Laserfiche WebLink
LABEL 6 <br /> WARNINGLABEL 1 AT DIRECT-CURRENT EXPOSED RACEWAYS,CABLE TRAYS,COVERS AND <br /> WHERE ALL TERMINALS OF THE DISCONNECTINGS WARNING: PHOTOVOLTAIC ENCLOSURES OF JUNCTION BOXES,AND OTHER WIRING METHODS;SPACED <br /> • <br /> MEANS MAY BE ENERGIZED IN THE OPEN POSITION,A AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES,WALLS, <br /> ELECTRIC SHOCK HAZARD PARTITIONS,CEILINGS,OR FLOORS. <br /> • <br /> WARNING SIGN SHALL BE MOUNTED ON OR ADJACENT <br /> TERMINALS ON BOTH LINE AND TO THE DISCONNECTING MEANS. [NEC 690.31(G)(3&4)] <br /> LABEL 10 <br /> LABEL 7 <br /> LOAD SIDES MAY BE ENERGIZED IN [NEC 690.13(B)AND NEC 690.15(C)] SOLAR PV SYSTEM EQUIPPED BUILDINGS WITH PV SYSTEMS SHALL HAVE A PERMANENT MAIN PHOTOVOLTAIC <br /> LABEL LOCATED AT EACH SERVICE EQUIPMENT LOCATION 5 L A R <br /> THE OPEN POSITION WITH RAPID SHUTDOWN TO WHICH THE PV SYSTEMS ARE CONNECTED OR AT AN SERVICE DISCONNECT <br /> APPROVED READILY VISIBLE LOCATION AND SHALL INDICATE <br /> LABEL 2 THE LOCATION OF RAPID SHUTDOWN INITIATION DEVICES. Revolution Energy Systems Inc. <br /> WARNING THE LABEL SHALL INCLUDE A SIMPLE DIAGRAM OF A BUILDING 9981 West 190th St <br /> PERMANENT WARNING LABELS SHALL BE APPLIED TO TURN RAPID SHUTDOWN so nRe ecraic WITH A ROOF AND SHALL INCLUDE THE FOLLOWING WORDS: • • • <br /> ■ DISTRIBUTION EQUIPMENT. SWICH TO THE"OFF" PVPnNe�s <br /> THIS EQUIPMENT IS FED BY MULTIPLE [NEC 705.12(B)(3)(3)] POSITION TO SHUT DOWN THE TITLE"SOLAR PV SYSTEM IS EQUIPPED WITH Unit K Mokena IL 60448 <br /> PV SYSTEM AND REDUCE RAPID SHUTDOWN"SHALL UTILIZE CAPITALIZED • T: 708-995-1643 <br /> SOURCES. TOTAL RATING OF ALL SHOCK HAZARD IN ARRAY CHARACTERS WITH A MINIMUM HEIGHT OF 3/8 IN.IN <br /> OVERCURRENT DEVICES, EXCLUDING BLACK ON YELLOW BACKGROUND,AND THE REMAINING <br /> CHARACTERS SHALL BE CAPITALIZED WITH A MINIMUM EACH PV SYSTEM DISCONNECTING MEANS SHALL PLAINLY <br /> MAIN SUPPLY OVERCURRENT HEIGHT OF 3/16 IN.IN BLACK ON WHITE BACKGROUND. INDICATE WHETHER IN THE OPEN(OFF)OR CLOSED(ON) <br /> DEVICE, SHALL NOT EXCEED [NEC 690.56(B),690.4(D)AND 705.101 POSITION AND BE PERMANENTLY MARKED: <br /> AMPACITY OF BUSBAR. • ■ ■ EQUIPPED <br /> "PV SYSTEM DISCONNECT"OR EQUIVALENT. <br /> WITH RAPID ,• LABEL 8 [NEC 690.13(B),690.15 AND 705.20] SITE INFORMATION <br /> FOR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS JOHN LUKAS CHUBINSKY <br /> WARNING LABEL 3 TURN RAPID SHUTDOWN LEAVING THE ARRAY: <br /> A PERMANENT WARNING LABEL SHALL BE ® SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY <br /> APPLIED TO THE DISTRIBUTION EQUIPMENT SWITCH TO THE"OFF" I FROM SERVICE DISCONNECTING MEANS TO WHICH THE 2802 16TH STREET <br /> A!m T <br /> ADJACENT TO THE BACK-FED BREAKER FROM POSITION TO SHUT DOWN I— — PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE EVERETT,WA 98201 <br /> INVERTER OUTPUT CONNECTION THE INVERTER. CONDUCTORS OUTSIDE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN <br /> DO NOT RELOCATE THIS OVER [NEC 705.12(B)(3)(2)] THE WITHIN THE ARRAY REMAIN SWITCHES IF NOT AT THE SAME LOCATION. AC System Size:4.20 kW AC/4.20 kVA <br /> CURRENT DEVICE ENERGIZED IN SUNLIGHT [NEC 690.56(C)(1)(B)] DC System Size:5.60 kW DC <br /> Lat,47.9960114 <br /> LABELS Long,-122.1931020 <br /> LABEL 4 RAPID SHUTDOWN A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL (14)HANWHA Q.PEAK DUO L-G7.3(400W) <br /> Zh WARNING EQUIPMENT CONTAINING OVERCURRENT LOCATED ON OR NO MORE THAN 3 FT FROM THE SWITCH PV Modules <br /> DEVICES IN CIRCUITS SUPPLYING POWER TO ASWITCH FOR THAT INCLUDES THIS WORDING.THE LABEL SHALL BE <br /> DUAL POWER SUPPLY BUSBAR OR CONDUCTOR SUPPLIED FROM REFLECTIVE,WITH ALL LETTERS CAPITALIZED AND HAVING A (2) HOYMILES HM-120ON(240V) <br /> MULTIPLE SOURCES SHALL BE MARKED TOSOLAR PV SYSTEM MINIMUM HEIGHT OF 3/8 IN.,IN WHITE ON RED (2) HOYMILES HM-60ON(240V) <br /> SOURCES: UTILITY GRID AND PV INDICATE THE PRESENCE OF ALL SOURCES BACKGROUND. (2) HOYMILES HM-30ON(240V) <br /> SOLAR ELECTRIC SYSTEM [NEC 705.101 [NEC 690.56(C)] Inverter(s) <br /> LABEL 5 MAIN SERVICE PANEL <br /> SNOHOMISH COUNTY PUD <br /> PHOTOVOLTAIC AC DISC• ALL INTERACTIVE SYSTEM(S)POINTS OF _j <br /> INTERCONNECTION WITH OTHER SOURCES SHALL <br /> BE MARKED AT AN ACCESSIBLE LOCATION AT THE LABELING DIAGRAM: <br /> • ■ 17.50 A DISCONNECTING MEANS AS A POWER SOURCE O O EXISTING SUB PANEL PV COMBINER <br /> ■ INVERTER(5) <br /> AND WITH THE RATED AC OUTPUT CURRENT AND (IF WHERE POINT OF SUBPANEL- <br /> NOMINAL OPERATING AC VOLTAGE: 240 V THE NOMINAL OPERATING AC VOLTAGE. O O INTERCONNECTION IF USED TO COMBINE <br /> [NEC 690.54] Q <br /> IS MADE) AC DISCONNECT PV OUTPUT CIRCUITS <br /> O O O O O O <br /> (1)BUILDINGS WITH MORE THAN ONE RAPID SHUTDOWN TYPE.FOR BUILDINGS THAT HAVE PV SYSTEMSO <br /> WITH BOTH RAPID SHUTDOWN TYPES OR A PV SYSTEM WITH A RAPID SHUTDOWN TYPE AND A PV SYSTEM O 10 O O O <br /> WITH NO RAPID SHUTDOWN,A DETAILED PLAN VIEW DIAGRAM OF THE ROOF SHALL BE PROVIDED SHOWING O JUNCTION BOX <br /> EACH DIFFERENT PV SYSTEM AND A DOTTED LINE AROUND AREAS THAT REMAIN ENERGIZED AFTER THE RAPID <br /> � OR COMBINER BOX <br /> SHUTDOWN SWITCH IS OPERATED. F <br /> oc <br /> LABELING NOTES: <br /> O O O O <br /> 1.LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO DETERMINE EXACT (ONLY IF PV (ONLY IF PV <br /> INTERCONNECTION INTERCONNECTION <br /> REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. CONSISTS OF LOAD CONSISTS OF LOAD <br /> 2.LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRIC CODE,OSHA STANDARD 19010.145,ANSI SIDE BREAKER) SIDE BREAKER) DRAWN BY:J EROME JAPAL <br /> Z535. <br /> 3.MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. INTEGRATED DC DISCONNECT DATE: <br /> 4.LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED[NEC 110.21(B)(3)] *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY.NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED.LABEL LOCATIONS 4/3/2023 <br /> 5.LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8",WHITE ON RED BACKGROUND;REFLECTIVE,AND PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE. <br /> PERMANENTLY AFFIXED[IFC 605.11.1.11 LABELS - PV07 <br />