Laserfiche WebLink
City of Everett 26 00 10 -20 <br /> Inductive Charging Infrastructure for Everett Transit <br /> a. Dimensioned concrete bases, outlines of equipment, conduit entries, and <br /> grounding equipment locations. <br /> b. If freight elevator must be used, indicate width and height of door and <br /> depth of car. Indicate if large equipment must be tipped to use elevator. <br /> c. Dimensioned working clearances and dedicated areas below and around <br /> electrical equipment where obstructions and tripping hazards are <br /> prohibited. <br /> 3. Reflected ceiling plans for entry floor and floor where equipment is located, <br /> drawn to scale, on which the following items shown and coordinated with each <br /> other, based on input from installers of the items involved: <br /> a. Support locations, type of support, and weight on each support. Locate <br /> structural supports for structure-supported raceways. <br /> b. Location of lighting fixtures, sprinkler piping and sprinklers, ducts and <br /> diffusers, and other obstructions, indicating available overhead clearance. <br /> c. Dimensioned working clearances and dedicated areas above and around <br /> electrical equipment where foreign systems and equipment are prohibited. <br /> H. Coordination Drawings for Large Equipment Outdoor Installations: <br /> 1. Utilities site plan, drawn to scale, showing heavy equipment or truck access <br /> paths for maintenance and replacement, with the following items shown and <br /> coordinated with each other, based on input from installers of the items involved: <br /> a. Fences and walls, dimensioned concrete bases, outlines of equipment, <br /> conduit entries, and grounding and bonding locations. <br /> b. Indicate clear dimensions for fence gates and wall openings. <br /> c. Indicate depth and type of ground cover, and locations of trees, shrubbery, <br /> and other obstructions in access path. <br /> d. Indicate clear height below tree branches, overhead lines, bridges, and <br /> other overhead obstructions in access path, or where cranes and hoists will <br /> be needed to handle large electrical equipment. <br /> e. Support locations, type of support, and weight on each support. Locate <br /> structural supports for structure-supported raceways. <br /> f. Dimensioned working clearances and dedicated areas around electrical <br /> equipment. <br /> Coordination Drawings for Duct Banks: <br /> 1. Show duct profiles and coordination with other utilities and underground <br /> structures. <br /> 2. Include plans and sections, drawn to scale, and show bends and locations of <br /> expansion fittings. <br /> 3.2 DELEGATED DESIGN OF STRUCTURAL PENETRATIONS <br /> A. Engage qualified structural professional engineer to design penetrations of structural <br /> masonry walls. <br /> B. Delegated Design Drawings for Structural Masonry Wall Penetrations: Where indicated <br /> on Drawings, provide reflected ceiling plan(s), supplemented by elevations, sections, <br /> and other details, drawn to scale, signed and sealed by a qualified structural <br /> 26 00 10 -20 SUPPLEMENTAL REQUIREMENTS FOR ELECTRICAL <br />