Laserfiche WebLink
S L A R <br /> CAUTION Revolution Energy Systems Inc. <br /> 9981 West 190th St <br /> POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR Unit K Mokena IL 60448 <br /> ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: T: 708-995-1643 <br /> N <br /> SITE INFORMATION <br /> JOHN LUKAS CHUBINSKY <br /> 2802 16TH STREET <br /> MAIN DISTRIBUTION <br /> UTILITY DISCONNECT EVERETT,WA 98201 <br /> AC System Size:4.20 kW AC/4.20 kVA <br /> UTILITY METER DC System Size:5.60 kW DC <br /> AC DISCONNECT <br /> LOAD CENTER Lat,47.9960114 <br /> Long,-122.1931020 <br /> (14)HANWHA Q.PEAK DUO L-G7.3(400W) <br /> PV Modules <br /> (2) HOYMILES HM-120ON (240V) <br /> (2) HOYMILES HM-60ON (240V) <br /> (2) HOYMILES HM-30ON (240V) <br /> Inverter(s) <br /> SNOHOMISH COUNTY PUD <br /> PV ARRAY <br /> 2802 16TH STREET, EVERETT, WA 98201 <br /> DIRECTORY <br /> PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE <br /> SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. <br /> (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: <br /> NEC 690.56(B)&(C), [NEC 705.10]) <br /> DRAWN BY:JEROME JAPAL <br /> DATE: <br /> 4/3/2023 <br /> PLACARD - PV08 <br />