My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3900 BROADWAY BASE FILE 2023-06-26
>
Address Records
>
BROADWAY
>
3900
>
BASE FILE
>
3900 BROADWAY BASE FILE 2023-06-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/26/2023 2:31:47 PM
Creation date
6/21/2023 6:07:48 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3900
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
138
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Model: FSH-2, FSH-2A-99 Cleaning & Maintenance <br /> 5.03.1 lVionthly Nood Interlock Inspection (Coil Generally be Performed by User) <br /> Hood design incorporates various interlock switches to ensure that the unit will shutdown if certain conditions exist which <br /> are not consistent with safe and effective operation. The interlocks should be inspected and tested MONTHLY as described <br /> below. Use the Maintenance&Service Log to record completion of testing. If problems are detected,contact GILES or an <br /> authorized service provider. <br /> 1. Door Interlock Test: Start hood. With hood running, unlatch and slightly lift the bottom lip of the filter access <br /> cover to confirm that hood powers OFF when cover is lifted and the fryer under the hood turns OFF, or cannot be <br /> turned ON.b <br /> 2. Baffle Filter Test: Remove baffle filter then turn ON hood power. Verify that the red [FILTER MISSING] light <br /> turns ON and the [FRYER POWER] light turns OFF. Check to ensure that fryer under hood will not turn ON. <br /> Reinstall the baffle filter. See Sections 4.02.2&4.02.3, Removal& Installation. <br /> 3. Charcoal (and HEPA) Filter Test: Same procedure as#2 except perform for the charcoal filter. Reinstall filter. <br /> See Sections 4.02.6,4.02.7, Removal& Installation. Same procedure applies for a HEPA filter, if equipped. <br /> 4. E.A.C. Filter Test(N/A for HEPA Filter Version): Same procedure as#2 except remove the E.A.C. collector <br /> cell, close and latch filter cover. Turn ON hood power. Verify that [WASH] light is ON, along with the amber <br /> [FRYER POWER] light. Wait approx. two (2) minutes. A beeping tone alarm should begin sounding. Shortly,the <br /> [FRYER POWER] light should turn OFF. Check to ensure that fryer under Hood will not turn ON. Reinstall the <br /> E.A.C. cell. See Section 4.02.4. &4.02.5, Removal& Installation. <br /> 5. Filter Clogged Test: Perform this test ONLY after installing new Charcoal Filter. Start hood normally and allow <br /> to run. Use cardboard or other material to completely block Hood exhaust outlet, holding it firmly in place so that <br /> no air is escaping. Within a few seconds, a continuous tone alarm should begin sounding and the [FRYER POWER] <br /> light should turn OFF. Check to ensure that fryer under Hood will not turn ON. Remove the obstruction; the <br /> alarm should silence and the [FRYER POWER] light should turn ON again. <br /> Should any of these tests fail to yield the described results, contact a factory-authorized service company and have the <br /> unit evaluated and repaired. Any Giles Manufacturer's Representative can provide information about nearby authorized <br /> service providers, or call GILES Services at 800-554-4537 for assistance in locating a Representative or service provider. <br /> 5.04 Fire Suppression , <br /> The self-contained fire extinguishing system in the hood must be maintained in accordance with the Standard for Wet <br /> Chemical Extinguishing Systems, NFPA 17A and with the instructions of the system installer. <br /> All inspection, maintenance,troubleshooting, repairs and general servicing of the fire extinguishing system must be <br /> performed by an authorized Ansul®Distributor/Dealer. Required maintenance activities are described in the subsequent <br /> sections. <br /> )ON- <br /> 42 <br />
The URL can be used to link to this page
Your browser does not support the video tag.