City of Everett 26 05 43 - 5 <br /> Inductive Charging Infrastructure for Everett Transit <br /> D. Underground Ducts Crossing Paved Paths Walks and Driveways: [PVC-80] [PVC-40] <br /> [direct buried] [encased in reinforced concrete]. <br /> E. Underground Ducts Crossing Roadways and Railroads: [PVC-80] [PVC-40], encased <br /> in reinforced concrete. <br /> F. Stub-ups: Concrete encased, [PVC-80] [PVC-40] [ERMC-S] [ERMC-S-PVC] [IMC]. <br /> 3.2 FIELD QUALITY CONTROL <br /> A. Acceptance Testing Preparation: <br /> B. Tests and Inspections: <br /> 1. Demonstrate capability and compliance with requirements on completion of <br /> installation of underground duct, duct bank, and utility structures. <br /> 2. Pull solid aluminum or wood test mandrel through duct to prove joint integrity and <br /> adequate bend radii, and test for out-of-round duct. Provide minimum 12 inches <br /> long mandrel equal to duct size minus 1/4 inch. If obstructions are indicated, <br /> remove obstructions and retest. <br /> 3. Test manhole and handhole grounding to ensure electrical continuity of <br /> grounding and bonding connections. Measure and report ground resistance as <br /> specified in Section 260526 "Grounding and Bonding for Electrical Systems." <br /> C. Nonconforming Work: <br /> 1. Underground ducts, raceways, and structures will be considered defective if they <br /> do not pass tests and inspections. <br /> 2. Correct deficiencies and retest as specified above to demonstrate compliance. <br /> D. Field Quality-Control Reports: Collect, assemble, and submit test and inspection <br /> reports. <br /> E. Manufacturer Services: Engage factory-authorized service representative to support <br /> field tests and inspections. <br /> 1. Manufacturer's Field Reports for Field Quality-Control Support: Prepare and <br /> submit report after each visit by factory-authorized service representative, <br /> documenting activities performed at Project site. <br /> 3.3 CLEANING <br /> A. Pull leather-washer-type duct cleaner, with graduated washer sizes, through full length <br /> of duct until duct cleaner indicates that duct is clear of dirt and debris. Follow with <br /> rubber duct swab for final cleaning and to assist in spreading lubricant throughout <br /> ducts. <br /> B. Clean internal surfaces of manholes, including sump, and building interiors affected by <br /> Work. <br /> 1. Sweep site, removing dirt and debris. <br /> 2. Remove foreign material. <br /> 26 05 43 - 5 UNDERGROUND DUCTS AND RACEWAYS FOR ELECTRICAL SYSTEMS <br />