My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Valdez Construction 6/12/2023
>
Contracts
>
Capital Contract
>
Capital Construction Contracts and Change Orders
>
Valdez Construction 6/12/2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2025 12:10:36 PM
Creation date
6/16/2023 10:20:25 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Valdez Construction
Approval Date
6/12/2023
Council Approval Date
5/10/2023
Department
Transportation Services
Department Project Manager
Vincent Bruscas
Subject / Project Title
Eclipse Mill Park Inductive Charging Infrastructure
Tracking Number
0003790
Total Compensation
$923,272.10
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
Document Relationships
Valdez Construction 10/10/2024 Change Order 2
(Contract)
Path:
\Records\City Clerk\Contracts\10 Years Then Transfer to State Archivist\2024
Valdez Construction 5/1/2024 Amendment 1
(Contract)
Path:
\Records\City Clerk\Contracts\10 Years Then Transfer to State Archivist\2024
Valdez Construction 5/5/2025 Change Order 3
(Contract)
Path:
\Records\City Clerk\Contracts\10 Years Then Transfer to State Archivist\2025
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
458
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
City of Everett 01 45 23 -2 <br /> Inductive Charging Infrastructure for Everett Transit <br /> 6. ASTM C231 -Standard Test Method for Air Content of Freshly Mixed Concrete <br /> by the Pressure Method. <br /> 7. ASTM C1314 - Standard Test for Compressive Strength of Masonry Prisms. <br /> 8. ASTM D1557 - Test Method for Moisture-Density Relations of Soils, and Soil- <br /> Aggregate Mixtures Using 10-lb. (4.54 kg) Rammer and 18-in. <br /> (457 mm) Drop. <br /> 9. ASTM C1077 - Practice for Laboratories Testing Concrete and Concrete <br /> Aggregates for Use in Construction and Criteria for Laboratory <br /> Evaluation <br /> 10. ASTM E329 - Practice for Use in the Evaluation of Testing and Inspection <br /> Agencies as Used on Construction. <br /> 11. ASTM E605 - Standard Test Methods for Thickness and Density of Sprayed Fire- <br /> Resistive Material (SFRM)Applied to Structural Materials. <br /> 12. ASTM E2174 - Standard Practice for On-Site Inspection of Installed Fire Stops <br /> D. Association of the Wall and Ceiling Industries International (AWCI): AWCI Technical <br /> Manual 12-B - Standard Practice for the Testing and Inspection of Field Applied Thin- <br /> Film Intumescent Fire-Resistive Materials; an Annotated Guide. Web Site <br /> http://www.awci.org. <br /> 1.3 REGULATORY REQUIREMENTS <br /> A. Conform to IBC Chapter 17 and building code authority having jurisdiction for <br /> requirements pertaining to structural tests and special inspections. <br /> B. Statement of Special Inspections: Prepared by Structural Engineer of Record, as shown <br /> on Structural Drawings, conforming to provisions of IBC Section 1705. <br /> C. Contactor's Statement of Responsibility: Conform to IBC Section 1706 for written <br /> statement of responsibility for construction of a main wind-force-resisting system or <br /> component and seismic-resisting system or component listed in Statement of Special <br /> Inspections. <br /> 1. Submit to building code official and Owner. <br /> 2. Submit to Architect for review, conforming to Section 01 33 00, and prior to <br /> submitting to building code official. <br /> 1.4 TESTING AND INSPECTION SERVICES <br /> A. Special Inspector Required by Code: <br /> 1. Employed by Owner. <br /> 2. Registered and approved by regulatory authority having local jurisdiction to <br /> conduct Special Inspections, testing, and laboratory services, required by IBC <br /> Chapter 17. <br /> 3. Qualified as ACI Concrete Inspector Level II or equivalent for concrete inspections. <br /> B. Geotechnical (Soils) Engineer: Employed by Owner to conduct Special Inspections, <br /> including construction observation and soils engineering services, for work pertaining to <br /> 01 45 23 - 2 TESTING AND INSPECTION SERVICES <br />
The URL can be used to link to this page
Your browser does not support the video tag.