Laserfiche WebLink
Model: FSH-2, FSH-2A-99 Operation <br /> 4.03 Nood Filter Alarms <br /> 4.03.1 l3affle or Charcoal [or NEPA] Filter Missing <br /> If either, or all, of the baffle, charcoal, HEPA filters is not in place, or not positioned correctly,the red <br /> [FILTER MISSING] light will turn ON. Power to the fryer under the hood is shutdown until the <br /> condition is corrected;the amber[FRYER POWER] light turns OFF. No audible alarm will sound. <br /> • Hood fan continues running. <br /> • Check to confirm that all filters are in place. See Sections 4.02.3-4.02.5-4.02.6, Filter <br /> Installations. <br /> • Remove and reinstall filters to ensure that they are seated properly in the guides and are pushed <br /> fully into the filter compartment so that the cover fits properly. Each filter must also actuate a <br /> proofing switch. Charcoal and HEPA filter switches are in the rear wall. Baffle filter switch is a <br /> lever switch on the right side under the hood. <br /> 4.03.2 13affle or Charcoal [or NEPA] Filter Clogged <br /> If any filter becomes clogged, or there are other conditions that obstruct airflow, causing it to fall <br /> below the minimum required to provide effective capture of cooking vapors, power to the fryer under <br /> hood is shutdown,the amber [FRYER POWER] light turns OFF and a constant(steady)tone audible <br /> alarm sounds until corrective action is taken. <br /> • Hood fan continues running. <br /> • Clean the baffle filter, see Section 4.04.1, Baffle Filter Cleaning. <br /> • Replace charcoal or HEPA filter with fresh new, see Section 4.03.5, Charcoal Filter Maintenance. C-NGE NOW <br /> • Inspect Hood plenum to ensure that no other obstructions exist. <br /> • Check the hood exhaust outlet and be sure that nothing is obstructing it or the surrounding area. SNOOZE <br /> NOTE: There is no indicator light for clogged filter,only an audible alarm tone. <br /> 32 <br />