SCROLL WHEEL AND INLET CONE, MOTOR WITH B—CLASS INSULATION, WELDED SCROLL HOUSING, BACKWARD INCLINED WHEEL, INLET COLLAR, UL LISTING 705, 1" DRAIN CONNECTION, <br />STEEL WEATHER HOOD, PUNCHED OUTLET FLANGE. <br />5. PROVIDE ROOF STACK EXTENSION. SEE ROOF PLAN, RFM15, FOR STACK DIAMETER. PROVIDE SEISMIC RESTRAINTS AS INDICATED BY ASCE-7. <br />6. CONNECT FAN TO STANDBY POWER SUPPLY <br />7. FAN OPERATES CONTINUOUSLY. SHUT—OFF DAMPER NOT REQUIRED. DISCONNECT AND MOTOR STARTER BY ELECTRICAL. <br />8. FAN SHALL SHUT DOWN UPON ACTIVATION OF GLASS EMERGENCY SHUT—OFF SWITCH. <br />9. FAN SHALL OPERATE SIMULTANEOUSLY WITH AHU-22. (AHU-22 IS NOT ON STANDBY POWER) <br />LEGEND <br />GENERAL NOTES <br />REFERENCE DRAWINGS <br />CONSTRUCTION NOTES <br />FOR REFERENCE ONLY <br />FACILITY DESIGN BY FS DATE06.27.2022 <br />SYM <br />I REVISION <br />BY <br />APPROVED <br />DATE <br />SYM <br />REVISION <br />BY <br />APPROVED <br />DATE <br />BOE/A/� ® <br />THSC ESIGNBAND/ R <br />SPECIFICATION IS APPROVED <br />03.17.16 <br />" ..." <br />EQUIPMENT SCHEDULE <br />19059373 <br />"""""" <br />— <br />" .- <br />10.14.16 <br />- <br />40-051 HAZARDOUS CONTAINMENT COMP.-100%IFC 19059373 <br />SAZAN/KB <br />10.14.16 <br />CHECKED <br />SHEET <br />M 1 n <br />ENGINEER <br />TITLE 40-051 HAZARDOUS CONTAINMENT COMPLIANCE <br />BUILDING 40-5 1 1 <br />APPROVED BY <br />DEPT. <br />DATE <br />CHECKED <br />JOB N0. <br />94049.01 <br />COMP N0. <br />APPROVED <br />MECHANICAL MASTER <br />EVERETT, WA. <br />40-051—M1n <br />