Search
Valdez Construction 6/12/2023
>
Contracts
>
Capital Contract
>
Capital Construction Contracts and Change Orders
>
Valdez Construction 6/12/2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2025 12:10:36 PM
Creation date
6/16/2023 10:20:25 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Valdez Construction
Approval Date
6/12/2023
Council Approval Date
5/10/2023
Department
Transportation Services
Department Project Manager
Vincent Bruscas
Subject / Project Title
Eclipse Mill Park Inductive Charging Infrastructure
Tracking Number
0003790
Total Compensation
$923,272.10
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
Document Relationships
Valdez Construction 10/10/2024 Change Order 2
(Contract)
Path:
\Records\City Clerk\Contracts\10 Years Then Transfer to State Archivist\2024
Valdez Construction 5/1/2024 Amendment 1
(Contract)
Path:
\Records\City Clerk\Contracts\10 Years Then Transfer to State Archivist\2024
Valdez Construction 5/5/2025 Change Order 3
(Contract)
Path:
\Records\City Clerk\Contracts\10 Years Then Transfer to State Archivist\2025
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
458
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
City of Everett 26 05 19 -4 <br /> Inductive Charging Infrastructure for Everett Transit <br /> 4. Initial Infrared Scanning: After Substantial Completion, but before Final <br /> Acceptance, perform an infrared scan of each splice in conductors No. 3 AWG <br /> and larger. Remove box and equipment covers so splices are accessible to <br /> portable scanner. Correct deficiencies determined during the scan. <br /> a. Instrument: Use an infrared scanning device designed to measure <br /> temperature or to detect significant deviations from normal values. Provide <br /> calibration record for device. <br /> b. Record of Infrared Scanning: Prepare a certified report that identifies <br /> switches checked and that describes scanning results. Include notation of <br /> deficiencies detected, remedial action taken, and observations after <br /> remedial action. <br /> 5. Follow-up Infrared Scanning: Perform an additional follow-up infrared scan of <br /> each switch 11 months after date of Substantial Completion. <br /> B. Cables will be considered defective if they do not pass tests and inspections. <br /> C. Prepare test and inspection reports to record the following: <br /> 1. Procedures used. <br /> 2. Results that comply with requirements. <br /> 3. Results that do not comply with requirements, and corrective action taken to <br /> achieve compliance with requirements. <br /> END OF SECTION 260519 <br /> 26 05 19 -4 LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES <br />
The URL can be used to link to this page
Your browser does not support the video tag.